My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8004 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8004 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 1:26:25 AM
Creation date
2/24/2025 10:13:00 AM
Metadata
Fields
Template:
Building Plans
Street #
8004
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
402
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />SACKER ROD <br />WRB LAYER h, <br />ATurrri uiRAP <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHNCs OVER <br />TOP. SIDE(W AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE E)0HAUST. <br />SgCILIENCE OF FLAS 4NG TO SE, <br />I. SOTTQM. 2. BIDLB. 3. TOP <br />VENT CAP 18 TO BE SET N BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 18 TO BE <br />TOOLED 60 A8 TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE& X CAULKING a JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />E:derlor latltktp and pla2erkto <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />I'• HOODED VENT <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER R, FORTIFIBER <br />BUILDING PAPER <br />WOOD 814EATHM <br />DRYER VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER — — — — — <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING — — — — — <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-541-09, MIN. 2.5 LBS. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />WOOD SFEATNNG <br />FLASHING <br />LAYER q, <br />UNIT <br />STUCCO WRAP <br />LAYER 02, FORTIFIBER <br />PREMANUF. DRYER <br />BUILDING PAPER <br />VENT CAP (SET IN <br />METAL LATH <br />CONT. SEALANT) <br />WOOD <br />-INMIGM <br />CONSTRUCTION <br />f * WO DD <br />FA&M TO WOOD STRNCTURAL <br />SEALANT <br />MEMDER • 1' O.C. MAX <br />TOP 4 SIDES <br />° cru <br />w' TON tgl7-WALL <br />WEEe �r�n <br />6B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROIYsH <br />WALL <br />1 <br />6' SELF ADHESIVE - <br />FLASHING (INSTALL <br />PER MANUR SPECS.) <br />BUILDING PAPER — <br />LINDER 'QUICK FLASH' <br />ELEC. METEF <br />VERIFY LO <br />---7 <br />%VENT PENETRATION <br />SCALE, N.T.S. <br />G7r IV FGVGIYL <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/ 3ACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYSLEND FOAM <br />('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER $1, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />CUT SUCH TWA <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FAA <br />EDGE <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVI. <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />m S <br />6' WIDE STRIP SELF <br />ADHESIVE FLASHING, CLEAN <br />MASONRY 0EPOW APPLYING, <br />L- FINISH • MASONRY <br />(�oHORIZONTAL WEEP SCREED <br />(FRAME TO BLOCKZ <br />B' <br />WRB LAYER 41, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRS LAYER <br />M <br />STEP #1 <br />STEP #2 <br />t� <br />WIRS LAYER 01, <br />I <br />STUCCO WRAP <br />STUCCO <br />APPLY 60 MIN - <br />CRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOIISEWRAP <br />STEP #3 <br />® [ MEMBRANE FLASHING <br />�- WRB LAYER'4, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />JUN 1 <br />STEP 05 STEP #6 <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD RFAGAN BLVD <br />LONGWOOD,FL32750 <br />PH: 407-7748078 <br />FAX- 407-774-4078 <br />www.abdealgngroup.com <br />AA #: 0003328 <br />as <br />IR <br />u <br />jig <br />O <br />40 <br />w <br />x <br />0 <br />x <br />it <br />DdSVBTABPAL <br />ORTK <br />LOT 78 <br />BLK <br />PROJECT# <br />04181.000-07 81 <br />MODEL: <br />4EBB <br />"1828—CALI" <br />GARAGE 9WINCi: <br />RIGHT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />