7899 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7899 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:54:18 PM
Creation date
2/24/2025 10:15:17 AM
Metadata
Fields
Template:
Building Plans
Street #
7899
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
2339
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I3ocuSign Envelope ID: A4009781-616C-4779-89D3-82670B892C17 <br />BOND BEAM <br />REINFORCEMENT <br />J (SEE WALL SECTION) <br />0 <br />w FILL SOLID TO BOND BEAM <br />U <br />U) <br />W <br />W <br />co <br />o 0 <br />8 F - # DEPTH OF LINTEL <br />ASSEMBLY "d" <br />GROUT FILLED LINTEL ASSEMBLY <br />8" PRECAST LINTEL. SEE PLAN. <br />BOND BEAM <br />REINFORCEMENT <br />(SEE WALL SECTION) <br />COURSING BELOW BOND <br />� BEAM MAY BE FILLED OR <br />\i 1 UNFILLED <br />0 0 <br />8U8 <br />LINTEL MAY BE FILLED <br />OR UNFILLED <br />8" PRECAST LINTEL. SEE PLAN. <br />T BOND BEAM <br />REINFORCEMENT <br />J (SEE WALL SECTION) <br />0 <br />uj FILL SOLID TO BOND BEAM <br />U <br />U <br />W <br />W <br />co <br />LINTEL REINFORCEMENT <br />� o 0 <br />8 F -1 - #—DEPTH OF LINTEL ASSEMBLY "d" <br />#5 BOTTOM BAR TO EXTEND <br />NO LESS THAN 1" BEYOND <br />BEARING AT EACH END <br />GROUT FILLED LINTEL ASSEMBLY <br />8" PRECAST LINTEL. SEE PLAN. <br />8F-1-# <br />TYPICAL PRE -CAST LINTEL OPTIONS <br />MOISTURE BARRIER <br />BY OTHERS <br />TYPICAL PORCH SHEATHING DETAIL <br />AT MASONRY EXTERIOR WALL <br />(THIS DETAIL IS REQUIRED AT ALL COVERED <br />PORCHES UNLESS NOTED OTHERWISE) <br />8'-1" ABOVE <br />F.F.E. <br />i <br />TOP OF OIL <br />GARAGE DOOR <br />6-1" ABOVE OIL <br />F.F.E. <br />4'-9" ABOVE <br />F.F.E. <br />2'-9" ABOVE <br />F.F.E. <br />rLOF OPENING <br />2x6x12 PT <br />CENTER BUCK <br />%" DIA. ANCHOR <br />2x4 PT TOP BUCK <br />2x6 PT BUCK EACH SIDE OF OPENING <br />- PROVIDE (5) %" DIA. J-BOLT OR <br />DIAMETER SCREW ANCHOR w/ 5 <br />EMBEDMENT AT EACH DOOR BRACKET, <br />EACH SIDE OF DOOR. PROVIDE 2" SQ x, <br />THICK WASHER w/ EACH ANCHOR. <br />(1st BOLT TO BE 9" MAX. ABOVE CURB.) <br />GARAGE DOOR JAMB DETAIL <br />TOE -NAIL MIN 2x4 NO.2 SYP BLOCKING <br />BETWEEN TRUSS TOP CHORDS W/ <br />(3) 10d COMMONS EACH END <br />FASTEN 2x6 NO.2 SYP— <br />DIAGONAL BRACE TO <br />BLOCKING w/ (6) <br />10d COMMONS <br />2x6 NO.2 SYP DIAGONAL BRACt7 <br />SEE PLAN <br />• UP TO 8FT SINGLE 2x6 ONLY <br />• UP TO 20 FT, 2x6 W/ 2x6 T-BRACE <br />FASTEN 2x6 NO.2 SYP <br />"T-BRACE" TO DIAGONAL BRACE <br />w/ 10d COMMONS @ 3" O.C. <br />BLOCK PANEL EDGES <br />WITHIN 4'-0" OF GABLE <br />TRUSS (EDGEWISE <br />OR FLATWISE) <br />PROVIDE PANEL <br />EDGE BLOCKING FOR <br />NON -DROPPED GABLE <br />11, <br />8'-0" OR AS SHOWN ON PLAN <br />FASTEN (1) SIMPSON HGAM10 BRACE CONNECTOR <br />FROM