Contractor
D R Horton
Building Plans - Permit #
210
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BAGGER ROD <br />SACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE E)04ALI6T. <br />SEn ��—E OF FLASWMG TO BE. <br />1. BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO Be SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />AFL ALL SIDEE& Y1 CAULKING • JOINT <br />AROUND <br />PER SECTION R703.7 <br />E)derior letldno and plazie ft <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926.12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 106312A. <br />WPM LAYER -1, <br />STUCCO WRAP <br />1 .: <br />WOODED VENT <br />J' THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT ( (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER "2 (FORTIFIBER ------ <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-0% MIN. 2.5 LBS. <br />PER 60. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANI.P. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />(@ DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />I <br />6' SELF ADHESIVE—. <br />FLASHING (INSTALL <br />PER MANUF, SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALES N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />AAM=AA I V IfGtrG I V G <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC, <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED WOUSEWRAP <br />FOR SOX INSTALLATION <br />WRS LAYER P, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />WOUSEWRAP <br />BELOW <br />CUT SUCH THA' <br />NO MEMBRANE <br />ENTERS SOX, <br />APPLY TO FAA <br />EDGE <br />APPLY E-Z <br />OVER 6® MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />i <br />In P]ffI� <br />WOOD SWEATHMG <br />MRS LAYER -1, <br />STUCCO WRAP <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRJCTURAL <br />MEMBER • T' OC. MAk <br />T x' MID -WALL <br />•' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BB'OIeB APPLYING <br />— V FINISH • MASONRY <br />HORIZONTAL WEEP SCREED <br />{FRAME TO BLOCK) <br />UIRB LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />STEP 01 <br />STEP 02 <br />ti <br />UERIB LAYER <br />STUCCO WRAP <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOU89WRAP <br />STEP *3 <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />�- WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />STEP 1*4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP Oro <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD,FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeslgngroup.com <br />AA #. 0003325 J <br />�e <br />FG <br />IV. to LOT <br />OTT PARK <br />LOT 5 <br />LK 10 <br />CCT* <br />.000 05104 <br />L: <br />4EBB <br />28—CAU" <br />sIC BWMCI: <br />LEFT <br />PAGZ: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />DATZ 04/08 77 <br />SCALE: 1/4"=1'-O" <br />all== <br />WA2 <br />