Laserfiche WebLink
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL BI CLAW I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, STALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS $HALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS, <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR 1 WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRAY, <br />l <br />BALANCING DAMPER OR OBD <br />t, <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN Y LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />® <br />PASS-THRJ AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O <br />O <br />__--EXTERIOR WALL <br />PLENUM <br />T <br />y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />SECURE STRAP TO CONC. <br />CONDENSER <br />W/ (2)-3/16'X2' TA <br />UNITr1l <br />SIMPSON WB ROLL STRAP <br />y <br />OR EQUAL <br />AIR HANDLER <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />SECURE STRAP TO UNIT W/ (2) <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />4' CONCRETE SLAB GSXI 1/4' $HT. MTL. SCREWS <br />T <br />REFRIGERANT LINER TO <br />CONDENSER UNIT <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />CONNECTION TO PAD <br />IN AN APROVED DRAIN, PER <br />FBCR 1TH EDITION (2020) <br />NOTE: MAIN COND. DRAIN 3/4' DIA. <br />MECHANICAL CODE <br />SECTION 301].4 <br />OVER HEAD • 12' FROM STRUCTURE <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR <br />BRONZE FL. PL. OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.VjC OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYPN <br />COWTERSUNK <br />C.O. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />1'-S'X8' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />I)EXT. GROUND CLEAN -OUT (TYPN ) <br />I <br />I <br />D�NN_G <br />j,IyIxG F OM KKVOVVD�1 <br />H�OM FROM <br />BEDROOM-" ABovE� <br />T <br />I2X8 <br />----- ---------- <br />II _— <br />z-------'� IT r <br />--------- 14X 12XI2 <br />PASS <br />BATH #2 THRU C <br />`+X I---- ------------------- + G <br />g0 <br />i X , <br />KITCHEN <br />WH O =_ PAN• <br />GARAGE <br />Am I <br />e' S/A j <br />FROM <br />ABOVE <br />ul , <br />III , <br />I I <br />FOYER i FLEX <br />III <br />III <br />PORCH <br />FIRST FLOOR MECHANICAL PLAN <br />SCALE: 1/4 . I'-0' <br />0 <br />JUN <br />• <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />W W W.abdeSIgngroup.com <br />116 AA #: 0003325 <br />SVHDIV. m LOT: <br />ABBOTT <br />PARK <br />LOT# 281BLK# 7 <br />PROJECT* <br />04181.000-28071 <br />MODEL.• <br />4EHB <br />"2605-HAYDEN" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />60 MPH <br />