My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
7976 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7976 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:07:33 AM
Creation date
2/24/2025 10:15:35 AM
Metadata
Fields
Template:
Building Plans
Street #
7976
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
1884
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
]ocuSign Envelope ID: 8B4D9CDD-19B3-4FOE-B3A9-573814FO9B29 <br />4O <br />O <br />N >; <br />a: <br />r- O <br />IliN APEX 1- <br />co <br />CD U, <br />O N <br />N tl� <br />N <br />M <br />J <br />LI_ <br />Ld <br />J <br />Jtds Z -0 <br />O true design studios <br />Y <br />U <br />9000 REGENCY SQUARE BLVD. 0 <br />o SUITE 100, JACKSONVILLE, FL 32211 c', <br />O cry <br />TMI <br />a <br />w <br />CA <br />0#ft*H0ff0N* <br />\ ELECTRIC METER 1 / F ELDTVERIFY LOCATION w / \\ FIELD a <br />LOCATION <br />-_ Q <br />APPLY STUCCO SCRATCH COAT AND ONE } <br />PRE -FORMED CONTROL 1) <br />� 5/8" CEMENT PLASTER ( � �•r• <br />JOINT W/ STRIP LATH _ _ LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC a �. <br />12" WIDE SELF-ADHESIVE METER U) <br />> <br />r <br />FLASHING CENTERED UNDER - <br />- a CONTROL JOINT (CLEAN CAVITY TO BE FILLED U <br />• +. : +:-•-= - ' � <br />MASONRY BEFORE APPLYING) - WITH RIGID POLYMERIC W <br />\ - ISOCYANOTE-POLYBLEN <br />FOAM ("GREAT STUFF" OR w <br />\ SIMILAR) <br />APPLY A SILICON BASE O <br />STUCCO FINISH SEALANT AT POINT THAT O <br />`7_ ----.- ELEC WIRE PENETRATES ti <br />5/8" CEMENT PLASTER / <br />6" SELF ADHESIVE <br />12" WIDE SELF-ADHESIVE / r OVER TOP &SIDES <br />FLASHING CENTERED UNDER / --- - - -- - ~ <br />CONTROL JOINT (CLEAN / \ SELF FLASHING • O <br />MASONRY BEFORE APPLYING) / \ UNIT Z <br />' -- -- --- ---- - - --T - PROVIDE STUCCO U) <br />PRE FORMED CONTROL - - _ " - -- ER <br />JOINT W/ STRIP LATH - �" • ' ' ' - - - •-� i•�•' - .= SCRATCH COAT LARGER <br />- THAN THE ELECTRIC Z W <br />PREMANUF. METER CAN OR METER <br />\ DRYER VENT CAP <br />/ - - (SET IN CONT. - - CAN COMBO OR METER <br />8" CMU {�,. - SEALANT) AREA TO RECEIVE CAN AND DISCONNECT m <br />t STUCCO SCRATCH COAT 1 1 1 <br />SEALANT at Uj <br />& 1 COAT OF PAINT W/ W <br />TOP & SIDES BACK -ROLL PRIOR TO Z <br />ELECTRIC METER _ <br />INSTALLATION (� C <br />Z G <br />w 0 <br />Q <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION 0 <br />SCALE: N.T.S. 0 w <br />SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. nLL w/ <br />O L.I. <br />-- <br />w <br />WOOD CONST BEYOND <br />FIBERCEMENT -OR- VINYL LAP 0 <br />WOOD SHEATHING' SIDING OVER APPROVED <br />6" SELF -ADHERING WEATHER RESISTIVE; HOUSEWRAP INSTALLED PER O <br />FLASHING BARRIER #1 FINISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS U x <br />��I• THREE COAT STUCCO FINISH EXTEND HOUSEWRAP <br />WEATHER RESISTIVE WEATHER RESISTIVE (ia' NOM) OVER GALV MTL LATH Q <br />OVER NAILING FLANGE `- <br />WD SHEATHING f OVER 15# FELT OVER APPROVED Z <br />BARRIER #1 BARRIER #2 !'' HOUSEWRAP WD SHEATHING VINYL ANGLED a \ (RE: STRUCT) <br />CASING BEAD WEATHER RESISTIVE �\ \ O <br />(AM66-ANGLED-1250) BARRIER #2 \ 5/16" X 7 1/4" LAP FASTEN TO WO STRUCTURAL (RE: STRUCT) __ <br />`- W <br />\ SIDING W/6 REVEAL MEMBER 7"AX f- <br />BE at O.C.O C - MTL DRIP FLASHING W/ Q Z <br />STARTER STRIP / " TO § " MID -WALL _ HEMMED EDGE SET IN CONT <br />2 1/2" ' c �s e BEAD OF SEALANT 0 <br />WEEP SCREED a <br />8" CMU CORNER BEAD / I DO NOT CAULK OR '? - - TRIM (RE: ELEVATION) _ <br />(FASTENER & 6" SELF -ADHERING -- r �': SEAL OPENING - _ _ Z d - Z <br />U' = SPACING at 7"O.C. FLASHING N - Q <br />o z - -- - ) EXTEND 12" SELF -ADHERING