My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7938 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7938 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 9:50:47 PM
Creation date
2/24/2025 10:10:26 AM
Metadata
Fields
Template:
Building Plans
Street #
7938
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
949
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TAD BE, <br />L BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO DE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER ARMY FROM JOINTS. <br />E-Z DEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIIIDDDES, Y4 CAULKING • JOINT <br />ALL ARO <br />PER SECTION R70.9.7 <br />Exhrlor I MbV and Watwing <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER 01, <br />STUCCO WARAP <br />I .: <br />HOODED VENT <br />x. <br />THICK 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER R, FORTIFIBER <br />BUILDING PAPER <br />WOOD "ATFIINa <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER - • - - - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-0% MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />W SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />0 DRYER VENT (BLOCK) <br />BUILDING PAPEF <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />6' SELF ADHESI, <br />FLASHING (INSTA <br />PER MANP.SPE <br />BUILDING PAPEF <br />UNDER 'QUICK FI <br />EVENT PENETRATION <br />SCALE: N.T.B. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />OUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAQ <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVI <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />STEP #1 <br />STEP #3 <br />WOOD 814EATWM <br />UM LAYER -1, <br />STUCCO WNtAP <br />WRS LAYER 7, FORTIFIDER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRIGTUR4L <br />MB-bEIR • T' O.C. MAX <br />K' TO )P MID -WALL <br />uNEEP nCNRlD <br />W WDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASCMIY Bill APPLYING <br />V FINISH • MASONRY <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />WRB LAYER h, <br />STUCCO WRAP <br />S' <br />STEP #2 <br />APPLY 60 <br />GRADE 'D' IFE FELT <br />OVER <br />SELF -ADHERING 0 <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP .. <br />WRB LAYER 01, <br />STUCCO WRAP <br />MEMBRANE FLASHING I <br />WM LAYER 02, FORTIF15ER <br />t3UILDMG PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP #5 STEP #(o <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 327l50 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdosigngroup.com <br />AA N: 0003325 <br />Q <br />R <br />r <br />ikk�j <br />G1 <br />G! <br />6 <br />� <br />Nb <br />a <br />�j <br />. <br />. <br />. <br />. <br />. <br />fA <br />W <br />1E <br />eUDDrv. & LOT: <br />ABBOTT PARK <br />LOT #15 <br />BLK #8 <br />PROJECT# <br />04181.000-15081 <br />MODSra <br />4EBB <br />"1828-CALI" <br />FlAnAGS aWrNC1: <br />RIGHT <br />PADS: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />
The URL can be used to link to this page
Your browser does not support the video tag.