My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8015 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
8015 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:04:37 AM
Creation date
2/24/2025 9:35:57 AM
Metadata
Fields
Template:
Building Plans
Street #
8015
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
22255
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT WALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING, ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL BLDG. CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA WA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHA"NEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />5. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />I. BATHROOMS CONTAINING BATHTUBS, $HOLLERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH MC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />S. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />3 ALL FIRE RATED CEILINGS AND WALLS ¢yAL-L HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECCIMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS, <br />11. DRYER BOOSTER TO BE A PANTEC 4 OBF BOOSTER FAN OR EQUAL. <br />PANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />ATTIC <br />AIR BUPPLY-'� I�I U' <br />AIR HANDLER I y <br />EVAP. TRAY <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ERIOR WALL <br />RETURN <br />SUCTION AND LIQUID <br />REFRIGERANT LINES <br />EXTERIOR WALL <br />3/4' PVC CONDENSATE DRAIN LINE <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />IV <br />w�i <br />TRAP DRAIN LINE AND TERMINATE <br />�IN AN APROVED DRAIN, AS PER <br />POOR 6TH EDITION (2011) <br />MECHANICAL SLOG. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />BRASS PLUG <br />FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />//-- REQUIRED <br />NSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.0 OPTI/SPEC <br />OFLOOR SLAB CLEAN -OUT (T <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />SOLID LINE- SUPPLY TRUNK <br />BROKEN LANE" RETURN TRUNK <br />BALANCING DAMPER OR OBD <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />SECURE STRAP TO CONC. CONDENSER <br />W/ (2)-3A6'X2' TAPCONB UNIT $IMPSON WB ROLL STRAP <br />OR EQUAL �T <br />WALL <br />W CONCRETE SLAB SECURE STRAP TO UNIT W/ (2) <br />•8XI 1/4' BHT. MITL. SCREWS <br />CONDENSER UNIT <br />CONNECTION TO PAD <br />NOTE. MAN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />COUNTERSUNK <br />CA. PLUG <br />FIN. GRADE <br />OR PAVING <br />SEE SPEC. <br />I'-8'X6' CONC. <br />FITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />vEXT. GROUND CLEAN -OUT (TYPN ) <br />FIRST FLOOR <br />MECHANICAL PLAN <br />SCALE, 1/4 - P-0' <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdosigngroup.com <br />AA A 0003325 <br />1 <br />gill <br />O <br />I <br />F <br />MO <br />auHDm ac i oz: <br />ABBOTT PARK <br />LOT ##5 <br />BLK ##7 <br />P1FtoJEOTUjU <br />04181.000-05071 <br />MODEL: <br />3EEB <br />"2260-ELSTON" <br />GA1tAGE 9TrWG: <br />LEFT <br />PAGE: <br />FIRST FLOOR <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />DAATE` 09/12/19 <br />acALE: 1/4"=1'-0" <br />810nm <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.