Laserfiche WebLink
)ocuSign Envelope ID: 9B33A170-OA27-4470-819D-9FEBF6D1A704 <br />TYPICAL ROOF DECK <br />SHEATHING, SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENT <br />ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR <br />HTA16-18 W/ MIN (7) 10d x 1%" <br />IN TRUSS (NOTE: IF META12 <br />OR HTA16-18 IS IMPROPERLY <br />INSTALLED, ATTACH TRUSS <br />TO BOND BEAM W/ HTSM20 <br />• OR HTWM20) <br />—TRUSS TO TOP PLATE <br />FASCIA (SEE <br />W/ H2.5T OR RT7AT <br />ARCHITECTURAL) <br />OR SDWC15600, UNO MOISTURE BARRIER <br />C <br />ON PLAN BETWEEN MASONRY AND <br />PROPERLY WIND LOAD RATED <br />I <br />NON -PT LUMBER BY OTHERS <br />SOFFIT MATERIAL <br />VERT. REINFORCING TO <br />CONTINUOUS @ PERIMETER. <br />HAVE 10" STANDARD <br />SEE TABLE 1: COMPONENT <br />HOOK INTO BOND BEAM <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />COURSE CMU BOND <br />— • EVERY OTHER STUD TO TOP PLATE <br />H!& <br />B <br />BEAM W! #5 CONTINUOUS <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM <br />PLATE W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x— NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />%" THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/2' WEDGE BOLT W/ MIN 4'/2' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />-INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />Z <br />MOISTI <br />BARRIE <br />OTHER <br />(1) COE <br />CMU B <br />BEAM <br />CONTII <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x <br />I%" IN TRUSS (NOTE: IF META12 OR <br />HTA16-18 IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND BEAM W/ <br />HTSM20 OR HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 2 <br />TO TRUSS W/ MIN I <br />FOR MISLOCATIO <br />INSTALL NEW MAc <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />7CORNERS <br />CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x— NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />STEP DOWN TIE -BEAM <br />DIST FROM DOOR JAMB <br />/ WINDOW TO BLOCK <br />MIN. SCREW DIST. FROM DOOR JAMB <br />LENGTH / WINDOW TO BLOCK <br />MIN. SCREW <br />LENGTH <br />3/4" OR 11/4" <br />PER MANUF. 3" <br />5" <br />1 %. <br />31/4' 37 6 <br />5„ <br />115/6 <br />33/4, 33/„ <br />6„ <br />2 %4, <br />33/4" <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />O <br />OCy <br />O 0 <br />APEX <br />00 <br />O N <br />m <br />N <br />M <br />U_ <br />tds <br />J Q <br />J N <br />true design studios > <br />Z <br />O <br />G7 <br />U 9000 REGENCY SQUARE BLVD. c <br />Q SUITE 100, JACKSONVILLE, FL 32211 <br />cn <br />O <br />O <br />CA <br />W <br />041HO90 <br />• _ sV <br />LAj <br />• <br />w <br />a' <br />Q� <br />U <br />U <br />Z <br />W <br />W <br />w <br />O <br />O <br />O <br />O <br />ti u7 z <br />ti <br />Z O <br />W <br />co <br />W <br />Z Um Z W <br />co <br />J O Cn <br />a <br />w V Q <br />w <br />Z <br />(> C) Q <br />w W W <br />o(a) <br />J W <br />� W W <br />O <br />•� X <br />Z aO 0 <br />1= <br />w0 <br />a z <br />O a <br />U � <br />Abbott Park J <br />O U <br />J (n <br />U_ LOT 018-01 p <br />Q-----------w <br />H <br />U Q <br />Z_ Z <br />� O <br />Q PROJECT NO Uj <br />O Q <br />1 2021.003455 <br />Z O <br />DRAWN: - - - - - - - LDG o <br />U <br />LU CHKD: L0 <br />~ MJP <br />x <br />w w <br />a J <br />Q U <br />.��"%%% c;;I M LAA, '0 � i U) <br />�' G•ENS• .'9 �'� Z <br />m •� . _ <br />w ••• 00 <br />IRPR�ea bY: S <br />Z - r. <br />O r`I +i <br />W O I STATE OF : 1 <br />' .3FC4�71439z. <br />Z 0 N AL'E %%%% 'S <br />O 03-19-2021 p <br />f= w <br />U REVISIONS: w <br />Q No. Description Date <br />w <br />� U <br />-- p <br />Z — — <br />U � <br />Lu <br />H <br />X <br />ST=5 <br />a <br />rMI UMPTAI rnK1NF:rTnR PMrIMPPI17INIra <br />