My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7832 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7832 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 7:06:59 AM
Creation date
2/24/2025 10:14:40 AM
Metadata
Fields
Template:
Building Plans
Street #
7832
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2426
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
II 11" 1 1 ' 1-1 l It, I ' " -- IL I'-. - I <br />)ocuSign Envelope ID: 30814DOC-5684-4E90-9485-603907D32158 <br />r_ <br />O 0 <br />O U <br />CV <br />L0 <br />�- 0 <br />4 APEX d 0 <br />O <br />O � <br />X <br />tV <br />CV <br />M <br />J <br />ILL AOOOO <br />LL <br />J � <br />J <br />Z t S <br />O true design studios <br />Y <br />U <br />9000 REGENCY SQUARE BLVD. <br />c SUITE 100, JACKSONVILLE, FL 32211 c <br />O vi <br />0 <br />W <br />� N <br />j) CA a. <br />UOH090N' <br />/ \ ELECTRIC METER w <br />\ ELECTRIC METER 1 f - FIELD VERIFY LOCATION <br />FIELD VERIFY <br />LOCATION APPLY STUCCO SCRATCH COAT AND ONE (1) <br />PRE -FORMED CONTROL ' 5/8" CEMENT PLASTER - LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC Cy <br />JOINT W/ STRIP LATH • ' <br />12" WIDE SELF-ADHESIVE METER (q <br />FLASHING CENTERED UNDER <br />_-+ a ��:.- `� • ' CONTROL JOINT (CLEAN CAVITY TO BE FILLED U <br />,. <br />�' '--- MASONRY BEFORE APPLYING) - WITH <br />RIGID <br />POLYMERIC <br />W 0 <br />FOAM ("GREAT STUFF" OR W <br />/ - .--- SIMILAR) � <br />. / APPLY A SILICON BASE 0 <br />STUCCO FINISH SEALANT AT POINT THAT O <br />- - ELEC WIRE PENETRATES � <br />5/8" CEMENT PLASTER / <br />/ 6" SELF ADHESIVE � <br />12" WIDE SELF-ADHESIVE L ` OVER TOP & SIDES I� <br />FLASHING CENTERED UNDER <br />CONTROL JOINT (CLEAN \ SELF FLASHING • O <br />MASONRY BEFORE APPLYING) / Z <br />UNIT <br />- --- - PROVIDE STUCCO w <br />PRE -FORMED CONTROL . -- - " SCRATCH COAT LARGER w `� <br />JOINT W/ STRIP LATH T �--_ { THAN THE ELECTRIC Z <br />•j / PREMANUF. METER CAN OR METER Uj <br />DRYER VENT CAP Z) <br />.1 _ f / (SET IN CONT. CAN COMBO CO METER <br />8" CMU � {�.,. SEALANT) AREA TO RECEIVE CAN AND DISCONNECT m <br />r. SEALANT at STUCCO SCRATCH COAT W <br />& 1 COAT OF PAINT W/ W <br />TOP & SIDES BACK -ROLL PRIOR TO W <br />_ ELECTRIC METER Z <br />INSTALLATION Z <br />w O <br />Q <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION o <br />SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. U- w <br />Wy <br />O L.t_ <br />I. L Q <br />a <br />- WOOD CONST BEYOND W <br />FIBERCEMENT -OR- VINYL LAP a <br />WOOD SHEATHING SIDING OVER APPROVED I <br />6" SELF -ADHERING WEATHER RESISTIVE, HOUSEWRAP INSTALLED PER O <br />FLASHING BARRIER #1 FINISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS U X <br />THREE COAT STUCCO FINISH EXTEND HOUSEWRAP d r' <br />WEATHER RESISTIVE WEATHER RESISTIVE (7//8" NOM) OVER GALV MTL LATH <br />BARRIER #1 BARRIER #2 WD SHEATHING f OVER 15# FELT OVER APPROVED OVER NAILING FLANGE Z <br />d \ \ (RE: STRUCT) !', HOUSEWRAP WD SHEATHING O O <br />VINYL ANGLED Q\ <br />CASING BEAD WEATHER RESISTIVE x: (RE: STRUCT) J p <br />(AM66-ANGLED-1250) BARRIER #2 \ 5/16" X 7 1/4" LAP FASTEN TO WD STRUCTURAL _ U_ LL1 <br />'IT\ SIDING W/ 6 REVEAL' MEMBER at 7" O.C. MAX _ MTL DRIP FLASHING W/ Q ~ <br />_ _ STARTER STRIP ' " TO � "MID -WALL - HEMMED EDGE SET IN CONT - z <br />2 1/2 A,�r? <br />, WEEP SCREED _ BEAD OF SEALANT Z - a <br />HCM CORNER BEAD - / DO NOT CAULK OR TRIM (RE: ELEVATION) - LL <br />(FASTENER & 6" SELF ADHERING SEAL OPENING _ _ z_ CL - <br />�, y^ SPACING at 7"O.C.) FLASHING / `„ < - -- <br />zz o _ MEMBRANE