Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />FEI"IBZANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />L BOTTOM. 2. SIDES, 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />. <br />,.� . <br />OF SEALANT AT TOP AND <br />;'. <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />i <br />JOINTS AND INTERSECTIONS <br />I _ <br />APPLY SEALANT AT PERIMETER Or - <br />BACKER <br />BACKER ROD <br />FRAME AND STUCCO <br />ON ALL SIDE& V CAULKING 0 JOINT <br />I <br />ALL AROUND <br />1 <br />PER SECTION R7 3.7 <br />Exterior latI IA and DIes01r4Ug <br />BACKER ROD <br />I <br />Exterior use of portland cement plaster <br />shall comply with the application <br />.x <br />requirements of ASTM C 926-18b. <br />.k <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />� <br />,: X - <br />or ASTM 1178T <br />WRB LAYER -1, <br />.'� <br />JC: <br />STUCCO WRAP <br />rl <br />;I <br />:; - <br />HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER rl, FORTIFIBER <br />BUILDING PAPER <br />WOOD 5HEATHING <br />DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />LAYER <br />Sn�cco WRAP <br />LAYER 4, FORTIFIBER <br />BUILDMYs PAPER <br />a�oNeTucTlaN <br />—METAL LATH <br />S' CMII VINYL CASING BEAD <br />W RAISED BAND <br />-WALL <br />WEEP HCI�ED <br />W WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />STOP VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER e2 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR '1/16' ZIP WALL <br />SPEATPING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / A5TM C-547-14a, MIN. 2.5 L55. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATP DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANI.F. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT O <br />TOP A SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALLI <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS-) <br />BUILDING PAPER, <br />UNDER 'QUICK FLASH' <br />—'WENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />_"-E <br />LEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIF15ER <br />BUILDING PAPER <br />j' THICK, 3 COAT CEMENT <br />PLASTER <br />V TO Ye' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />I-t_�I' WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />I50CYANOTE-POLY5LEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:;0 SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />�001 <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE V' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />LAYER q, <br />STUCCO WRAP <br />LAYER -2. FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />WOOD Ve' TEXTURED <br />CONSTRUCTION ; :y�FNIS14 • IJOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • I' D.C. MAX <br />e' Cm <br />V TON MID -WALL <br />IiCGP SCREED <br />• CT <br />6' WIDE 51WJP SELF <br />ADF- S fl_.ASWNG, CLEAN <br />.� MASONRY BEFORE APPLYING <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCKI <br />STEP *'3 <br />- <br />V <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER h, <br />STUCCO WRAP <br />APPLY 60 MIN <br />IWS <br />9 <br />_ GRADE 'D' FELT <br />® MEMBRANE FLA <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />_ METAL LATH <br />STEP #5 STEP "re <br />OELECTRICAL RECEPTACLE <br />L441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />` AA M: 0003325 <br />w <br />9 <br />N <br />C <br />2L2� <br />m <br />w <br />IN <br />0 <br />O <br />� <br />p <br />NN <br />Fr sXMDIV. de TAT: <br />ABBOTT PARK <br />LOT #7 <br />BLK. #9 <br />PROJECT# <br />04181.000-07091 <br />MODEL <br />4EHB <br />"2605—HAYDEN" <br />GARAGE 81111MG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 H IN. C <br />`;T'1!;T<YfK� <br />PRD4T 05/06/21 <br />DATE• <br />SCAT-9 1/4"=1'-0" <br />Yd <br />SHE�E�TT <br />A2 <br />