Laserfiche WebLink
INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />TO <br />SEQUENCE OF FLASHING BE: <br />1. BOTTOM, 2. SIDES, 3. TOP <br />�.:.X. <br />VENT CAPIS TO BE SET IN BED <br />I. <br />.�. . OF SEALANT AT TOP AND <br />`'.., <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />i <br />WATER AWAY FROM JOINTS. <br />�X <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />i i <br />X JOINTS AND INTERSECTIONS <br />i i <br />l APPLY SEALANT PERIMETER OF <br />BACKER ROD <br />! <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDES,)4' CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />Exterior lathing and plastering <br />BACKER ROD <br />I I <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />X.. <br />requirements of ASTM C 926-12A. <br />,I <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER 9, <br />STUCCO WRAP <br />iI <br />X <br />HOODED VENT <br />X' <br />}P'LTAHgGG R3 COAT CEMENT <br />METAL LATH <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />n DRYER <br />VENT (FRAME.) <br />DRAINAGE PLANE (UJRB <br />LAYER *I, STUCCO WRAP) <br />WRB LAYER *2 (FORTIFIBER — — — — — <br />BUILDING PAFER) <br />METAL LATH x—x-x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING — — — — NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-103.1.1 / 45TM C-847-09, MIN. 2.5 LBS, <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP + SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK _ _ _ <br />FLASH' I— 7 <br />PIPE THROUGH / <br />WALL k\` <br />I <br />6' SELF ADHESIVE <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.TS. <br />ELEC. METEF <br />VERIFY LO <br />iiRGN I V I�GI.rGI YG <br />STUCCO SCRATCH COAT <br />e 1 COAT OF PAINT W/BAOG- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />1 <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />-('GREAT STUFF" OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />I I THAT ELEC. WIRE PENETRATES <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEI TRAP <br />FOR BOX INSTALLATION <br />WRB LAYER h, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAI <br />EDGE <br />APPLY E-Z BEAI <br />OVER 60 MIN <br />GRADE 'D' <br />FELT -PROVIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />WRB LAYER -1, <br />STUCCO WRAP <br />WRB LAYER •2, FORTIF15ER <br />BUILDING PAPER <br />METAL LATH <br />WOOD 1/8, TEXTURED <br />CONSTRUCTION t f -FNISH a WOOD <br />FASTEN TO WOOD STRUCTURAL <br />MEMBER • T' O.G. MAX <br />S' Cm <br />Ys' TO K' MID -WALL <br />VEEP SCREED <br />FJ <br />• 6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />V PIN15H • MA60NRT <br />7B HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK <br />WRB LAYER "I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />•I <br />STEP #1 <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />S' <br />STEP #2 <br />WRB LAYER "l, <br />STUCCO WRAP <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />WRB LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />STEP *-4 <br />4tiELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STET= #5 STEW #(o <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD, FL 32750 <br />PH: 407.774.6078 <br />FAX: 407-774.4078 <br />www.abdesigngroup.00m <br />AA W: 0003325 <br />m <br />y <br />• <br />S <br />a <br />J <br />V <br />y <br />U <br />0 <br />� <br />e <br />Y <br />p <br />'U <br />FA <br />QQ <br />bt <br />m <br />C <br />�y <br />® <br />0 <br />6 <br />� U <br />h <br />stmDIV. & LOT: <br />ABBOTT <br />PARK <br />LOT #10 <br />BLK #8 <br />PROJECT# <br />04181.000-10081 <br />MODEL: <br />4EBB <br />"1828—CALI" <br />5ARAl3E 9WI7VCi: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />V. 160 A EXP. C <br />4 <br />DwTE: 04/29/20 <br />iSCALE: 1 /4"=1'- 0" <br />SKEET <br />Vd A2 <br />