My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7760 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7760 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:51:17 PM
Creation date
2/24/2025 9:36:23 AM
Metadata
Fields
Template:
Building Plans
Street #
7760
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
2580
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />L ALL MECHANICAL EQUIPMENT 614ALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL. BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 'ITH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC TTH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED 5UPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO PBC TTH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 'ITH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -GUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS ALL, HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC ITH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />Il. DRYER BOOSTER TO BE A FANTECI-I DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN ! LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-TWRU AIR GRILL <br />NOTE: <br />ALL HVAC TO NAVE PROPER <br />PHIS W/ DRAINS <br />1010 <br />- EXTERIOR WALL <br />PLENUM*MECHANICAL <br />AIR RETURN <br />ON AND LIQUID <br />SECURE STRAP TO CONC. CONDENSERW/ <br />AIR SUPPLYGERANT <br />LINES <br />(2)-3/I6'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />AIR HANDLERRIOR <br />WALL <br />VC CONDENSATE DRAIN LINE <br />SECURE STRAP TO UNIT W/ (2) <br />EVAP. TRAYLEEVE <br />TO LINES BELOW SLAB <br />4' CONCRETE SLAB #&XI 1/4' SHT. MTL. SCREW6CONDENSER <br />REFRIGERANT TO <br />UNIT <br />PLATFOR'1CONDENSING <br />IT <br />UNITTRAP <br />DRAIN LINE AND TERMINATE <br />CONNECTION <br />IN AN APROVEI DRAIN, PER <br />TO PAD <br />) <br />FBCR 1TH EDITION (2020)NOTE: <br />MAIN COND. DRAIN 3/4' DIA <br />BLDG. CODE <br />SECTION 3012.4 <br />OVER HEAD • 12' FROM STRUCTURE <br />HVAC <br />DRAINS <br />SCORATED NICKEL FIN. FLOOR <br />BRONZE FL. PL, OR WALL <br />COUNTERSUNKPLUG <br />GA. <br />.. <br />SEE SPEC. <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K J05AM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />(I)FLOOR SLAB CLEAN -OUT (TYP.T) <br />FIN. GRADE <br />OR PAVING <br />I'-8'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />2 EXT. GROUND CLEAN -OUT (TYP ) <br />- - - - - <br />I <br />- - - - - <br />I <br />a <br />DI NIg <br />RO <br />El <br />I <br />I <br />14' S/A <br />FROM <br />1tU <br />A50VE <br />BEDROOM #2 <br />I\�------+---------- <br />--- 1 12X8 <br />-- <br />III� <br />12XI2 <br />- <br />—2 <br />iIi�II <br />01------------------- <br />III <br />TI—mHAR-5L8I <br />B—A—TH-5-0# <br />— <br />LMEITCHIN.L' <br />-• -,�II <br />Xt <br />I <br />STOR• <br />_______ <br />O` <br />12X8 8 EL <br />9Xs/ <br />FLEX <br />III FOYER <br />III <br />I <br />I <br />I PORCH <br />I <br />8' S/A <br />FROM <br />ABOVE <br />GARAGE <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE: 1/4 • I'-0' <br />1 N. RONALD REAGAN 81 <br />LONGWOOD, FL 32750 <br />PH: 407-774F078 <br />FAX: 407-7744078 <br />w .abdeslgngroup.00m <br />AA M: 0003325 <br />w <br />m <br />� <br />� <br />n <br />04 <br />s <br />a <br />BL77 mv. & I.OT: <br />ABBOTT <br />PARK <br />LOT #16 <br />BLK #9 <br />PROJECT* <br />04181.000-16091 <br />MODEL• <br />4EHB <br />"2605—HAYDEN" <br />C;ARACiE BIFMC;: <br />RIGHT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />60 JIPH M. <br />DAIM 06/14/21 <br />SCALE: 1/4"=V-0" <br />SHEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.