'♦I ?ocuSign Envelope ID: B403F602-5BE34C26-8ECA-153BOD7D413C <br />EXISTING EXTERIOR CMU <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />MIN. 6" BELOW GRADE. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6' DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />° -- <br />° p .� D <br />D ° <br />D <br />D EXISTING FOUNDATION. <br />D ° <br />° D <br />I n -- <br />D. <br />8" CMU WALL OVERHANGS LESS THAN 1" <br />GROUT BOTTOM 3 COURSES <br />OF EXISTING CMU WALL FOR <br />LENGTH OF OVERHANG. FILL <br />TO BOTTOM OF WINDOWSILL <br />WHERE NEEDED <br />MIN. 3" EDGE DISTANCE <br />STRIP OF WWF FROM F.F.E. TO <br />BOTTOM OF FTG. WWF TO <br />EXISTING FOUNDATION FACE w/ <br />(2) ROWS OF 3/6" DIA. TAPCONS <br />OR CUT NAILS @ 24" O.C. COVER <br />FLUSH w/ 3000psi CONCRETE. <br />D <br />D D <br />D EXISTING FOUNDATION <br />I <br />D <br />8" CMU WALL OVERHANGS 2.5" OR LESS <br />NOTES: <br />• IF EXISTING REBAR DOES NOT MEET 3" EDGE DISTANCE REQUIREMENT, <br />REMOVE INSIDE FACE SHELL OF EXISTING CMU WALL AT ADJECENT CELL <br />AND DRILL & EPDXY NEW FULL HT. VERTICAL #5 DOWEL W/ 12" EMBED INTO <br />EXISTING FOUNDATION AND 4" EMBED INTO EXISTING BOND BEAM. <br />• IF MORE THAN (3) BARS DO NOT MEET THE REQUIRED 3" EDGE DISTANCE, <br />CONTACT EOR. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />° - - - (MAX 20" <br />4 ° ° ° ° - DEEP) <br />EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />cBEARING CURB STEP SECTION <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />\/\\/�\/�\/\\j/\\//\° ° ° ° ° a �\\;\\/�\ N <br />\/\\ 4 ° <br />4 <br />16" VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />L-- <br />CONTINUOUS CONCRETE <br />FOOTING, SEE PLAN <br />LAP #5 CONTINUOUS BAR AS <br />NEEDED, MIN 12" LAP AS SHOWN <br />NO.5 BAR BEND 90 DEGREE <br />TYPICAL STEP IN FOOTING DETAIL <br />8" CMU CHAIR BLOCK W/ (1) #5 ----\ <br />CONTINUOUS TO EXTEND MIN 24" <br />INTO MONOLITHIC THICKENED EDGE <br />U) <br />- ---- <br />of <br />- <br />OU <br />UZ <br />Rr <br />i@ <br />° <br />--, <br />- <br />4 . <br />LOCATE VERTICAL <br />REINFORCEMENT IN LAST <br />STEMWALL CELL <br />NO LITHIC SLAB <br />MIN 24" LAP <br />4" CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />- i - - _ OR FIBER MESH <br />#4 OR #5 <br />REINFORCING PER <br />° <br />° ° MONOLITHIC FOOTING <br />° ° SECTION <br />FOOTING TO BEAR ON FIRM ° <br />a° UNDISTURBED SOIL <br />° °° MIN 112"4_A <br />. STEMWALL FOOTING TO EXTEND MIN <br />12" BELOW MONOLITHIC FOOTING <br />• ADDITIONAL #4 OR #5 VERTICAL TO BE <br />LOCATED WITHIN TRANSITION ZONE <br />AND TIE INTO STEMWALL FOOTING <br />REINFORCEMENT <br />CMU STEMWALL TO MONOLITHIC TRANSITION DETAIL <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />TOP OF SLAB <br />co <br />VAPOR BARRIER \ <br />� o L' <br />#4 OR #5 VERT REINFORCING - \ /\\ <br />UP TO 3 COURSES: 72" O.C.\\� <br />4 TO 5 COURSES: 48" O.C. IN <br />8" CMU CHAIR <br />BLOCK W/ (1) #4 OR #5 CONT. <br />ADDITIONAL #4 OR <br />FOOTING TO BEAR ON FIRM #5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />0'-0" A.F.F. Ak <br />(BEYOND) <br />FLOATING CONCRETE _w U-BLOCK W/ <br />SLAB W/ 6x6 W1.4xW1.4 U U) (1) #4 OR #5 <br />WWF OR FIBERMESH > e .y Q ¢ w CONT <br />uJ uJ U) � FINISH <br />GRADE <br />c) r K7-7 <br />#4 OR #5 VERT REINFORCING - \ 1 <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C. / <br />n <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL ADDITIONAL OR <br />#5 IN BRICK LEDGE <br />E <br />VERT REINFORCEMENT TO 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />CONT. 3'/2' CONCRETE SLAB W/ 6x6 <br />(1) #4 OR #5 W1.4 x W1.4 WWF OR FIBERMESH <br />MINIM 24" (1) #4 OR #5 90° BEND @ 48" O.C. <br />VARIES PER <br />36" MAX ARCH PLANS ° 4 a //\\//\ ' <br />12" MIN �/ ° '\ VAPOR BARRIER <br />/ / FOOTING TO BEAR ON FIRM <br />� I / UNDISTURBED SOIL <br />6" OPT. EXTENSION b / <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL W/ (2) <br />ADDITIONAL NO.4 OR NO. 5 #4 OR (2) #5 CONT <br />BAR IN BRICK LEDGE - <br />16" UNDER 2 STORY WALL W/ (3) <br />1#4 OR (2) #5 CONT <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />'NOTE.. IT IS ACCEPTABLE TO SUBSTITUTE THIS., <br />HIS "1A" FTG DETAIL FOR THE "1" <br />FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN V-0" VERTICALLY PER T-O" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />SEE NOTES (MAX 16") v <br />0 <br />STUCCO OR DIRECTLY ADHERED Ci <br />STONE CLADDING FINISH - MIN 6" > <br />a D n ALL OTHER EXTERIOR WALL N O <br />\ \ \ \T�/T\T o CLADDING - MIN 8", U.N.O. ON ARCH <br />,\ \ \ \ \ \ _ O <br />O cy <br />VAPOR BARRIER \%\\ /\ N O <br />A\\ 1?" MIN\\/\\/\\/\\/\\/ LO <br />APE <br />00 N <br />O N <br />FOOTING TO BEAR ON / 6" OPT. EXTENSION IN BRICK O <br />FIRM UNDISTURBED cu <br />LOCATIONS ON FND PLAN <br />SOIL <br />12" UNDER 1 STORY WALL wl �(Vv <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 M � <br />BAR IN BRICK LEDGE J <br />16" UNDER 2 STORY WALL w/ LL <br />(2) #5 OR (3) #4 CONTINUOUStds J .Q <br />1 MONOLITHIC FOOTING SECTION true design studios °) <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE Z <br />FOLLOWING OCCUR: O <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" 07 Z� <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY U 9000 REGENCY SQUARE BLVD. <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Q SUITE 100, JACKSONVILLE, FL 32211 <br />PER T-O" HORIZONTALLWO PREVENT EROSION OF SOIL. O_ <br />O � <br />CONCRETE SLAB w/ 6x6 O <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR CA <br />FIBERMESH W <br />N ° <br />/ <br />16" VAPOR BARRIER LU zz <br />Qcl <br />0 <br />U <br />3 BEARING WALL FOOTING SECTION 0 <br />z <br />W <br />CONCRETE SLAB W/ 6x6 0 <br />W1.4 x W1.4 WWF OR W <br />FIBERMESH w <br />0'-0" A.F.F. O <br />a 4 SEE ARCH O <br />` a \° DETAILS a? <br />8" MIN LO <br />zU)8"x8" THICKENED 8" W <br />FTG AT <br />STEP-DOWN, EE VAPOR BARRIER (L%j Q <br />PLAN Wz LL <br />r CURB STEP SECT -ION <br />Z W <br />4 N_ m o cn <br />8" UNDER MASONRY WALL w <br />W <br />Z oCONCRETE SLAB W/ 6" UNDER WOOD WALL _ 0 Q Q <br />6x6 W1.4 x W1A WWF <br />OR FIBERMESH VARIES ° W W W <br />j SEE ARCH W <br />- -- - - - ° (MAX 16") <br />--- o --4 4,° W W <br />o <br />/� X <br />12" MIN./\/\/\/\/\/ LL <br />VAPOR BARRIER O Z <br />\\ <br />6" OPT. EXTENSION IN BRICK <br />LOCATIONS ON FND PLAN W <br />12" UNDER 1 STORY WALL w/ IZ Z <br />(2) #5 OR (2) #4 CONTINUOUS - ADDITIONAL NO.4 OR NO. 5 <br />-- BAR IN BRICK LEDGE 0 0- <br />16" UNDER 2 STORY WALL w/ LL. <br />(2) #5 OR (3) #4 CONTINUOUS Q W <br />0 Q <br />Abbott Park <br />5 GARAGE EXT WALL CURB SECTION - <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE O 07 <br />FOLLOWING OCCUR: Q LOT 016-01 0 <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY V Q <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY Z Z <br />PER T-O" HORIZONTALLYTO PREVENT EROSION OF SOIL. - 0 <br />} U) <br />CONCRETE SLAB W/ 6x6 PROJECT NO: W <br />W1.4 x W1.4 WWF OR 0 0 <br />FIBERMESH 2O21.003454 LL <br />0'-0" A F F O Q <br />--- MAX 20CH = DRAWN: - - <br />4 ° 7-DEEP) U LDG O <br />\\\�\\ j/\ K 4, w MJP w <br />4" EXTENSION a J <br />- UNDER BRICK VENEER a U <br />(n <br />12" UNDER 1 STORY WALL <br />w/ (2) #4 OR (2) #5 CONT VAPOR BARRIER m `,���� �JS�G E N S� ,9 �•,�� Z <br />16" UNDER 2 STORY WALL 0 • Qmi1t;S1dl <br />#4 OR (2) #5 CONT W 9 * �y'� <br />Z .. <br />6 <br />BEARING CURB STEP SECTION _ o <br />O • Al`� O F :• �/ ` <br />y W ••• �1,:' • �,� <br />U) <br />rn <br />TYPICAL REINFORCING Z �'1.#ONA�- � <br />BARS AT THICKENED U) <br />FOOTING, SEE PLAN O 03-19-2021 <br />MIN 24" LONG #4 OR #5 W <br />BAR SET AT MID -DEPTH <br />U REVISIONS: w <br />OF SLAB, TYP ALL = <br />RE-ENTRANT CORNERS (- <br />Q No. Description Date W <br />� --- ------ U <br />I <br />HOUSE SLAB 0 O <br />- <br />- - O Z <br />RE-ENTRANT CORNER DETAIL U y O <br />(RECOMMENDED) � <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS X f;T=2D <br />W <br />a- <br />Q <br />rMIIIMPTAI rONNPrTOR FNrINFFRINC; <br />