HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING, ALL SEAMS SHALL BE SEALED WITH GLASS FA15 4 MASTIC. AND <br />INSTALLED AS PER MC 6TH EDITION (2011) MECHANICAL 15LM CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NPPA WA 2-3.1 <br />4. FMO14 AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, 814ALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER PBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />T. BATHROOMS CONTAINING BATHTUBS, SHOWED, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH PBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9 ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND P5C 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED UITN BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH 05F BOOSTER PAN OR EQUAL. <br />PANTEC14 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR 050 <br />0 <br />CEILING EXHAUST PAN <br />CEILING EXHAUST PAN a LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />® <br />PASS-THRU AIR GRILL <br />FREE DRAW AIR <br />HANDLER CLOSET <br />W/LOUVERED DOOR <br />SUPPLIED BY <br />BUILDER <br />SECOND FLOOR <br />MECHANICAL PLAN <br />SCALE, 1/4 • P-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeaWgrouP.com <br />AA 0: 0003325 <br />S <br />gig <br />a <br />lei <br />11 <br />AoafrF� <br />PARK <br />LOT ##8 <br />BLK #10 <br />P1tojmcT# <br />04181.000-08103 <br />MODSI.c <br />3EFB <br />"2447— ROBIE" <br />GARAGIC SWING: <br />RIGHT <br />PAGE: <br />SECOND FLOOR <br />MECHANICAL <br />PLAN <br />60 MPH EXP. <br />