My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7963 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
7963 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 11:35:13 PM
Creation date
2/24/2025 9:23:06 AM
Metadata
Fields
Template:
Building Plans
Street #
7963
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
22573
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT 614ALL. DE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS.. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL DE CONSTRICTED CF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAD 4 MASTIC, AND <br />INSTALLED AS PER MC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 101 CLASS 1 AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SMALL NOT BE LOCATED CLOSER THAN 10 FT. PROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SMALL DE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRICTED N ACCORDANCE TO FBC 6TH EDITION <br />(20rl) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED N ACCORDANCE WITH MC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SMALL HAVE AN APPROVED FIRE OR FIRE/EIMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL DE INSTALLED TO MFG. RECOMMENDATIONS AND P15C 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE FRONDED WITH BALANCING DAMPERS. <br />II. DRYER BOOSTER TO BE A FANTEC 4 DBF BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AlR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LM - RETURN TRUNK <br />1 <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />O <br />THERMOSTAT <br />m <br />PA66-THEM AIR GRILL <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONK. <br />ATTIC <br />W/ (2)-3/kr'X2' TAPCON6IDAIIR <br />SW'1P60N LLB ROLL STRAP <br />OR EQUAL <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />PLENUM <br />T <br />y <br />AIR RETURN <br />SECURE STRAP TO UNIT W/ (2) <br />4' CONCRETE SLAB bXI 1/4' SHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER UNIT <br />AIR HANDLER <br />y <br />CONNECTION TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAM LINE <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAD <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAM LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE FL. PL. OR WALL C.O. PLUG <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />601L OR WASTE AS <br />REQUIRED <br />INSIDE SEMES NICKEL BRASS TOP <br />CAULK P.VC OPTI/SPEC <br />FLOOR SLAB CLEAN -OUT (TYP) <br />FIN. GRADE <br />OR PAVING <br />SEE 6PEC. <br />I'-e'X6' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />ZEXT. GROUND CLEAN -OUT (TYP <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION. <br />MECHANICAL PLAN <br />.GALE, 1/4 . P-0' <br />]441 N. RONALD REAOAN BLVD. <br />LONGWOOD, FL 32750 <br />PH:407-774-6078 <br />FAX:407-774.4078 <br />www.abdes000up.com <br />AA M 0003325 <br />all <br />i <br />c <br />gg <br />aysnly rk Low <br />ABBOTT PARK <br />LOT #10 <br />BLK. #7 <br />0 4 arcs - 7 <br />HGDZIA <br />4EBB <br />"1828—CALI" <br />GARAOR swnro: <br />LEFT <br />PAGM <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />Tg <br />D TM 12/08/18 <br />WCALM 1/4-=1'-0- <br />81112= <br />M1 <br />