DIAGONAL BRACE TO CMU <br />MOISTURE BARRIER BETWEEN MASONRY <br />AND NON -PT LUMBER BY OTHERS <br />1) MAX. TRUSS SPACING = 24" O.C. <br />2) OUTLOOKERS, BLOCKING & CLIPS MAY BE OMITTED FROM <br />OVERHANG PORTION OF DETAIL FOR NON -DROPPED GABLE <br />TRUSSES W/ 9" OR LESS OVERHANGS. <br />FASTEN ROOF DECK TO <br />FRAMING @ 3" O.C. ON <br />EDGE, 6" O.C. IN FIELD <br />WITH RSRS-01 <br />ROOF DECK <br />ROOFTRUSS <br />OR RAFTER <br />SUB FASCIA <br />MOISTURE BARRIER <br />BY OTHERS <br />MASONRY LINTEL <br />PER PLAN <br />2x4 SYP OUTRIGGER @ 24" O.C. <br />CLIP TO GABLE TOP CHORD WITH <br />(1) H2.5T w/ (10) 8d x 1 %Z' <br />2x4 NO.2 SYP BLOCKING BETWEEN <br />OUTLOOKERS. FASTEN EACH <br />BLOCK TO ROOF DECK WITH 8d <br />COMMON @ 3" O.C. <br />GABLE TRUSS <br />WALL SHEATHING PER PLAN <br />L OR T BRACE VERTICAL <br />REINFORCEMENT PER <br />TRUSS ENGINEERING <br />MOISTURE BARRIER SHALL BE <br />PROVIDED BETWEEN MASONRY <br />AND ALL UNTREATED LUMBER <br />GABLE TRUSS TO BOND BEAM W/ <br />META20 @ 48" O.C. W/ MIN (7) 10d x 1 %" <br />(NOTE: IF META20 IS IMPROPERLY <br />INSTALLED, ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR MSTAM36) <br />(1) DIAGONAL BRACE PER (10) TRUSSES APPLIED TO <br />OPPOSITE SIDE OF WEBS. DIAGONAL BRACE APPLIED AT <br />APPROXIMATE 45' ANGLE TO NO LESS THAN (3) TRUSSES. <br />II II II II <br />CONTINUOUS LATERAL RESTRAINT <br />(CLR). QUANTITY AND LOCATION <br />DEFINED BY TRUSS SHOP DRAWING. <br />APPLIED TO EITHER IF LATERAL RESTRAINT MUST BE <br />SIDE OF WEBS MADE OF MORE THAN ONE PIECE, <br />DO SO WITH OVERLAPPING <br />BRACES LIKE THIS (TYP <br />EVER HERE) <br />TRUSSES NEEDING BRACING <br />LATERAL BRACING - MULTIPLE TRUSSES <br />1. ALL RESTRAINT LUMBER SHOWN SHALL BE 2x4 NO.3 SPF OR BETTER (UNO). <br />2. SHOULD A SCENARIO ARISE THAT DOES NOT RESEMBLE THOSE INDICATED ABOVE, IMMEDIATELY <br />CONTACT THE ENGINEER OF RECORD FOR APPROPRIATE BRACING DETAILS. <br />3. BRACING LUMBER SHALL INTERSECT THE WEBS OF THE BRACED TRUSS AT LOCATIONS INDICATED AS <br />NEEDING BRACING ON THE INDIVIDUAL TRUSS DETAILS PRODUCED BY THE TRUSS ENGINEER. <br />4. ALL FASTENERS SHOWN ARE .131" x 3" LONG (UNO). <br />5. DESIGNED PER BCSI-B3. 2007. <br />T-BRACE FASTENED TO <br />WEB W/ 10d AT 6" O.C. <br />L-BRACE FASTENED TO <br />WEB W/ 10d AT 6" O.C. <br />�— SCAB BRACE FASTENED TO <br />WEB W/ 10d AT 6" O.C. <br />`IF (2) BRACES ARE <br />REQUIRED, APPLY (1) BRACE <br />_Te" MAX TO EACH FACE OF WEB. <br />TOP OF WALL <br />CONTINUOUS LATERAL RESTRAINT WEB <br />BRACE SUBSTITUTE <br />WEB MEMBER <br />SPECIFIED <br />ALTERNATE BRACING <br />SIZE <br />CLR <br />T OR L SCAB <br />2x4 1 ROW <br />2x4 (1)2x4 <br />2x4 2 ROWS <br />2x6 1 ROW <br />2x6 2 ROWS <br />2x6 (2)2x4` <br />2x4 (1)2x6 <br />2x6 (2)2x4` <br />2x8 1 ROW <br />2x6 (1)2x8 <br />2x8 i 2 ROWS <br />12x6 (2)2x6` <br />SINGLE TRUSS BRACING <br />1. INDIVIDUAL WEB BRACING MAY BE USED WHEN CONTINUOUS LATERAL <br />RESTRAINT (CLR) IS SPECIFIED ON A TRUSS DESIGN BUT AN <br />ALTERNATIVE WEB BRACING METHOD IS DESIRED. <br />2. INDIVIDUAL WEB BRACING MAY CONSIST OF T-BRACING, L-BRACING, OR <br />SCAB BRACING. REFER TO CHART AND DETAIL FOR MORE INFORMATION. <br />3. INDIVIDUAL WEB BRACING MATERIAL TO BE SAME SIZE, SPECIES, AND <br />GRADE AS WEB TO BE BRACED. <br />---�-L ------- ----- <br />i <br />i <br />VERTICAL BARS TO EXTEND TO <br />TOP OF WALL AS SHOWN. MIN <br />6" BEND INTO BOND BEAM <br />AST LINTEL SEE <br />EXTEND REINFORCING TO <br />END OF PIER W/ 6" BEND TO <br />LAP WALL REINFORCING AS <br />SHOWN. <br />MIN (2) SOLID FILLED & <br />REINFORCED CELLS W/ NO.5 <br />VERT. BAR ADJACENT TO <br />GARAGE DOOR OPENINGS. <br />NO.5 VERT. BAR IN FILLED <br />CELL AT EACH END OF PIER <br />NO. 5 DOWEL TO MATCH EACH <br />SOLID FILLED & REINFORCED <br />CELL EXTENDING FROM FOOTING <br />TO LAP WALL REINFORCING <br />W/ MIN 25" LAP UNLESS NOTED <br />OTHERWISE ON DOWEL & LINTEL <br />PLACEMENT PLAN. MIN 6" BEND <br />AT BOTTOM. <br />CONCRETE <br />FOUNDATION WORK <br />PER PLAN <br />--------- - - - - - - - <br />i <br />i <br />GARAGE SHEAR PIER <br />O <br />LO Lt U <br />f` <br />O O <br />cy <br />U) APEX _c <br />(0 U <br />W N <br />Z <br />d) <br />to <br />m <br />W <br />W <br />Z <br />C9 <br />Z tds -6 <br />W <br />QQ true design studies (D <br />O <br />LL 9000 REGENCY SQUARE BLVD. N <br />SUITE 100, JACKSONVILLE, FL 32211 <br />ch <br />904.821.5200 p <br />Q <br />O � <br />O <br />041HOBON, <br />U � <br />• <br />rY <br />O <br />J •• <br />LL <br />Q � <br />U <br />Z <br />} <br />O <br />J <br />O <br />Z <br />2 <br />w <br />F- <br />x wW <br />Q <br />0 co <br />m 11111111111101111111 z <br />o �'W/^'� <br />W O VJ Z <br />0 a <br />W O <br />z m > o <br />Z a J W <br />M W W Q <br />� � o <br />U LL W <br />C <br />ti <br />} <br />x <br />c� <br />o z <br />J O <br />O <br />Z W <br />2 � <br />U Z <br />Abbott Park <br />x n- <br />W W <br />a LOT 013-03 w <br />Q - -j <br />Q <br />U <br />U) <br />0 <br />PROJECT NO. <br />2021.006634 z <br />0 <br />DRAWN: W <br />JAR W <br />CHKD: <br />MJP 0 <br />IR <br />O <br />u7 <br />J <br />U <br />No 85166 (A <br />DopuSigned by: U) <br />T.RCw� �1 C Z <br />i O •' F4@71 [11tCDEF43� �1` <br />• �L <br />05-18-2021 O <br />_z <br />REVISIONS: <br />No. Description Date <br />W <br />W <br />W <br />Q <br />U <br />F- <br />O <br />Z <br />=6 O <br />CMUIMETAL CONNECTOR ENGINEERING <br />- <br />:�}:.y . �.-,��d'.t-rx.-i ._— �.� ..` .: '�. L= ._ ..r i >"t _an r.-.�.`.-:y - <br />