DocuSign Envelope ID: 30814DOC-5684-4E90-9485-603907D32158 <br />EXISTING EXTERIOR CMU <br />I <br />MIN. 3" EDGE DISTANCE <br />I <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO - A <br />EXISTING FOUNDATION FACE w/ p P - — — o <br />— — <br />(2) ROWS OF 316" DIA. TAPCONS D / D a D <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. t <br />D - EXISTING FOUNDATION. <br />C <br />AI D D <br />I D \ <br />I \ ° <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL . I <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />I <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/g' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D <br />D ° <br />t D <br />ID D EXISTING FOUNDATION <br />p I \D pD <br />I I \ <br />D \ e <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />_ --0'-O" A.F.F. SEE ARCH <br />(MAX 20" <br />° //\\ 4 ° --- - DEEP) <br />/ <br />r\�\/\ <br />a 4 4 <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />6 BEARING CURB STEP SECTION <br />16" <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />xx <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />i A n xc nn•sriKii le-% BAR AS <br />VQ <br />_AP AS SHOWN <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />) DEGREE <br />TYPICAL STEP IN FOOTING DETAIL, <br />8" CMU CHAIR BLOCK W/ (1) #5 <br />CONTINUOUS TO EXTEND MIN <br />INTO MONOLITHIC THICKENED <br />� o <br />oU) <br />UZ <br />I — <br />STEMWALL,/-&MONO LITHIC <br />MIN 24" LAP <br />— _ _ - <br />— —<_ _ ,� •_ <br />—4- <br /><a . <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />#4 OR #5 <br />REINFORCING PER <br />° <br />MONOLITHIC FOOTING <br />SECTION <br />n n• 4 <br />a° 4 ` • <br />FOOTING TO BEAR ON FIRM <br />. 4, . , ; <br />— -- — —- a <br />UNDISTURBED SOIL <br />n..._ <br />< ___ < 4 4' <br />" MINI 12"\\\\\\\\\\ <br />• <br />//\//\�/\�/\�/\�/\�/\�//\r/\�/\�/ ' <br />`— • STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />•ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />LOCATE I E R TIP, <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT IN LAST <br />REINFORCEMENT <br />STEMWALL CELL <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF.SLA� BLOCK W/ (1) #4 OR #5 CONT. <br />co <br />------- U) <br />¢ Q o <br />VAPOR BARRIER \\L o X <br />#4 OR #5 VERT REINFORCING <br />UP TO 3 COURSES: 72" O.C.\//\\/ <br />4 TO 5 COURSES: 48" O.C. <br />\\\�� ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM //� / #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />C <br />STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. <br />(BEYOND) - - <br />FLOATING CONCRETE w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 w U (1) #4 OR #5 <br />WWF OR FIBERMESH > Q Q CONT <br />•'• wW <br />UJ <br />�. <br />- A- U Of FINISH <br />j\� O GRADE <br />\/% <br />#4 OR #5 VERT REINFORCING //� //� <br />UP TO 3 COURSES: 72" O.C. j I \ \\L\\/ <br />4 TO 5 COURSES: 48' O.C. <br />FOOTING TO BEAR ON FIRM ADDITIONAL #4 OR <br />UNDISTURBED SOIL <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO <br />HAVE 6" BEND @ BOTTOM N OPT BRICK LEDGE <br />NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />(1) 44 OR #5 CONT. <br />3VARIES PER <br />6" MAX <br />ARCH PLANS <br />\r <br />12" MIN <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />3'/z' CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />�2/—(1) <br />MINIM <br />#4 OR #5 90' BEND @ 48" O.C. <br />VAPOR BARRIER <br />/ <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />..\ ; <br />b <br />12" UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE - <br />16" UNDER 2 STORY WALL W/ (3) <br />[#4 OR (2) #5 CONT - <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE`: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1 A WWF OR <br />FIBERMESH <br />- — --------- <br />SEE NOTES (MAX 16") U <br />0 <br />STUCCO OR DIRECTLY ADHERED M <br />STONE CLADDING FINISH - MIN 6" CD16 <br />ALL OTHER EXTERIOR WALL N O <br />�OW \ <br />/\\��i �\ \ <br />o n D CLADDING -MIN 8", U.N.O. ON ARCH O VAPOR BARRIER APEX �O <br />12"MINX U <br />O <br />FOOTING TO BEAR ON ' <br />FIRM UNDISTURBED 6" OPT. EXTENSION IN BRICK �- <br />SOIL LOCATIONS ON FND PLAN N <br />12" UNDER 1 STORY WALL w/ cc i <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 J <br />BAR IN BRICK LEDGE U_ <br />16" UNDER 2 STORY WALL w/ Cl <br />(2) #5 OR (3) #4 CONTINUOUS J <br />true design studios <br />1 MONOLITHIC FOOTINGSECTION- z <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O <br />FOLLOWING OCCUR: Y :;:3 <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U 9000 REGENCY SQUARE BLVD. C <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY Q SUITE 100, JACKSONVILLE, FL 32211 <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY 0 <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. 0 <br />O <br />CONCRETE SLAB w/ 6x6 cn <br />(2) #4 OR (2) #5 CONTINUOUS w cy <br />W1.4 x W1.4 WWF OR <br />FIBERMESH ~ g <br />041HO90N (1)- U) <br />° a d Z3 <br />\�\\ 4 ° m <br />Lij <br />/ 16" VAPOR BARRIER Q <br />Z <br />W <br />3 BEARING WALL FOOTING SECTION Z a) <br />w <br />(D <br />w <br />CONCRETE SLAB W/ 6x6 w <br />O W1.4 x W1.4 WWF OR <br />FIBERMESH O <br />0'-0" A.F.F. <br />SEE ARCH <br />°- DETAILS r' e <br />`-a� - LO <br />8" MIN C• V J 4 <br />z W <br />8"x8" THICKENED 8" cn <br />FTG AT U) <br />LLI <br />STEP-DOWN, SEE VAPOR BARRIER <br />PLAN <br />4 CURB STEP SECTION m LU O Cn <br />w <br />�_- W <br />w Q O <br />8" UNDER MASONRY WALL Z_ <br />6" UNDER WOOD WALL > Q Q <br />CONCRETE SLAB W/ I z <br />6x6 W1.4 x W1.4 WWF w 0 <br />- w <br />OR FIBERMESH VARIES ° SEE ARCH Q <br />--- - <br />(MAX 16") LLI ti <br />_ <br />�//7/C�%\ � x\\ \\ \\ \ LL r- <br />° / 12" MIN./\/\/\/\/\� <br />Z <br />VAPOR BARRIER //\ ° 4 �/\ j\/i�//�//�// Z <br />O <br />r r <br />6 OPT. EXTENSION IN BRICK O �- <br />LOCATIONS ON FND PLAN d Z <br />12" UNDER 1 STORY WALL w/ <br />a <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO.4 OR NO. 5 0 L. <br />BAR IN BRICK LEDGE — <br />16" UNDER 2 STORY WALL w/ `0 w <br />(2) #5 OR (3) #4 CONTINUOUS ABBOTT PARK Q <br />GARAGE EXT WALL CURB_SECTION <br />C-)F CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE LOT 025-01OLLOWING OCCUR: I-_ <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" U <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY z Z z <br />FROM STRUCTURE STEEPER THAN 1'-O" VERTICALLY _ <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. U) <br />PROJECT NO. w <br />CONCRETE SLAB W/ 6x6 O 2021.006624 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH Z oruawN - -- O <br />0'-0" A.F.F. _ SEE ARCH v KME o <br />(MAX 20" LU <br />_ <br />°_ a DEEP) CHKD: MJP U) <br />4"w LU <br />° 4 ii <br />4" EXTENSION <br />UNDER BRICK VENEER `��`S��N LqN� ��i,� W <br />12" UNDER STORY WALL } �� ��.•' <br />0 <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m � C E N `S' 9 ��+ Z <br />No 85166 �S <br />16" UNDER 2 STORY WALL LU z* •:• <br />W/ (3) #4 OR (2) #5 CONT ' Do*uSign•d by: <br />Q <br />BEARING CURB STEP SECTION O %�� CTxf'E"" OF i <br />C6) O ••, 3F4671DACDEF446..:(/ <br />'�` C� <br />z ,�'�� S�Q N AL E'C.ol 'S <br />TYPICAL REINFORCING <br />BARS AT FTHICKENED FOOTING, SEE <br />I I I <br />MIN 24" LONG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />I II <br />L <br />I---————————- <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />U) <br />O_ 05-18-2021 0 <br />w <br />U_ REVISIONS: <br />U_ - IL <br />Q No. Description -Date w <br />J <br />O <br />—I - — O <br />Z Z <br />= O <br />U � <br />w <br />I— <br />x <br />W T=2mD <br />Q <br />CMU/METAL CONNECTOR ENGINEERING <br />