Laserfiche WebLink
locu5ign Envelope ID: 31288F87-6009-4E80-99F2-D36EA54752DD <br />INSULATION BAFFLE BETWEEN <br />TRUSSES INSTALLED PER MFR <br />WRITTEN SPECS <br />CONCRETE TILE ROOFING <br />INSTALLED PER MFR SPECS OVER VARIES (RE: \ <br />WD SHTHG OVER PRE-ENG WD OF PLAN) <br />TRUSSES (RE: STRUCTURAL) <br />ALUMINUM DRIP OVER <br />1x2 DRIP EDGE OVER <br />2x6 FASCIA W/ ALUMINUM WRAP <br />VENTED SOFFIT INSTALLED <br />PER MFR WRITTEN SPECIFICATIONS <br />NOTE: INSTALL PORTLAND 1 <br />CEMENT BASE PLASTER IN <br />ACCORDANCE WITH ASTM 926 <br />AND ASTM C 1063 <br />NOTE: INSTALL ALL VINYL CV <br />ACCESSORIES PER MFR <br />WRITTEN SPECIFICATIONS J <br />INSULATION BAFFLE BETWEEN <br />TRUSSES INSTALLED PER MFR <br />WRITTEN SPECS <br />VARIES (RE: 12� <br />ELEVATION) 1 I <br />��if-Af��&T&T&'��—���—�-1 ...... <br />►;%11 -- • <br />PER CODE <br />12" MINIMUM SAG RESISTANT <br />CEILING GYP BRD PER <br />FBCR TABLE R702.3.5 <br />POURED BOND BEAM <br />(RE: STRUCTURAL) <br />PRE CAST LINTEL <br />(RE: STRUCTURAL) <br />NOTE: RE: FLOOR PLAN (SH <br />A110/A120) FOR WINDOW SIZE. <br />RE: WINDOW MFR SPECS FOR <br />CODE COMPLIANCE AND <br />INSTALLATION DATA <br />2 TYP ONE-STORY WALL SECTION <br />A400 SCALE: 1" = V-0" <br />FIBERGLASS SHINGLE ROOFING — <br />INSTALLED PER MFR SPECS OVER <br />WD SHTHG OVER PRE-ENG WD <br />TRUSSES (RE: STRUCTURAL) <br />ALUMINUM DRIP OVER <br />1x2 DRIP EDGE OVER <br />2x6 FASCIA W/ ALUMINUM WRAP <br />VENTED SOFFIT INSTALLED <br />PER MFR WRITTEN SPECIFICATIONS <br />NOTE: INSTALL PORTLAND <br />CEMENT BASE PLASTER IN <br />ACCORDANCE WITH ASTM 926 <br />AND ASTM C 1063 <br />NOTE: INSTALL ALL VINYL CV <br />ACCESSORIES PER MFR <br />WRITTEN SPECIFICATIONS <br />%" THICK STUCCO FINISH - <br />TEXTURED PER COMMUNITY <br />SPECIFICATIONS <br />STUCCO PARGE COAT <br />GRADE (SLP AWAY FROM <br />STRUCTURE)(TYP ALL SIDES) <br />VARIES (RE: <br />GOOF PLAN) '. <br />I <br />r <br />VARIES (RE: 12 <br />ELEVATION) <br />/ <br />,•♦,IIIINSULATION PER CODE <br />•�i!i�J <br />12" MINIMUM SAG RESISTANT <br />CEILING GYP BRD PER <br />FBCR TABLE R702.3.5 <br />POURED BOND BEAM <br />(RE: STRUCTURAL) <br />PRE CAST LINTEL <br />(RE: STRUCTURAL) <br />NOTE: RE: FLOOR PLAN (SH <br />A110/A120) FOR WINDOW SIZE. <br />RE: WINDOW MFR SPECS FOR <br />CODE COMPLIANCE AND <br />INSTALLATION DATA <br />1/2" GYP BRD OVER <br />ALUMINUM FOIL INSULATION <br />W/ 1x2 TREATED FURRING <br />STRIPS at 24" O.C. MAX <br />1x TREATED FURRING TYP at <br />TOP & BOT OF BLOCK WALL <br />MAIN FIN FLR 0'-0" <br />° <br />z_ 4 <br />-- INSTALL VAPOR BARRIER <br />- IN ACCORDANCE WITH <br />ASTM E 1643-98 <br />FOUNDATION/FOOTING VARIES <br />(RE: STRUCTURAL) <br />CC TYP ONE-STORY WALL SECTION <br />A400 --- - — - — -- SCALE: 1 = V-0" <br />E <br />o O <br />o U <br />N <br />LO <br />� O <br />4 <br />C APEX <br />U <br />o � <br />rn � <br />N <br />N <br />M <br />w <br />J <br />_I <br />z t S <br />p true design studios <br />U <br />9000 REGENCY SQUARE BLVD. N� <br />o SUITE 100, JACKSONVILLE, FL 32211 c <br />r- <br />O <br />w <br />W <br />U <br />In <br />J U61HUMUN" N <br />m <br />LU <br />U _c <br />z <br />w <br />0 <br />0 <br />0 <br />�r <br />Ln <br />O <br />z <br />U) <br />co <br />w <br />z <br />w <br />U) <br />m <br />m <br />w <br />w <br />w <br />z <br />W <br />Z <br />C <br />C <br />w <br />Q <br />O <br />0 <br />Q <br />O <br />w <br />J <br />� <br />W <br />O <br />N <br />N <br />�`- Q <br />d <br />rz <br />O <br />U <br />X <br />Q <br />z <br />O <br />O <br />0 <br />Q <br />z <br />U ty <br />z a_ <br />0 - - w <br />O -- J <br />J Q <br />O U <br />z <br />PROJECT NO 0 <br />U w <br />w Q <br />IX DRAWN: U► <br />0- DVO <br />Q CHKD: --- W <br />TSD m <br />O <br />m <br />0 <br />0 � <br />w <br />O J <br />Q <br />W U <br />U) <br />z 0 <br />U) _z <br />o <br />i= <br />U <br />U <br />Q O <br />U) z <br />>_ REVISIONS: <br />0 No. Description Date o <br />O III <br />z U) <br />= w <br />W ~ <br />J <br />a U) <br />Q <br />A400 <br />O <br />0 <br />