Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(8) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEO.UENCE OF FLASHING TO BE, <br />I'_ X: <br />1. BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />i <br />WATER AWAY FROM JOINTS. <br />1X�I <br />E-Z BEAD ALL AROUND <br />' <br />VENT -APPLY SEALANT ALL <br />i <br />X <br />JOINTS AND INTERSECTIONS <br />' <br />I <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES. JW CAULKING a JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Extedor lathing and plastering <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply with the application <br />.X. <br />1 1 - <br />requirements of ASTM C 926-18b. <br />Installation of e)dedor lathing and framing <br />I T <br />shall comply with ASTM C 1063-19a, <br />Or ASTM 1787. <br />WRB LAYER •I, <br />STUCCO WRAP <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />il <br />PLASTER <br />METAL LATH <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />LAYER'1, <br />STUCCO WRAP <br />LAYER 4, FORTIP15ER <br />BUILDING PAPER <br />c�aTucnoN <br />�METAL LATH <br />a' CMU VINYL CASING DEAD <br />W RAISED BAND <br />$' TON Mln-,u L <br />nee amen <br />6' ODE STRIP SELF <br />ADHESIVE FLASHNG, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />WjSTONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER e2 (FORTIFIBER — — — — • — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR '7/Iro' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R'103.7.1 / ASTM C-84'1-14a, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />b' SELF ADHESIVE <br />WOOD CONSTRUCTION <br />OVER TOP 4 SIDES <br />SELF <br />WOOD SHEATHING <br />FLASHING <br />10e <br />WRB LAYER 01, <br />UNIT <br />STUCCO WRAP <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />RTIFIBER <br />�— <br />BUILDING PAPER <br />TOPLANT 4 SIDES I I I\/I _��. <br />THICK, 3 COAT CEMENT <br />6B DRYER VENT (BLOCK) \EEFED ALL <br />UX= <br />CONSTRUCTIGN <br />6' SELF-ADHESIVE <br />FLASHING a' CM � <br />BUILDING PAPER <br />OVER 'QUICK WOOD FRAMED <br />FLASH' F_ — — — —I WALL <br />_ HORIZONTAL WEEP SCREED <br />PIPE THROUGH / • <br />WALL % ( FRAME TO FRAME) <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />s+l�cf+ Iv Iccl..clrc <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />1 <br />I <br />APPLY STUCCO SCRATCH COAT <br />AND ONE lU LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />'7R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />A SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />WOOD SHEATHING <br />ALM LAYER M, <br />STUCCO WRAP <br />'UPS LAYER 4, FORTIF15ER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' O.C. MAX <br />K' TO %rI' MID•WALL <br />wEEP xREeD <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V FINISH • MASONRY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />S' <br />WRB LAYER sl, <br />GUT OPENING IN <br />STUCCO WRAP <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />77 <br />CUT 'X'INTO <br />WRB LAYER •I, <br />SELF -ADHERING <br />/\ <br />STUCCO WRAP <br />MEMBRANE FLASHING <br />LL9APPLY <br />SELF -ADHERING <br />WOOD SHEATHNG I <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER fl <br />STEP #1 <br />STEF <br />#2 <br />APPROVED <br />HOUSEWRAP <br />WRB LAYER'l, <br />BELOW <br />STUCCO WRAP <br />CUT SUCH THAT <br />APPLY 60 MIN <br />SELF -ADHERING <br />NO MEMBRANE <br />GRADE 'D' FELT <br />MEMBRANE FLASHING <br />ENTERS BOX, <br />7149 <br />_ <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIP15ER <br />BUILDING PAPER <br />STEP #3 <br />STEF <br />04 <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE '0' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEF #5 STEP #& <br />l 9) ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32760 <br />PH: 407-7746078 <br />FAX: 407.7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />rn <br />W <br />qms <br />1 <br />� <br />it <br />p� <br />pU <br />scrlaDly ae ' T: <br />ABBOTT PARK <br />LOT #30 <br />BLK #7 <br />PROJECT# <br />04181.000-30071 <br />MODEL. <br />E401 <br />"2828—ENSLEY" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH fV. C <br />PRINT 214 <br />DATE: 08 / / 1 <br />SCALE: 1/4"=1' - 0" <br />SHEET <br />WA.2 <br />