Laserfiche WebLink
BACKER ROD <br />I I <br />1 I <br />I I <br />BACKER ROD -- 1 <br />-INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SECILIE V_R OF FLASHMG TO BE: <br />L BOTTOM. 2_ SIDES. 3. TOP <br />-VENT CAP 18 TO BE SET M BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />-E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />-APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES, Yi CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R 03.7 <br />Exterior WJM and plaWAft <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-18b. <br />Installation of exterior lathing and framing <br />shall compy with ASTM C 1063-19a, <br />or ASTM 1787. <br />WRB LAYER -1, <br />STUCCO WRAP <br />11-:.-- <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER VENT (FRAME) <br />WOOD SHEATHING <br />WRB LAYER 9, <br />STUCCO WRAP <br />UI B LAYER 91, FORTIFIBER <br />BUILDING PAPER <br />WOOD — <br />CONSTUCTION <br />—METAL LATH <br />w CrU VINYL CASING BEAD <br />6' RAISED BAND <br />K' TO K' MMIID-WALL <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />Z FLASHING <br />ATCNE VENEER <br />OVER SCRATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK( <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — ------- <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 71/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-103.1.1 / ASTM C-84-1-14a, MIN. 2.5 LBS. <br />PER 60. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />0 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPE <br />UNDER 'QUICK FLASI <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDINCs PAPER <br />9' THICK, 3 COAT CEMENT <br />PLASTER <br />7b' TO Ya' MID -WALL <br />WEEP SCREED <br />6' SELF-ADHESIVE <br />FLASHING <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />(FRAME TO FRAME) <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WR8 LAYER'(, <br />STUCCO WRAP <br />WOOD SHEATHING <br />ELEC. METER FIELD APPROVED <br />VERIFY LOCATION HOUSEWRAP <br />BELOW <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT CUT SUCH THAT <br />B PRIOR TO INSTALLIWG ELEC. ENTERS BOX, <br />METER APPLY TO FACE <br />EDGE <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:;O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />APPLY E-Z BEAD <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />e <br />STEF #5 <br />WOOD SHEATHING <br />WQB LAYER -1. <br />STUCCO WRAP <br />WRB LAYER 4, FORTPIBER <br />BUILDMYPAPER <br />METAL LATH <br />-1/S' TEXrURED <br />FINISH • WOOD <br />-FASTEN TO WOOD STRUCTURAL <br />MEMBER • T OL. MAX <br />Y6. TO Yt' MID-IWLL <br />WEEP AGREED <br />APPLY 60 MIN <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APRDVED <br />HOUSEWRAP <br />El hMEM5RANE FLASHING <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />STEP *14 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />STEP #5 STEP #(o <br />OELECTRICAL RECEPTACLE <br />LATH MA <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />w abdesigngroup.com <br />AA 8: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SUITE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 91341186.2628 <br />FAX: 813-886-2802 <br />SUBDIV Z LOT: <br />SILVERADO <br />LOT# 11 <br />BLK# 16 <br />PROJECT#r <br />03719.000-11162 <br />s¢oaEr: <br />2795-CAMDEN" <br />GARAGE SVMG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />%150 MPH EXP. B <br />DATE 05/13/21 <br />SCALE: 1/4"=1'-O" <br />SHEET <br />WA2 <br />