My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7875 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7875 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 3:54:22 PM
Creation date
2/24/2025 10:07:11 AM
Metadata
Fields
Template:
Building Plans
Street #
7875
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
1057
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL. BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER MC 6TH EDITION (2011) MECHANICAL SLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL BI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS 614ALL HAVE AN APPROVED FIRE OR FIREAMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND 6E SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FSC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL SE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />BIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNI< <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS -THIRD AIR GRILL <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. CONDENSER <br />ATTIC <br />W/ (2)-3/I6'XT' TAPCONS UNIT <br />81M ISM WS ROLL STRAP <br />OR EQUAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUMARETUFN <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB <br />NBXI 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />REFR40RANTLINES <br />CONDENSER <br />UNIT <br />AIR HANDLERCONNECTION <br />TO PAD <br />EXTERIOR WALL3/4' <br />PVC CONDENSATE DRAIN LINE <br />NOTE: MAIN CCND. DRAIN 3/4' D14 <br />OVER HEAD • 12'FROM STRUCTURE <br />EVAP.TRAY <br />PVC SLEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />PLATFORM <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />k�/�MECHANICAL <br />FBCR 6TH EDITION (2011) <br />BLDG. CODE <br />SECTION 3013.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />WALL <br />COUNTERSUNK <br />CA. PLUG <br />�— SEE SPEC. <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 8240-K JOSAM 56000 <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYP. ) <br />FIN. GRADE <br />OR PAVING <br />1'-S'X8' CoNC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYPN <br />■ <br />NOTE. <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />MECHANICAL PLAN <br />SCALE= 1/4 . I'-0' <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-7748078 <br />FAX 407-7744078 <br />www.abdaslgngroup.wm <br />AA N: 0003325 <br />74 <br />a <br />t <br />3 <br />i <br />k <br />C <br />J <br />I <br />ac7HDM & L.OT: <br />ABBOTT PARK <br />LOT #18 <br />BLK #15 <br />PROJECT* <br />04181.000-18151 <br />MODET- <br />4EBB <br />"1828-CALI" <br />GARAGE 8717NO: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />160 MPH EXR C <br />•i X <br />PRINT 09/01mm <br />/20 <br />DATE: <br />8CAL.E: 1/4"=1'-0" <br />SHEET <br />M1 .04 <br />
The URL can be used to link to this page
Your browser does not support the video tag.