My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7929 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7929 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:22:39 PM
Creation date
2/24/2025 9:37:53 AM
Metadata
Fields
Template:
Building Plans
Street #
7929
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
319
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SMALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED A$ PER MC 6TH EDITION (2011) MECHANICAL. BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL ISI CLASS I AIR DUCT AS PER NFPA WA 2.3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SELLER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO MC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATWMG FIXTURES SHALL 15E <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO E=AL AIR EXHAUSTED. <br />t ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTECH DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />NOTE: <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />O O <br />EXTERIOR WALL <br />PLENUM <br />? y <br />AIR RETURN <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />y <br />AIR HANDLER <br />IOR WALL <br />yVC <br />CONDENSATE DRAIN LINE <br />EVAP. TRAY <br />yLEEVE <br />TO LINES BELOW SLAB <br />L314' <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURNCONDENSING <br />UNIT <br />TRAP DRAM LINE AND TERMINATE <br />IN AN APROVED DRAM, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL SLOG. CODE <br />SECTION 3013.4 <br />HVAC <br />DRAINS <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR 000 <br />(� <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />19 <br />PASS-THRU AIR GILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3/I6'X2' TAPCONS UNIT SIMF44N WB ROLL STRAP <br />OR EQUAL <br />4' CONCRETE SEAS SECURE STRAP TO UNIT W/ 0) <br />sSXI 1/4' SHT. MTL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 121 FROM STRUCTURE <br />SCORATED NICKEL FIN. FLOOR COUNTERSANK <br />BRONZE FL. PL. OR WALL CA. PLUG <br />BRASS PLUG <br />�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTIMPEC <br />(D LOOR SLAB CLEAN -OUT (TYPE <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-S'XS' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />DEXT. GROUND CLEAN -OUT (TYPJ. <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE FPS. ELEVATION. <br />MECHANICAL PLAN <br />SCALE, 1/4 " I'-0' <br />FNI <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32780 <br />PN: 407-774-6078 <br />FAX 407-7744078 <br />www.abdesigngroup.com <br />AAA: 0003325 <br />atMDlV S. LOT <br />ABBOTT PARK <br />LOT #13 <br />BLK #7 <br />PROJECT <br />04181,006-13071 <br />MODEZs <br />4EAB <br />"1672- ARIA" <br />GARAGE S71ING: <br />RIGHT <br />PAGE: <br />MECHANICAL <br />PLAN <br />%160 MPH XP. C <br />.J3I1 /II 21, <br />8CA X: 1/4"=1'-0" j <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.