Search
7846 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7846 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 8:11:00 AM
Creation date
2/24/2025 10:09:40 AM
Metadata
Fields
Template:
Building Plans
Street #
7846
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
22252
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />INSTALL V SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, &IDE(S) AND BOTTOM <br />FLANGESOF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEAUM" OF FLASHING TO BE, <br />L BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET N BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 18 TO BE <br />TOOLED 80 AS TO DEFLECT <br />WATER AWAY FROM JOINT&, <br />E-Z BEAD ALL AROWD <br />VENT -APPLY SEALANT ALL <br />JOINTS AND NTERBECTIAO <br />APPLY SEALANT AT PERIMETER OF. <br />NON -MOVABLE FRAME AND STUCCO <br />OONLL ID &,Yi CAULKING • JONT <br />PER SECTION R708.7 <br />E)ti WINno and photBrinp <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 92612A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1083-12A. <br />WRB LAYER h, <br />STUCCO WRAP <br />HOODED VENT <br />THICK S COAT CEMENT <br />I. <br />PLASTER <br />METAL LATH <br />WRS LAYER Q, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />© DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH X—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.11 / ASTM C-841-0% MIN. 2.5 LBS, <br />PER SO, YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CANT. SEALANT) <br />SEALANT o <br />TOP 4 SIDES <br />F) B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />ELEC. METEI <br />VERIFY LO <br />PIPE THROUGH <br />WALL <br />1 <br />6' SELF ADHESIVE— <br />FLASHNG (INSTALL <br />PER MANUF. SPECW <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A <br />VENTPENETRATION <br />SCALE, N.TS. <br />I <br />I <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />STUCCO SCRATCH COAT <br />t 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENII�a IN <br />APPROVED HOLISEWRAP <br />FOR BOX INSTALLATION <br />AY WRH LAYER 01 <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTER BOX, <br />APPLY TO FA( <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT -PROM( <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />STEP #1 <br />STEP #3 <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />URB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />•1/8' TEXTURED <br />FINISH - WOOD <br />-FASTEN TO WOOD STRUCTURAL <br />MEMBER - 1' O•C. MAX <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYM <br />V FHOH1 - MAOON IRT <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />8' <br />WRB LAYER 01, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRS LAYER <br />FI <br />STEP <br />#2 <br />WRB LAYER N, <br />STUCCO WRAP <br />APPLY A MIN <br />SELF -ADHERING <br />GRADE 'D' FELT <br />® <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOIJKWRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP <br />#4 <br />id <br />ELASTCMMERIC <br />COATING OVER <br />STUCCO/ C V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP #6 <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN <br />BLVD. <br />LONGWOOD, FL 3278 <br />PH: 407-774.OD78 <br />FAX: 407-774.4078omwwwabdealgn�oup.AA #: 0003325 <br />b <br />J <br />4 <br />two <br />sumiliv. a <br />ABBOTT PARK <br />LOT #24 <br />BLK. #8 <br />PROJWTIP <br />04181.000-24081 <br />it[ODiEIs <br />3EAB <br />1504— ALLEX" <br />OARAGIC 87111W0: <br />RIGHT <br />PAG& <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />7:1 ; <br />- <br />IS <br />a9/12/10 <br />1/4"=1'-0" <br />A2 <br />