My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8015 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
8015 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:04:37 AM
Creation date
2/24/2025 9:35:57 AM
Metadata
Fields
Template:
Building Plans
Street #
8015
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
22255
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />WRD LAYER 1, <br />gTur-r-ri ~ <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(8) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO BE, <br />I. BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP 16 TO BE SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 18 TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL SIDE&V CAULKING • JOINT <br />ALL AROUND <br />PER SECTION R703.7 <br />ExtwW IsNing snd plaaerin0 <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />HOODED VENT <br />THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRB LAYER O, FORTIRBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />WOOD SHEATHING <br />4M LAYER 1, <br />STUCCO WRAP <br />W IS LAYER'2, FORTIFIBER <br />WOOD — <br />CONSTUCTION <br />—METAL LATH <br />S' CMU VINYL CASING DEAD <br />6' RAISED BAND <br />7�' TOJi' MID -WALL <br />DEEP SCREED <br />W WIDE STRIP SELF <br />ADHESIVE FLAGWM. CLEAN <br />MASONRY DEFORE APPLYING <br />Z FLASHING <br />STONE VENEER <br />OVER 60RATCH COAT <br />HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK} <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER "I, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER - - . - . - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R703.7.1 / ASTM C-847-OS, MIN. 2B L155. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />6B DRYER VENT (BLOCK) <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIP15ER <br />BUILDING PAPER <br />}' THICK, 3 COAT CEMENT <br />PLASTER <br />V TO V MID -WALL <br />WEEP Ar_REED <br />�6' SELF-ADHESIVE <br />FLASHING <br />BUILDING PAPER OVER 'QUICK WOOD FRAMED <br />FLAS"' r — — — WALL <br />HORIZONTAL WEEP SCREED <br />PIPE <br />WALL T" " (FRAME TO FRAME <br />I <br />6' SELF ADHESIVE <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />BUILDING PAPER I / I UNDER 'QUICK FLASH' lti.. <br />VENT PENETRATION <br />SCALE+ N.T.S. <br />ELEC. METEF <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />I <br />I <br />ELEC. METER FIELD <br />�\ VERIFY LOCATION <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />">R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />:O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED NOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER 1, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSE~ <br />BELOW <br />CUT SUCH TWA' <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO PAC <br />EDGE <br />APPLY E-Z <br />OVER 6m MI <br />GRADE TP <br />FELT-PROVI <br />SEALANT Al <br />JOINTS AND <br />INTERSECTIC <br />STEP #1 <br />STEP #3 <br />WOOD <br />CONSTRUCTION <br />s' CMU <br />WOOD 814EATWMG <br />WRB LAYER 1, <br />STUCCO WRAP <br />WRB LAYER F2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STRICTU AL <br />MEMBER • T' OL. MAX <br />$' TON MID -WALL <br />WEEP SCR![D <br />W WIDE STRIP SELF <br />ADHESIVE FLASHING. CLEAN <br />MASONRY BEFORE APPLYING <br />V FMI8H • MASONRY <br />(7DB HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />WPM LAYER 1, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />k <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED WRB LAYER <br />1 <br />STEP <br />#2 <br />WRB LAYER 1, <br />4. <br />STUCCO WRAP <br />APPLY 60 MIN <br />SEE <br />GRADE 'D' FELT <br />® <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEURAP <br />WRB LAYER 92, FORTIFIBER <br />BUILDING PAPER <br />STEP <br />*14 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ C.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP #& <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #-. 0003326 <br />ISa <br />J <br />1 <br />4 <br />IAB <br />BOTT PARK <br />LOT #5 <br />BLK #7 <br />OJRCT* <br />04181.000-05071 <br />1RODEt1 <br />3EEB <br />"2260—ELSTON" <br />GARAGE SWING: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />D � 09/12/19 <br />SCALR: 1/4"=1'—O" <br />S**EMT <br />Vd A2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.