LLJ <br />GALV D METAL MEMBRANE FLASHING OVER <br />—a GALV'D METAL "Z" - WINDOW FLANGE SET IN CONT Q <br />~ N "Z" FLASHING <br />(A FLASHING 6" WIDE STRIP SELF ADHESIVE BEAD OF SEALANT 0 U <br />W w w w FLASHING, CLEAN MASONRY Z U) <br />> _ - DO NOT CAULK OR / - - - - 1 1/4" X 6" SIMULATED - - `• BEFORE APPLYING VINYL FLANGE CASING BEAD = PROJECT NO: 0 <br />SEAL OPENING _ _ `.:` WOOD TRIM MEMBER _ --- - - INSTALLED PER MFR W <br />1/2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) W Q <br />CMU STUCCO TEXTURED PER COMMUNITY �- <br />1 1/4" X6" SIMULATED •+'•:: .. �.. 1/2" (MIN) STUCCO FINISH <br />CASING BEAD SPECIFCATIONS W DRAWN: <br />VINYL CASING WOOD TRIM MEMBER TEXTURED PER COMMUNITY <br />BEAD (AM66-1250) !`� SPECIFCATIONS Q DVO W <br />1/2" (MIN) STUCCO FINISH <br />1/2" MIN TEXTURED --- TEXTURED PER COMMUNITY <br />(MIN) SPECIFCATIONS SEAL GAP W/ CAULKING CHKD: TSD <br />FINISH at MASONRY OR APPROVED SEALANT /' LL. <br />STUCCO CASING BEAD ` STUCCO SIDING O <br />m <br />O <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION (FRAME TO BLOCK) Z LO <br />U) <br />SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. z w <br />SCALE: N.T.S. 0 < <br />w U <br /><C cn <br />Z 0 <br />U) Z <br />0 <br />CMU WALL Wl SELF ADHESIVE -OR- FLUID CMU WALL W/ ~ <br />1/2" (MIN) STUCCO APPLIED PAN FLASHING (CLEAN FINISH TEXTURED �8' STUCCO FINISH CMU LINTEL 1/2" (MIN) STUCCO FINISH U , <br />MASONRY BEFORE APPLYING) (RE: STRUCTURAL) <br />PER COMMUNITY EXTEND UP AT JAMBS (4" MIN) k�" GYP BRD OVER k�" GYP BRD OVER E. STRUCTURAL) (RE' STRUCTURAL) (R L) <br />ILL <br />SPECIFCATIONS Y " GYP BRD OVER GYP BIRD OVER U' <br />z PRE -SHAPED STUCCO BAND.. PRE -SHAPED STUCCO BAND 1x2 TREATED 1x2 TREATED Q <br />1x2 TREATED W/ SLID TOP INSTALLED PER 1x2 TREATED W/ INSTALLED PER MFR FURRING STRIPS FURRING STRIPS j (n Z <br />FURRING STRIPS MFR WRITTEN SPECS (RE: FURRING STRIPS WRITTEN SPECS (RE: ELEV) CONTINUOUS BEAD CONTINUOUS BEAD - <br />FLANGE CASING <br />at CMU WALL (TYP) ELEV) at CMU WALL (TYP) PRECAST CONCRETE SILL at CMU WALL (TYP) OF SEALANT at CMU WALL (TYP) OF SEALANT >- REVISIONS: <br />BEAD SELF ADHESIVE -OR- FLUID WOOD BLOCKIN SELF ADHESIVE -OR- FLUID " BACKER ROD W/ SEALANT PT 1x4 0 <br />APPLIED FLASHING (CLEAN APPLIED FLASHING (CLEAN a PT 1x4 SELF ADHESIVE -OR- M SELF ADHESIVE -OR- O N Description Date o <br />o. <br />MASONRY BEFORE APPLYING) VINYL FLANGE CASING BEAD FLUID APPLIED E FLUID APPLIED <br />MASONRY BEFORE APPLYING) PT 2x4 FRAME J <br />GYP BIRD OVER INSTALLED PER MFR PT 2x4 FRAME ANCHOR FLASHING (CLEAN ANCHOR FLASHING (CLEAN <br />PT 1x WOOD BUCK PT 1x WOOD BUCK (n <br />VINYL FLANGE CASING BEAD VINYL FLANGE CASING BEAD _._ _ _.__ <br />- 1x2 TREATED WRITTEN SPECS (TYP) SHIM AS NEEDED MASONRY BEFORE MASONRY BEFORE Z W <br />- _ SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR qq���pp��yy NG, SHIM AS NEEDED gpp�Y NG� <br />FURRING STRIPS METALI DOOR FRAME METALI DOOR FRAME U -- <br />WRITTEN SPECS (TYP) <br />WRITTEN SPECS (TYP) CMU STUCCO <br />FINISH <br />LL W/ <br />at CMU WALL (TYP <br />) � • �' � 48" STUCCO FINISH w <br />48" BACKER ROD W/ SEALANT BACKER ROD W/ SEALANT (RE: STRUCTURAL) INTERIOR EXTERIOR INTERIOR EXTERIOR ~ - - - w <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR X <br />W U <br />CASING BEAD at WN WINDOW HEAD at CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CMU Q o <br />SCALE: N.T.S. SCALE: 1 1/2" = 1'-0" SCALE: 1 ti2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 ti2" = 1'-0" SCALE: 1 1/2" = 1'-0" Z <br />A501 O <br />�o, <br />
The URL can be used to link to this page
Your browser does not support the video tag.