My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7890 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7890 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 4:51:44 PM
Creation date
2/24/2025 10:07:51 AM
Metadata
Fields
Template:
Building Plans
Street #
7890
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
3432
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL 6' SELF -ADHERING <br />MEMBReWE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF T1E EXHAUST. <br />SEQUENCE OF FLASHNG TO BE: <br />I. BOTTOM. 2. SIDES, 3. TOP <br />1X: VENT CAP IS TO BE SET N BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED 80 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />x:r E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />' APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />Yi CAIILN KG • JOINT <br />AON <br />LL ALLSIDfES, <br />I <br />I I <br />PER SECTION <br />Extulor Mtl*w and pNahllrw <br />BACKER ROD <br />I I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />1 <br />X, <br />Installation of exterior lathing and flaming <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />UFO LAYER 9, <br />,.>. <br />STUCCO UAQAP <br />HOODED VENT <br />✓k THICK 3 COAT CEMENT <br />I <br />PLASTER <br />METAL LATH <br />URB LAYER "2. FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATWING <br />DRYER VENT <br />( FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER ------ <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR -1/16" ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R'103.1.1 / ASTM C-84-1-14a, MIN. 25 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />&' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHINCs <br />WIT <br />PREMANLP. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />9 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER *QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUP. SPECS) <br />BUILDING PAPER <br />UNDER 'QUICK PLASH' <br />0A VENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />ELEC. <br />METER FIELD <br />VERIFY LOCATION <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-C'GREAT STUFF" OR SIMILAR) <br />APPLY A SILICON <br />�j BASE SEALANT AT POINT <br />I THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />WOOD 044EAT14M <br />ORB LAYER 9, <br />STUCCO WRAP <br />WRS LAYER °2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FHO14 0 UIDDOD <br />-FASTEN TO WOOD STRUCTURAL <br />F EPIBM - T O.C. MAX <br />. A' TO JF MID _WA' <br />M 5cPwz f <br />1' Uwe STRIP amp <br />AD4ESNE FLAaHNG. CLEAN <br />MA60NRT OEFOW APPLYING <br />V FINISH - MASONZY <br />HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />8' <br />WRY LAYER 01, <br />CUT OPENING IN <br />STUCCO WRAP <br />- <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />CUT 'X'INTONJ <br />WRLAYER 01, <br />B <br />SELF -ADHERING <br />STUCCO WRAP <br />MEMBRANE FLASHING <br />APPLY SELF-ADHERfNG <br />WOOD SHEATHINCs <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB <br />LAYER 9 <br />STEP #1 <br />STEP <br />1*2 <br />APPROVED <br />LAYER 01, <br />BELOW <br />STUCCO <br />STUCCO WRAP <br />CUT SUCH THAT <br />9 <br />APPLY 60 MN <br />ING <br />NO MEMBRANE <br />__ <br />GRADE 'D' FELT <br />® <br />FLASHING <br />MEMfRANE FLASHING <br />MEMBRANE <br />ENTERS BOX, <br />OVER <br />APPLY TO FACE <br />SELF -ADHERING <br />EDGE <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />MRB LAYER 92, FORTIFIBER <br />BUILDING PAPER <br />STEP 1*3 <br />STEP <br />#4 <br />�-- <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />APPLY E-Z BEAD <br />SECTION) <br />OVER 60 MIN <br />GRADE 'D' <br />METAL LATH <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />STEP 05 STEP aro <br />@)ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PM: 407-774-6078 <br />FAX: 407-7744078 <br />www.aWea�ShBoup.com <br />AA M: 0003325 <br />04 <br />o <br />BUDDIV. ae Lo <br />ABBOTT PARK <br />LOT # 19 <br />BLK #8 <br />PHASE 2A <br />PRIoizcT�f <br />04181.000-19082 <br />MOD=.: <br />4EBB <br />"1828-CALI" <br />GAItAGIC 8111IINO: <br />RIGHT <br />PAGIC: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH FV. C <br />L) I <br />D � 12/07/21 <br />8CALIM 1/4"=1'-0" <br />sHSST <br />WA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.