7923 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7923 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 8:44:45 PM
Creation date
2/24/2025 9:26:45 AM
Metadata
Fields
Template:
Building Plans
Street #
7923
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■ <br />HVAC NOTES <br />MECHANICAL PLAN <br />SCALE: 1/4 . 1'-0• <br />I. ALL MECHANICAL EQUIPMENT SHALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SMALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 1TH EDITION (2020) MECHANICAL BLDC, CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL BI CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL. BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 1TH EDITION (2020) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 1TH EDITION <br />(2020) MECHANICAL CODE 603U <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 1TH EDITION (2020) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />S. ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS 814ALL BE INSTALLED TO MFG. RECOM!"ENDATIONS AND FBC 1TH <br />EDITION (2020) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />IL DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />AIR SUPPLY I:ll y <br />y <br />AIR <br />EVAR TRAY <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE. SUPPLY TRWK <br />— <br />BROKEN LINE. RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />EXTERIOR WALL <br />AIR RETURN SECUUW RE 3/161>01 TO CONC CONDENSER <br />WIT OR EQUAL <br />W3 ROLL STRAP <br />RUCTION AND LIQUID OR EQUAL <br />REFRIGERANT LINES <br />SECURE STRAP TO WIT W/ (2) <br />EXTERIOR WALL <br />4' CONCRETE SLAB <br />-SXI 1/4' $HT. MTL. SCREWS <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER <br />UNIT <br />y <br />;Tull <br />PVC SLEEVE TO LINES BELOW SLAB <br />REFRIGERANT LINES TO <br />CONNECTION <br />TO PAD <br />CONDENSING WIT <br />NOTE: MAIN COND.12'DRAM 3/4' <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD @' FROM STRUCTURE <br />TUR <br />IN AN APROVED DRAIN, AS PER <br />FBCR 1TH EDITION (2020) <br />MECHANICAL BLDG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />COUNTERSUNK <br />SCORIATED NICKEL <br />FIN. FLOOR <br />C.O. PLUG <br />BRONZE FL. PL. <br />OR WALL <br />I'-6' <br />SEE SPEC. <br />0 <br />I'-8'XaCONC. <br />BRASS PLUG <br />FIN. GRADE <br />OR PAVING <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />FITTING OR <br />REQUIRED <br />EXTENSION TO SOIL <br />OR WASTE AS <br />WADE 8240-K JOSAM 56000 <br />REQUIRED <br />INSIDE <br />SERIES NICKEL BRASS TOP <br />CAULK <br />P.V.0 OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYPN) NEXT. GROUND CLEAN -OUT (TYPN ) <br />1441 N. RONALD REAGAN BLVD. <br />ORLANDO, FL 32750 <br />PH: 407-774-6078 <br />FAX 407-774-4078 <br />w .abdesigngroupxom <br />AA G: 0003325 <br />DRAFTING BY: <br />A.B. DESIGN GROUP <br />DRAFTING INC. <br />5439 BEAUMONT CENTER BLVD. <br />SURE 1004 <br />TAMPA, FLORIDA 33634 <br />PH: 813886.2628 <br />FAX: 813.88E-2802 <br />SVHDIN de LOT, <br />: <br />SILVERADO <br />LOT# 11 <br />BLK# 16 <br />PROJECT# <br />7 - 2 <br />*ODEL- <br />2795-CAMDEN" <br />GARAGE 81rWO: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />150 XPH E B <br />