My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7864 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7864 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 9:20:23 AM
Creation date
2/24/2025 10:10:35 AM
Metadata
Fields
Template:
Building Plans
Street #
7864
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
1196
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />IIARD LAYER -1, <br />Slr=r6 WRAP <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />W42UE E OF FLASHING TO BE, <br />I. BOTTOM_ 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />61DES ONLY. SEALANT IS TO DE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON-MVA15LE FRAME AND STUC=O <br />ON ALL SIDE& V CAULKING a JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Extalor lofty and plaaEeft <br />Exterior use of portiand cement plaster <br />shall comply with the application <br />requirements of ASTM C 928-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1G63-12A. <br />HOODED VENT <br />I' THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WPM LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WR5 LAYER 02 (FORTIFIBER — — — • — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO 5E PER SECTION <br />R103.1.1 / ASTM C-841-0% MIN. 2.5 L56. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />ELEC. METEi <br />VERIFY LO <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER I <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (,BLOCK <br />BUILDING PAPER <br />OVER 'CIUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECSJ <br />BUILDING PAPER — <br />UNDER 'ClUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.B. <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />-ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO 5E FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COM50 OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />IUM LAYER 01, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOLISEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS Box, <br />APPLY TO FA <br />EDGE <br />APPLY E-Z <br />OVER SO MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />UM LAYER -1, <br />STUCCO WRAP <br />URS LAYER 7, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STIRUCTURAL <br />MEMBER • T' OTC. MAX <br />V TO)F MID -WALL <br />UEEP SCREED <br />6' Mom STRIP SELF <br />ADHESIVE FLASHMG, CLEAN <br />MASONRY BEFORE APPLYING <br />V FINISH • MASONRY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />B' <br />WRIS LAYER rl, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF-AD14ERNG <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHNG <br />OVER BOX AND OVER <br />APPROVED WM LAYER <br />h <br />STEP 01 <br />STEP #2 <br />ti <br />LATER 01, <br />WRISTUCCO <br />STUCCO WRAP <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />AP'ROVED <br />HOUSEWRAP <br />STEP #3 <br />El RMEMBRANE FLASHING <br />WRB LAYER O, POW F15ER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP #e <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />W W W.Sbdoslgngroup.com <br />AA A`: 0003325 <br />M <br />o <br />i <br />= <br />a <br />E+vaa:v. as IAT <br />ABBOTT PARK <br />LOT #22 <br />BLK #8 <br />PROJECT# <br />04181.000-22081 <br />MODZ <br />1401 <br />"DAKOTA" <br />Gw><ewGE awirrG: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />AA <br />NO <br />D � 10/16, <br />8CAIX: 1/4"=1'-0" <br />8HEET ^^ <br />WH2 <br />