My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7917 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7917 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 7:51:09 PM
Creation date
2/24/2025 10:12:25 AM
Metadata
Fields
Template:
Building Plans
Street #
7917
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
1059
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F 7 <br />3'-6" <br />33'-10 <br />4 31/2" I <br />4 <br />4' CONC. <br />I 4" I <br />4 <br />SLAB <br />CONC. <br />3 <br />T�Op pF ;�.� <br />Iw <br />wl UaJ ri SLAB1.1 <br />SLAB <br />o a r <br />FM-12X18 — — — — <br />— — — — <br />— — — <br />— <br />— — — — <br />I <br />TOP Of <br />z <br />SLAB <br />o <br />U 7 <br />4" PVC � <br />mi <br />O <br />`v <br />I CHASE <br />I <br />i� <br />lk <br />a <br />I <br />26'-9" <br />I <br />1 V-3" <br />N <br />I <br />I' <br />• I <br />I <br />1 <br />I <br />EXTEND <br />TE2 <br />SLAB 1 1/2" I <br />J <br />— — — — <br />.I I <br />II 9,_5. <br />2,_8. <br />8,_i. iv <br />I� *-51/2" <br />I <br />5 <br />I Lu <br />W <br />I <br />m <br />O 4"CONC� W <br />u <br />• I Iw SLAB <br />I n. w <br />33 <br />IN *1/2"; <br />1 J <br />, <br />SLABEXTEND1/2" <br />2 <br />• I FM-12X1J <br />I � _ W� <br />I. <br />1/2" <br />L1 1.1 g 3A. 5" fMC- 4 § <br />4 FMG <br />L FM-12X18 _ _ J 12X18 1.1 FM - <br />— — — — <br />1.1 12X78 <br />— — <br />fl <br />LA TE1 <br />8'.0" <br />FOUNDATION PLAN <br />SCALE: 1/4" = 1'-0" <br />16'-0" <br />FOUNDATION NOTES <br />1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR <br />COMPACTING REQUIREMENTS. <br />2. TOP OF FINISHED SLAB SHALL BE +4-0". <br />3. COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED <br />OTHERWISE. <br />4. REFERENCE ELEVATION -0'-0", SEE SURVEY PLOT FOR NAVD. <br />S. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES, TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS <br />ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER <br />SERVICES. <br />6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: <br />PROVIDE 1/2" FELT PAPER AT THE JOINT. <br />7. COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL <br />DRAWINGS. <br />8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING. <br />9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE <br />WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS <br />AND WITH THE MANUFACTURES SPECIFICATIONS. <br />10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT. <br />11,MINDICATED #5 BAR, DINDICATES #6 BAR,■NDICATES #7 BAR VERTICAL <br />REINFORCING BAR IN CELLS FILLED WITH GROUT, ENDS OF REINF. BARS SHALL BE <br />HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 90° <br />HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. <br />12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = <br />30". #6 =36"), AND REINFORCING SHALL BE CONTINUOUS. <br />13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL <br />REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE <br />SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS <br />BEEN DELETED UNLESS NOTED OTHERWISE. <br />14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS <br />OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: <br />A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION <br />C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS <br />15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, BUILDING <br />CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. <br />CONSTRUCTION SHALL BE IN ACCORDANCE WITH A.C.I. 530-13/ASCE 5-13, USING: F m _ <br />1.500 PSI, TYPE "M" OR"S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN <br />RUNNING BOND. <br />16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER 4 OF SLAB SUPPORTED <br />3'-0" O/C MAX. SEE PLAN FOR W WM SIZE. <br />INSPECTOR NOTE: <br />1. STRUCTURE WAS DESIGNED BASED ON THE 2017 FLORIDA RESIDENTIAL BUILDING <br />CODE, RESIDENTIAL, 6th EDITION <br />SLAB SCHEDULE <br />SLAB <br />I THICKNESS <br />REINF. <br />REMARKS <br />64 W I AXW 1.4 OVER <br />GENERAL <br />3 112" <br />6 MIL VAPOR <br />COMPACTED FILL <br />BARRIER <br />FOOTING SCHEDULE <br />PROVIDE CORNER BARS, SAME SIZE QUANTITY AS BARS IN FOUNDATION WITH 30" LEG EACH WAY. <br />WIDTH <br />LENGTH <br />THICKNESS <br />BOTTOM REINF. <br />TOP REINF. <br />T.O.F. <br />SHORT <br />LONG <br />N <br />,• <br />(1)#5's <br />(+)0'-0" <br />12" <br />SEE PLAN <br />8" <br />(2) #5's <br />(+)0'-0" <br />MFMC12xl8 <br />12" <br />CONTINUOUS <br />16" <br />(2)A's <br />(+)0'-0" <br />12" <br />CONTINUOUS <br />18" <br />- <br />(2)#5's <br />VARIES <br />24" <br />24" <br />12" <br />(2) #5's <br />(2) #5's <br />(-)0'>" <br />1441 N. RONALD REAGAN Bt <br />LONGWOOD, FL32760 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.00m <br />AA #: 0003326 <br />M <br />94 <br />14 <br />04 <br />atmDm & LOT <br />ABBOTT PARK <br />LOT #14 <br />BLK #15 <br />PROJECTI# <br />04181,000-14151 <br />MODIR 1408" <br />"DAKOTA" <br />GARAGE SWING: <br />RIGHT <br />PAGE: <br />FOUNDATION <br />PLAN <br />160 MPH EXP. C <br />DRINT <br />A 08/31/20 <br />aCALJB: 1/4"=1"-0" <br />81-MET <br />s1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.