My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7807 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7807 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:47:36 AM
Creation date
2/24/2025 9:29:15 AM
Metadata
Fields
Template:
Building Plans
Street #
7807
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
2653
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER STUCCO <br />TOP, SIDES) AND BOTTOM FINISH <br />FLA14ES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. 6' SELF ADHESIVE WOOD CONSTRUCTION <br />BEOUENCE aF FLASHING TO BE, OVER TOP a SIDES <br />I. BOTTOM. 2. SIDES, 3. TOP <br />XII : VENT CAP IS TO BE SET IN BED SELF{ WOOD SHEATHING <br />M SIDES ONLY. SEALANOF SEALANT AT TOP TIIB To BE FmL�ASHING ' WRB LAYER "IUIT, <br />I TOOLED SO AS TO DEFLECT STUCCO WRAP <br />WATER AWAY FROM JOINTS.1441 N. RONALD REAGAN BLVD. <br />x E-Z BEAD ALL AROUND <br />PREMANUF. DRYER LONGWOOD, FL 32750 <br />VENT -APPLY SEALANT ALL VENT CAP (SET IN WR5 LAYER "2, FORTIFIBER FAX: 407774.4078 <br />is JOINTS AND INTERSECTIONS CONT. SEALANT) IBUILDING PAPER www.abdeslgngroup.com <br />APPLY SEALANT AT PERIMETER OF BACKER ROD NON -MOVABLE FRAME AND STUCCO AA#:0003326 <br />' <br />ON ALL BIDES. Y4 CAULKING ,JOINT <br />ALL AROUND <br />SEALANT a <br />TOP < SIDES <br />THICK, 3 COAT CEMENT <br />WOOD SHEATHING <br />PER SECTION R 03.7 <br />PLASTER <br />LAYER -1, <br />I Exteft lathing and plRssterino <br />STUCCO WRAP <br />BACKER ROD Exterior use of Portland cement plaster <br />shall comply with the application <br />6 B DRYER VENT (BLOCK) <br />T <br />LAYER Q, FORTIFIBER <br />_ BUILDfNG PAPER <br />- requirements of ASTM C 926-18b. <br />X: <br />la' SCREED <br />METAL LATH <br />METAL <br />X: Installation of exterior lathing and framing <br />WooDRIrMle uJ00DD <br />CONSTCTION <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />6' SELF-ADHESIVE <br />FASTEN TO WOOD STMACTURAL <br />WRB LAYER -1, <br />FLASHING <br />a, U MEMBER T' O.G MAX <br />STUCCO WRAP :: HOODED VENT <br />BUILDING PAPER <br />WOOD FRAMED <br />W roK MID -WALL <br />THICK, 3 COAT CEMENT <br />ovER'QUI_ _ _ <br />FLASH' I- —1 <br />WALL <br />1 C6_O f4`OC6_ <br />PLASTER <br />METAL LATH <br />— <br />HORIZONTAL <br />WEEP SCREED <br />( FRAME TO FRAME) <br />WRS LAYER a, FORTIFIBER <br />PIPE THRWCsH�\� <br />WALL <br />.' WIDE STRIP SELF <br />BUILDING PAPER <br />'\ <br />_n,. ADHESIVE FLASFIW-s, CLEAN <br />WOOD SHEATHWG <br />MASONRY BEFORE APPLYING <br />\ <br />. � r.—.\ <br />TEXTURED <br />0 , <br />WOOD SHEATHING <br />MEMBRANE FLASHING <br />I <br />I <br />OVER BOX AND OVER <br />W 1WDE STRIP SELF <br />APPROVED WR5 <br />ADHESIVE PLASHING, CLEAN <br />LAYER fl <br />MASONRY BEFOREAPPLYING <br />STEP #1 <br />STEP <br />#2 <br />Z FLASHING <br />ELEC. METER FIELD <br />I <br />VERIFY LOCATION <br />ELEC. METER FIELD <br />NouWR�AP <br />STONE VENEER <br />OVER acRATCFI COAT <br />VERIFY LOCATION <br />BELOW <br />WR5 LAYER h, <br />STUCCO WRAP <br />HORIZONTAL WEEP SCREED <br />• <br />APPLY STUCCO SCRATCH GOAT <br />AND ONE (I) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />9 <br />- <br />to <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />STONE VENEER <br />METER <br />APPLY TO <br />SELF-AERING <br />(FRAME TO BLOCKZ <br />EDGE <br />EDGE <br />FLASHING OVER <br />FLASHING OVER <br />CAVITY TO 5E FILLED <br />WITH RIGID POLYMERIC <br />J <br />APROVED <br />HOUSEWRAP <br />ISOCYANOTE-POLY5LEND FOAM <br />WRB LAYER 12, FORTIP15ER <br />LEGEND <br />('GREAT STUFF' OR SIMILAR) <br />BUILDING PAPER <br />STEP #3 <br />&TEF <br />#4 <br />DRAINAGE PLANE (WR5 <br />BASE SEALANT�A�T POINT <br />LAYER •1 STUCCO WRAP) <br />THAT ELEC WIRE PENETRATES <br />e <br />aUSDIV & LOT <br />ABBOTT PARK <br />LOT #26 <br />BLK. #7 <br />PROJECT# <br />04181.000-26071 <br />MODEIA <br />4EBB <br />"1828—CALI" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%160 APH ER. C <br />WR5 LAYER 02 (FORTIFI5ER - - - - - COASTOMTINGG OVER <br />BUILDING PAPER) AREA TO RECEIVE STUCCO/C.V,FINISH <br />STUCCO SCRATCH GOAT APPLY E-Z BEAD • ••e.o.o gSEE)IGAL WALL <br />METAL LATH x—x—x—x a I COAT OF PAINT U1/BACK- OVER em MIN <br />ROLL PRIOR TO GRADE <br />' E METAL LATH <br />STUCCO ELEC. METER INSTALLATION PROVIDE STUCCO SCRATCH SEALANT AT ALL <br />WOOD OR/Ifo" ZIP WALL COAT LARGER THAN THE ELEC. JOINTS AND .I <br />METER CAN OR METER CAN INTERSECTIONS <br />SHEATHING ® COM50 OR METER CAN AND LF �j <br />23 <br />SELF-ADHESIVE FLASHING - - - - - DISCONNECT 11O°07 <br />NOTE: DA 6/14/91 <br />METAL LATH: LATH TO 5E PER SECTION OQ ELECTRICAL CONDUIT STEP #5 STEP #(o 91CAIX:1/4"=1'-0" <br />R103.1.1 / ASTM C-541-14a, MIN. 2.5 L55. U PENETRATION <br />PER SQ. YARD (UTILITY OR NOMINAL SHEET <br />DOES NOT MEET SPECIFICATIONS) ELECTRICAL RECEPTACLE WA2 <br />