Laserfiche WebLink
6' <br />FLANGAE6 OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO ME, <br />X: <br />L EOTTOM. 2. SIDES. 3. TOP <br />VENT CAP B TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 16 TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />x' <br />E-Z BE ALL AROUND <br />1 <br />;{r <br />VENT -APPLY SEALANT ALL <br />1 <br />JOINTS AND INTERSECTIONS <br />' <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, 4 CAULKING • JOINT <br />I <br />I <br />ALL AROUND <br />I I <br />PER SECTION R70&7 <br />EKbww kftw and alaalefkla <br />BACKER ROD <br />I I <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />1 <br />r' <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />WRB LAYER M, <br />': <br />or ASTM 1787. <br />STUCCO WRAP <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />RM LAYER °2, FORTPIBER <br />BUILOMG PAPER <br />WOOD SHEATHMG <br />DRYER VENT <br />(FRAME) <br />WOOD SMAT14MG <br />UM LAYER °I, <br />STUCCO UARAP <br />UNIS LAYER 4, FORTPIBER <br />—METAL LATH <br />6' Cm VINYL CAONG BEAD <br />6' RAISED BMA <br />x' TO 1i M!n_nw <br />IIIFEEP aCIRPED <br />PLASHING <br />STOW VENEER <br />OVER SCRATCH COAT <br />7 <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ...... <br />- - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR '1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-103.11 / ASTM C-841-14a, MIN, 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 1 SIDES <br />C B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH- / <br />ULALL `� <br />1 <br />V SELF ADHESIVE— <br />PLA6HMG (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPEI <br />UNDER 'QUICK FLA& <br />A VENT PENETRATION <br />SCALE: N TA. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />< 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />3 COAT CEMENT <br />K' TO Yd MID -WALL <br />WF_EP SCREED <br />�6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENMG IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER <br />STUCCO UJR< <br />WOOD SHEATHING <br />AF'PROVEp <br />HOUSEWRAP <br />BELOW <br />THAT <br />9 <br />EMBRANE _ <br />BOX, <br />FACE <br />EDGE <br />CUT SUCH <br />NO M <br />ENTERS <br />APPLY TO <br />WOOD SHEATHMG <br />LAYER °I, <br />STUCCO WRAP <br />LAYER 02, PORTIFIBER <br />SUILOMG PAPER <br />METAL LATH <br />WOOD T/ I'.D <br />CONBTItlJCTION an <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • 1. O.C. MAX <br />a' O'u <br />x' To Jr MA -WA L <br />u>EaP <br />E <br />61 ADFBE N6 R HW.% CLEAN <br />Sa MASONRY BEFORE APPLYING <br />V FINUH • MASONRY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />S' <br />WRB LAYER sl, <br />STUCCO WRAP <br />WRB LAYER 9, <br />STUCCO WRAP <br />APPLY 60 MM SELF -ADHERING <br />GRADE 'D' FELT MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />PLASHING OVER <br />APROVED <br />HIOUSEWRAP <br />�- u>RD LAYER 02, FORTIFIBER <br />SILDING PAPER <br />TEP <br />#3 STEP 04 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />APPLY E-Z BEAD <br />(SEE TYPICAL WALL <br />OVER 60 MIN <br />;.; <br />SECTION) <br />CsRADE '0' <br />;; <br />�° <br />`` <br />METAL LATH <br />FELT -PROVIDE <br />; <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />STEP *5 STEP #6 <br />n9 ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONG WOOD, FL 32780 <br />PH: 407-774.6078 <br />FAX: 407.774-4078 <br />www.abdesigngroup.com <br />AA M: 000.2. <br />y <br />o <br />i <br />F <br />TT PARK <br />T #27 <br />LK #7 <br />CT0M 27071 <br />a <br />4EAB <br />72-ARIA" <br />E 91rWG: <br />RIGHT <br />1PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH E C <br />