7979 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
7979 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 12:12:17 AM
Creation date
2/24/2025 10:10:43 AM
Metadata
Fields
Template:
Building Plans
Street #
7979
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
952
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT ALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATMG. ALL SEAMS SHALL BE SEALED WITH GLASS PAIS 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLOG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 101 CLASS I AIR DUCT A8 PER NPPA 10A 2-31 <br />4. FRESH AIR INTAKE& GALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER MC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORM8 SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6114 EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR 15ATHNG FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH MC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />9. ALL FIRE RATED CEILINGS AND WALLS SHALL. HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10, GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTEC 4 DRIP BOOSTER FAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />1 <br />BALANCING DAMPER OR ODD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN a LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />IS <br />PASS-THRU AIR GRILL <br />NOTE, <br />ALL NVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O <br />O <br />EXTERIOR WALL <br />TRAP TAF�B <br />COND_\ ENSER <br />PLENUM <br />PLENUM <br />y <br />AIR RETURN <br />W/G(�3A6'x2' <br />6IMP80N WO ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />AIR HANDLER <br />y <br />TL. SCREWS (2) <br />4' CONCRETE BLAB PCOI UI//4' STRAP <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER UNIT <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />CONNECTION TO PAD <br />t <br />REFRKsERANTLNESTO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD a 12' FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLDG. CODE <br />SECTION 3012.4 <br />HVAC <br />DRAINS <br />COU <br />SCORIATED NICKEL <br />FIN. FLOOR <br />G.ERSUNK <br />O . PLUG <br />BRONZE FL. PL. <br />OR WALL <br />I _6 <br />SEE SPEC. <br />CONc. <br />BRASS PLUG <br />FIN. GRADE <br />OR PAVING <br />FITTING OR EXTEN6ION TO <br />SOIL OR WASTE AS <br />FITTING OR <br />REQUIRED <br />EXTENSION SOIL <br />OR WASTE AS <br />rWADE 8240-K JOSAM 56000 <br />REQUIRED <br />INSIDE <br />/ SERIES NICKEL BRA88 TOP <br />CAULK <br />/ P.V.0 OPTI/SPEC <br />nFLOOR SLAB CLEAN -OUT (TYY nEXT. GROUND CLEAN -OUT (TYP <br />■ <br />HVAC PLAN <br />E= 1/4 . P-0' <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdosigngroup.com <br />AA B: 0003325 <br />t <br />O <br />, <br />AN <br />fvBDV aIT <br />ABBOTT PARKA <br />LOT #9 <br />BLK #15 <br />PROJECT* <br />04181.000-09151 <br />HODEEa <br />4EAB <br />"1672- ARIA" <br />GARAGE 3WING: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />