Laserfiche WebLink
• <br />(I OR 2)USP RT16A WHEN INSTALLING (1)USP <br />RT16A ON THE INSIDE <br />TRUSS ANCHOR WITH (1 OR 2) USP OR WITH <br />FASTEN EACH STUD TO DBL. <br />TRUSS <br />A HOG NAILS TO TRUSS ANCHOR WITH <br />TOP PLATE N USP SPT24 PLYWOOD SHEATHING, SEE PLYWOOD SHEATHING, SEE <br />TRUSS AND 10dx3" HDG NAIL PER MANUF. SPECS. "ROOFIWALUFLOOR t0dz1 tl2" GALV. COMMON "RCOFNVAILIFLOOR <br />NAILS TO NAILS, FILL ALL HOLES. <br />TOP PLATE. FIRST ONE SHEATHING FIRST ONE SHEATHING <br />FASTENER SCHEDULE" FASTENER SCHEDULE" <br />APPLIED TO INSIDE FACE APPLIED TO INSIDE FACE <br />OF WALL. IN ADDITION,7 OF WALL. IN ADDITION, <br />ADD (4)16d TOE -NAILS, 2 ADD (4)16d TOE -NAILS, 2 <br />EACH SIDE OF TRUSS. EACH SIDE OF TRUSS —� <br />2x WOOD FASCIA SEE <br />ARCHITECTURAL 2x6 <br />Nf_050:5: <br />SECURED W/ (2) t6d <br />GALV. COMMON NAILS. <br />ENGINEERED WOOD <br />1x2 SECURED WI 10d <br />TRUSSES 0 24" O/C, <br />GALV. COMMON NAILS <br />SUBMIT SHOP DRAWINGS <br />12" O/C <br />FOR REVIEW <br />AND APPROVAL <br />2x STUDS <br />2x BLOCKING <br />AT ALL PLYWOOD <br />A ALLOWABLE UPLIFT = 1160 LBS (1 STRAP) <br />SEAMS <br />B ALLOWABLE UPLIFT = 2320 LBS (2 STRAPS) <br />alb <br />TYPICAL TRUSS/GIRDER CONNECTOR S <br />SCALE: 3/4"=1'-0" <br />PRE-ENG GABLE TRUSS — <br />2x4 BLOCKING BETWEEN TRUSSES <br />AT FIRST TWO SAYS *4r O.C. (AT <br />SHEATHING SEAMS)(BLOCKING <br />NOT SHOWN FOR CLARITY) <br />2X4 DIAGONAL BTM. CHORD <br />BRACING. SEE PLAN FOR <br />LOCATION <br />SECURE 2m PLATE TO WALL <br />W/ 318'W' THRU-BOLTS 0 <br />32" O.C. MAX THEN SECURE <br />GABLE PLATE W/ <br />12d's 8" O.C. MAX OR <br />SECURE GABLE <br />TO TO DBL TOP <br />PLATE W/ USP HGA10KT <br />® 24" O.C. MAX <br />I2x STUDS <br />2x WOOD FASCIA SEE <br />ARCHITECTURAL 2x6 <br />SECURED W/ (2) i6d Ile <br />PRE-EN <br />TRUSS (TYP) @ 24" O.0 <br />A MAX <br />FOR STRAPPING <br />VERIFY <br />W/ TRUSS PLAN <br />2x STUDS <br />CONT. 2X4 SECURED W/ (2) 10d's ® EACH <br />TRUSS TO BE INSTALLED 0! 10'4" O.C. MAX. <br />GABLE END BRACING W/ PRE-ENG <br />GABLE TRUSS @ FRAME WALL <br />5 SCALE: 3/4"=1'-0" <br />PLYWOOD <br />GALV. COMMON NAILS. <br />ENGINEERED WOOD <br />1x2 SECURED WI 10d <br />TRUSSES � 24" OIC, <br />GALV, COMMON NAILS <br />SUBMIT SHOP DRAWINGS <br />12" O/C <br />FOR REVIEW <br />AND APPROVAL <br />2x STUDS <br />AT ALL <br />ROOF TRUSS UPLIFT <br />CONNECTOR NOT SHOWN <br />FOR CLARITY (SEE SHOP <br />OWGS.) <br />FASTEN EACH STUD TO <br />DBL. TOP PLATE W/ USP <br />SPT24 NAIL PER MANUF. <br />SPECS. <br />TOP PLATE ROLLOVER <br />3 STRAP DETAIL <br />SCALE: 3/4"=1'-0' <br />4 NOT USED <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32780 <br />PH: 407-774.6078 <br />FAX: 401-7744078 <br />wwwAbdoeigngroup.com <br />AA #: 0003326 <br />5 <br />O <br />s Aoalr I <br />PARK <br />LOT #8 <br />BLK #10 <br />PROJECT# <br />04181.000-08103 <br />MODEU <br />3EFB <br />"2447- ROBIE" <br />GARAGE 8VM4Q- <br />RIGHT <br />PAGE: <br />DETAILS <br />60 MPH EXP. <br />