My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7904 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7904 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:05:09 PM
Creation date
2/24/2025 9:33:46 AM
Metadata
Fields
Template:
Building Plans
Street #
7904
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
2345
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
6' <br />FLANWS, OF NON -MOVABLE <br />FRAME OF THE 004Au6T. <br />waENCE OF PLA&HNG 70 BE: <br />I. BOTTOM, 2. SIDES. 3. TOP <br />VENT CAP 16 TO BE SET IN BED <br />J <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 16 TO BE <br />TOOLED 60 AS TO DELECT <br />WATER AWAY FROM JOINTS. <br />E-2 BEAD ALL AROUND <br />VE ff-APPLY SEALANT ALL <br />JOINT& AND INTERSECTIONS <br />r <br />APPLY SEALANT AT PERIMETER OF <br />BACKER ROD <br />NON-MOVABLEFRAME AND STUCCO <br />CAULKING b JOINT <br />I <br />I <br />AZI-l. AR01��6' <br />i I <br />PER SECTION <br />i I <br />6Ar1oT kftw Snd olSalarNla <br />BACKER ROD <br />I I <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />-1t(, <br />1 <br />r'. <br />installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />WRB LAYER 9, <br />STUCCO uN¢AP <br />HOODED VENT <br />��3 COAT CEMENT <br />7 <br />C: <br />METAL LATH <br />WRB LAYER n, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHIING <br />DRYER VENT <br />(FRAME) <br />WOOD SHEATHING <br />LAYER H <br />STUCCO WRAP <br />LAYER •1, FORTIFIER <br />BUILDING PAPER <br />coNa�nicTloN <br />—METAL LATH <br />a' CM VINYL CASINO DEAD <br />6' RAISED BAND <br />`� . li' TO Jf' tlID�119LL <br />W UNDE STRIP SELF <br />ADHESIVE Pt.ASHINIA CLEAN <br />MASONRY OP —POPE APPLYING <br />Z FLAlHIRG <br />STONE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W,/STONE VENEER <br />( FRAME TO BLO C KI <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — - — - — - — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHE <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-103.1.1 / ASTM C-84-7-14a, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PFM ANUF, DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THI60UGH <br />tU,4LL <br />1 <br />6' SELF ADHESIVE— <br />PLASHNG (INSTALL <br />PER MLANUIF. SPECS.) <br />BUILDING PAPEI <br />UNDER 'QUICK FLASH <br />A VENT PENETRATION <br />SCALE. NT.B. <br />ELEC. METEF <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRS LAYER P, <br />STUCCO WRAP <br />WRS LAYER 02, FORTIFISER <br />BUILDING PAPER <br />3 COAT CEMENT <br />X' TO V MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />I _1_� ' � WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE lU LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />I -- .--' SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />A SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />UM LAYER <br />STUCCO M <br />WOOD SHEATHING <br />HOUSEW RAP <br />BELOW <br />CUT &UCH TWAT - <br />NO 1'9EMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-z DEAD <br />OVER 60 MN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />NTERBECTIONS <br />WOOD SHE,ATHIING <br />um LAYER M, <br />STUCCO ~ <br />METAL LATH <br />wow I/ <br />CI"T1 =WIN FMIS� <br />PAS <br />T1aN TO WOOD STRUCTURAL <br />MEMBER MAX <br />a• eru <br />PSI <br />q T. <br />— L <br />b' WOE STRIP SELF <br />ADNEaNE PLASHIIYs, CLEAN <br />MASONRY D®ORE APPLYRI6 <br />V FINISH • MASONRY <br />® HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCKI <br />6' <br />WRIS LAYER 01, <br />STUCCO WRAP <br />. :,:::�:....�:..�....: <br />WRO LAYER 01, <br />STUCCO WRAP <br />9 <br />_ <br />APPLY 60 MN <br />GRADE 'D' FEL T <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLA6HNCs OVER <br />APROVED <br />HOUSEWRAP <br />WRB LAYER 02, FORTIFIEIER <br />BUILDING PAPER <br />STEP *3 <br />STEP <br />*4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ CT/. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 ST = #(o <br />l 9) ELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN SLVD. <br />LONGWOOD, FL 32760 <br />PH: 407-77448078 <br />FAX: 407-7744078 <br />www.abdoeigngroupcom <br />AA 9: 0003326 <br />S3 <br />b <br />IBUNWIV. & LOT: <br />ABBOTT PARK <br />LOT #3 <br />BLK #9 <br />noizCT# <br />04181.000-03091 <br />MODRITA <br />4EAB <br />"1672-ARIA" <br />GARAGE B1111IING: <br />RIGHT <br />PADS: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />
The URL can be used to link to this page
Your browser does not support the video tag.