FLASHING OVER <br />(� W <br />m a N GALV'D METAL <br />�— GALV'D METAL "T' - WINDOW FLANGE SET IN CONT J <br />- } ~ '7' FLASHING a 6" WIDE STRIP SELF ADHESIVE O <br />(A U_ x - - cv - FLASHING BEAD OF SEALANT <br />W L w -_ :. FLASHING, CLEAN MASONRY <br />Z <br />> x DO NOT CAULK OR / 1 1/4" X 6" SIMULATED BEFORE APPLYING VINYL FLANGE CASING BEAD = PROJECT NO: W <br />Q SEAL OPENING - - WOOD TRIM MEMBER -- -- - INSTALLED PER MFR U <br />�' 1/2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) W Q <br />CMU 1 1/4" X 6" SIMULATED STUCCO i TEXTURED PER COMMUNITY _ _ --_ <br />r ~ Z <br />CASING BEAD SPECIFCATIONS 112" (MIN) STUCCO FINISH X DRAWN: <br />VINYL CASING - WOOD TRIM MEMBER .' :..' : TEXTURED PER COMMUNITY W DVO O <br />BEAD (AM66-1250) ---- <br />- 1/2" (MIN) STUCCO FINISH SPECIFCATIONS 12- <br />BEAD <br />1/2" (MIN) TEXTURED SPEC TEXTRED PER <br />COMMUNITY SEAL GAP W/ CAULKING CHKD TSD <br />FINISH at MASONRY OR APPROVED SEALANT STUCCO CASING BEAD ST v vO SIDING o <br />m 0 <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) - <br />SCALE: SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. z J <br />SCALE: N.T.S. O Q <br />W U <br />aC c� <br />Z 0 <br />Z <br />O <br />CMU WALL W/ SELF ADHESIVE <br />-OR- FLUID (CLEAN CMU WALL W/ ~ <br />1/2" MIN STUCCO APPLIED PAN LAS I G (C CMU LINTEL 1/2" (MIN) STUCCO FINISH ~ <br />(MIN) §8' STUCCO FINISH ( U <br />FINISH TEXTURED (RE: STRUCTURAL) MASONRY BEFORE APPLYING) (RE: STRUCTURAL) (RE: STRUCTURAL) <br />PER COMMUNITY __ I GYP BIRD OVER EXTEND UP AT JAMBS (4" MIN) " GYP BIRD OVER " GYP BIRD OVER Ur <br />SPECIFCATIONS" GYP BRD OVER PRE -SHAPED STUCCO BAND x2 TREATED I PRE -SHAPED STUCCO BAND 1x2 TREATED 1x2 TREATED Q Z <br />1x2 TREATED W/ SLIP TOP INSTALLED PER W/ INSTALLED PER MFR FURRING STRIPS FURRING STRIPS (A <br />FURRING STRIPS MFR WRITTEN SPECS (RE: FURRING STRIPS WRITTEN SPECS (RE: ELEV) <br />at CMU WALL (TYP) ELEV) at CMU WALL (TYP) PRECAST CONCRETE SILL at CMU WALL (TYP) CONTINUOUS BEAD at CMU WALL (TYP) CONTINUOUS BEAD <br />y ..... <br />FLANGE CASING OF SEALANT OF SEALANT > REVISIONS: <br />BEAD SELF ADHESIVE -OR- FLUID WOOD BLOCKIN SELF ADHESIVE -OR- FLUID fie" BACKER ROD W/ SEALANT PT 1x4 PT 1x4 C� - - <br />APPLIED FLASHING (CLEAN APPLIED FLASHING (CLEAN SELF ADHESIVE -OR- SELF ADHESIVE -OR- O NO. Description Date o <br />MASONRY BEFORE APPLYING) MASONRY BEFORE APPLYING) VINYL FLANGE CASING BEAD FLUID APPLIED PT 2x4 FRAME FLUID APPLIED -� -- W <br />PT 1x WOOD BUCK ti " GYP BRD OVER INSTALLED PER MFR PT 2x4 FRAME ANCHOR FLASHING (CLEAN ANCHOR FLASHING (CLEAN O (n <br />PT 1x WOOD BUCK VINYL FLANGE CASING BEAD VINYL FLANGE CASING BEAD — -- <br />_ _ SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR 1x2 TREATED WRITTEN SPECS (TYP) SHIM AS NEEDED MASONRY BEFORE MASONRY BEFORE Z W <br />gpp�Y NG� SHIM AS NEEDED qq��PP��YY NG� _ <br />FURRING STRIPS CMU STEMWALL W/ METALI DOOR FRAME METALI DOOR FRAME U -- <br />&Wee <br />-� WRITTEN SPECS (TYP) WRITTEN SPECS (TYP) at CMU WALL (TYP) �8" STUCCO FINISH W W <br />BACKER ROD W/ SEALANT 48' BACKER ROD W/ SEALANT (RE: STRUCTURAL) INTERIOR EXTERIOR INTERIOR EXTERIOR X - - - <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR <br />W U <br />CASING BEAD at WN WINDOW HEAD at <br />CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CMU o <br />SCALE: N.T.S. SCALE: 1 ti2" = 1'-0" SCALE: 1 ti2" = 1'-0" SCALE: 1 ti2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 11/2" = 1'-0" ZA501 O <br />5w <br />
The URL can be used to link to this page
Your browser does not support the video tag.