7905 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7905 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:16:41 PM
Creation date
2/24/2025 9:37:44 AM
Metadata
Fields
Template:
Building Plans
Street #
7905
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
2213
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL 15E SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC TTH EDITION (2020) MECHANICAL BLDG. CODE SECTICN 603. <br />3. ALL FLEX DUCTS SMALL BE APPROVED UL 181 CLASS 1 AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC ITH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FSC 1TH EDITION <br />(2020) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC NTH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S ALL FIRE RATED CEILINGS AND WALLS 1}14ALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. REC0MRIENDATIONS AND PBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SMALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH OBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />CEILING <br />PLENUM <br />AIR SUPPLY <br />AIR HANDLER <br />EVAP.TRAY <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />BRASS PLUG <br />INSIDE <br />CAULK <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />1010 <br />EXTERIOR WALL <br />AIR RETURN <br />ON AND LIQUID <br />IGERANT LINES <br />WALL <br />6LEXTERIOR <br />VC CONDENSATE DRAM LINE <br />LEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 'ITN EDITION 12020) <br />MECHANICAL BLDG. CODE <br />SECTION 301.2A <br />HVAC <br />DRAINS <br />FIN. FLOOR <br />OR WALL <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 6240-K JOSAM 86000 <br />SERIES NICKEL BRASS TOP <br />P.V.0 OPT[/SPEC <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LIKE- SUPPLY TRUNK <br />BROKEN LIKE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PA86-THM AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/16'X2' TAPCONS UNIT SIMPSON WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />PDX] 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE: MAIN COND. DRAM 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUW <br />CA. PLUG <br />FM. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'XS' GONG. <br />FITTING OR <br />EXTENSION TO 801E <br />OR WASTE AS <br />REQUIRED <br />FLOOR SLAB CLEAN -OUT (TYPN) OEXT. GROUND CLEAN -OUT (TYPNT� <br />MECHANICAL PLAN <br />SCALE, 1/4 - I'-0' <br />NOTE: <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />1441 Ni RONALD REAGAN BLVD. <br />LONGWOOD,FL32750 <br />PH: 407-7746078 <br />FAX: 407-774-4078 <br />www.abdealgngroup.wm <br />AA M: 0003325 J <br />a <br />kbk <br />6 <br />kbk <br />6 <br />eXMDIV. & LOT <br />ABBOTT PARK <br />LOT #16 <br />BLK. #7 <br />P1iOJSCTp <br />04181.000-16071 <br />MOD1ELa <br />4EBB <br />"1828-CALI" <br />OARAOS 9WWO: <br />LEFT <br />PACE: <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />1 <br />:< � <br />DRINT <br />AB., 5/05/21 <br />SCALE: 1/4"=1'-0" <br />$BEST <br />M1 <br />