Laserfiche WebLink
INSTALL b' SELF-ADHERMKs <br />MEMBRANE FLASHING OVER <br />TOP, Slows) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO ISE, <br />L BOTTOM, 2. SIDES, 3. TOP <br />VENT CAP 18 TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />BIDES ONLY. SEALANT 18 TO BE <br />TOOLED 60 AS TO DEFLECT <br />i <br />WATER AWAY PROM JOINTS. <br />. X.n <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />� <br />.�. <br />APPLY <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />FRAME AND STUCCO <br />ON ALL BIDES, Y1 CAULKING a JOINT <br />ALL AROUND <br />I <br />PER SECTION R7 3.7 <br />Exterior lethina end gl8etertng <br />BACKER ROD <br />Exterior use of portland cement plaster <br />shall comply With the application <br />requirements of ASTM C 926-18b. <br />X. <br />IK: <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />' <br />r <br />_ <br />or ASTM 1787. <br />UIRD LAYER 01, <br />STUCCO WRAP <br />..: <br />t: <br />HOODED VENT <br />1' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER 12, FORTIFIBER <br />BUILDWG PAPER <br />WOOD SHEATHING <br />DRYER VENT <br />(FRAME) <br />r <br />SHEATHINGAYER'I,O WRAPAYER 4IFIBER <br />ING PAPER <br />oN�aTucnoN <br />-METAL LATH <br />a' Cm VINYL CASING BEAD <br />4' RAISED BAND <br />V TON <br />V WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MA60NRY BEFORE APPLYING <br />Z I-LASHNG <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />WISTONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ------ <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 7/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-14a, MIN. 2.5 L55. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP t SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />GB DRYER VENT(BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPEI <br />UNDER 'QUICK FLASI <br />A VENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METE1 <br />VERIFY LO <br />ii1CGN I V ICC6.GI VG <br />STUCCO SCRATCH COAT <br />t 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />`ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />J' THICK, 3 COAT CEMENT <br />PLASTER <br />TO K' MID -WALL <br />WEEP SCREED <br />WOOD <br />CONSTRICTION <br />6' SELF-ADHESIVE <br />FLASHING a• CM —� <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />A� —1-1 ')R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />'O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER el, <br />STUCCO WRAP <br />WOOD SHEATHING <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />Wit LAYER h, <br />STUCCO WRAP <br />Wit LAYER n, FORTIF15ER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRICTURAL <br />MEMBER • 1' O.C. MAX <br />%•sue wri�lin� L <br />ADHESIVE FLASHING. CLEAN <br />MA60NRY OEFORE APPLYING <br />(�oHORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />STEP *l <br />STEP #3 <br />S' <br />WRB LAYER "I, <br />STUCCO WRAP <br />WRB LAYER M, <br />STUCCO WRAP <br />APPLY 60 MIN <br />SEHE <br />9 <br />GRADE '' FELT <br />MEMBRANE FLASHING <br />® <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 4, FORTIF15ER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FNISH <br />(BEE TYPICAL WALL <br />SECTION) <br />METAL LATH �pv <br />u"�1 <br />STEP '5 STEP #& <br />l 9 ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-774-4078 <br />www.abdesigngroup.com <br />AA M: 0003326 <br />q <br />N <br />is <br />A <br />al <br />Miss <br />SEEN <br />ABBOTT PARK <br />LOT #22 <br />BLK. #7 <br />PROJECT# <br />04181.000-22071 <br />MODZU <br />4EHB <br />"2605—HAYDEN" <br />GARAGE a9wsrrG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH E C <br />DA=: 5/04/21 <br />awTE: <br />Eli 1/4"=V-0" <br />81MET <br />dd A2 <br />