My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8023 Sail Clover Ln
Zephyrhills
>
Building Department
>
Building Plans
>
8023 Sail Clover Ln
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:25:09 AM
Creation date
2/24/2025 9:35:23 AM
Metadata
Fields
Template:
Building Plans
Street #
8023
Location
Sail Clover Ln
Contractor
D R Horton
Building Plans - Permit #
22102
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
E <br />0 0 <br />O y <br />U. <br />01 <br />PE^ <br />c <br />x <br />(I) <br />Ncf) m <br />N <br />,pol <br />J <br />z <br />U) <br />U <br />9000 REGENCY SQUARE BLVD. <br />o SUITE 100, JACKSONVILLE, FL 32211 c: <br />o 6 <br />W <br />H - <br />1 (/) a see o ago <br />flon4HOMN <br />/ \ ELECTRIC METER m <br />\� ELECTRIC METER J f - W <br />/ FIELD VERIFY LOCATION <br />FIELD VERIFY W' <br />LOCATION A <�` � S>'�=�.•,:°._> <br />PRE -FORMED CONTROL �_ APPLY STUCCO SCRATCH COAT AND ONE (1) <br />JOINT W/ STRIP LATH 5/8" CEMENT PLASTER \`\ \\` \ZZ <br />LAYER OF PAINT PRIOR TO INSTALLING ELECTRIC <br />12" WIDE SELF-ADHESIVE METER _ <br />FLASHING CENTERED UNDER • i- <br />r CONTROL JOINT (CLEAN - CAVITY TO BE FILLED U <br />��� MASONRY BEFORE APPLYING) WITH RIGID POLYMERIC W <br />I/ ISOCYANOTE-POLYBLEN <br />r FOAM ("GREAT STUFF" OR W <br />/ SIMILAR) <br />LA <br />STUCCO FINISH A SILICON BASE O \ SEALANT AT POINT THAT C <br />ELEC WIRE PENETRATES <br />: 5/8" CEMENT PLASTER / 6" SELF ADHESIVE <br />LO <br />12" WIDE SELF-ADHESIVE 1 \ OVER TOP & SIDES <br />FLASHING CENTERED UNDER / <br />I \ <br />CONTROL JOINT (CLEAN � \ SELF FLASHING O <br />MASONRY BEFORE APPLYING) / UNIT 'i - 1 <br />! PROVIDE STUCCO U) (� <br />1 PRE -FORMED CONTROL -- a -� : ---- SCRATCH COAT LARGER LU U) <br />a� JOINT VV/ STRIP LATH ___� -� THAN THE ELECTRIC z <br />\ / PREMANUF. METER CAN OR METER w <br />\ DRYER VENT CAP CAN COMBO OR METER <br />A _ AREA TO RECEIVE CAN AND DISCONNECT m <br />8" CMU , <br />_. � / SEALANTSET IN ONT. � <br />I ) STUCCO SCRATCH COAT � 1 1 I I <br />t SEALANT at w <br />& 1 COAT OF PAINT W/ LL! <br />TOP &SIDES BACK -ROLL PRIOR TO Z <br />ELECTRIC METER - <br />INSTALLATION z <br />W <br />Q <br />CONTROL JOINT - HORIZ - CMU CONTROL JOINT - VERTICAL - CMU DRYER VENT (BLOCK) ELECTRICAL CONDUIT PENETRATION <br />SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. SCALE: N.T.S. O <br />O <br />Q <br />WOOD CONST BEYOND <br />< 0 <br />FIBERCEMENT -OR- VINYL LAP O <br />WOOD SHEATHING' SIDING OVER APPROVED a <br />WEATHER RESISTIVE ;: �( HOUSEWRAP INSTALLED PER O ti <br />6" SELF -ADHERING { FINISH COATING OVER PRIMED MFR WRITTEN SPECIFICATIONS <br />FLASHING BARRIER #1 ± ,� O X <br />THREE COAT STUCCO FINISH EXTEND HOUSEWRAP <br />WEATHER RESISTIVE i WEATHER RESISTIVE } (r$' NOM) OVER GALV MTL LATH <br />BARRIER #1 BARRIER #2 WD SHEATHING OVER 15# FELT OVER APPROVED OVER NAILING FLANGE Z <br />VINYL ANGLED (RE: STRUCT) HOUSEWRAP WD SHEATHING O <br />CASING BEAD WEATHER RESISTIVE �\ (RE: STRUCT) I ® Q <br />(AM66 ANGLED-1250) <br />BARRIER #2 = \ 5/16" X 7 1/4" LAP <br />�:.'. FASTEN TO WD STRUCTURAL lL W <br />SIDING W/ 6 REVEAL MEMBER at 7" O.C. MAX I-� MTL DRIP FLASHING W/ Q <br />2 1/2" ' HEMMED EDGE SET IN CONT - z <br />STARTER STRIP 7, " TO §a" MID -WALL - <br />/ {; BEAD OF SEALANT O <br />CORNER BEAD / DO NOT CAULK OR :): WEEP SCREED z a <br />8" CMU TRIM (RE: ELEVATION) LL <br />• (FASTENER & 6" SELF -ADHERING a:. �' SEAL OPENING k``) z <br />- SPACING at 7"O.C.) FLASHING �- / t= I - ';i ;;i - Q - <br />o z - EXTEND 12" SELF -ADHERING W <br />N / �1;. .a�T' ® - :I MEMBRANE FLASHING OVER __ J <br />m Q GALV'D METAL -. a - GALV'D METAL ,Z, WINDOW FLANGE SET IN CONT J Q <br />� L - c� "Z' FLASHING ;; FLASHING - 6" WIDE STRIP SELF ADHESIVE - :1 BEAD OF SEALANT O U <br />W rr - w _ FLASHING, CLEAN MASONRY :::j z <br />> _ DO NOT CAULK OR 1 1/4" X 6" SIMULATED BEFORE APPLYING �:.� VINYL FLANGE CASING BEAD = PROJECT NO: <br />j SEAL OPENING T _ WOOD TRIM MEMBER INSTALLED PER MFR 0Lli <br />1/2" (MIN) STUCCO FINISH WRITTEN SPECS (TYP) W Q <br />STUCCO TEXTURED PER COMMUNITY I � <br />CMU 1 1/4" X 6" SIMULATED CASING BEAD SPECIFICATIONS ,::i 1/2" (MIN) STUCCO FINISH z <br />VINYL CASING WOOD TRIM MEMBER TEXTURED PER COMMUNITY W DRAWN DVO v <br />BEAD (AM66-1250) f ' I SPECIFCATIONS � (� <br />1/2" (MIN) STUCCO FINISH <br />TEXT1/2" (MIN) TEXTURED SPECIUC ATIONSED PER COMMUNITY SEAL GAP W/ CAULKING / X CHKD: Ta�D Q <br />FINISH at MASONRY - OR APPROVED SEALANT / ' I I Q �7 W <br />STUCCO CASING BEAD �/ STUCCO C C O SIDING } O <br />RAISED BAND at BLOCK CORNER BEAD at BLOCK SIDING TO STUCCO HORIZONTAL MATERIAL TRANSITION FRAME TO BLOCK � o <br />( ) z <br />SCALE: N.T.S. SCALE: N.T.S. FRAME TO BLOCK SCALE: N.T.S. J <br />SCALE: N.T.S. p Q <br />LLI U <br />Q c/) <br />z (D <br />cn Zri <br />CMU \HALL W/ SELF ADHESIVE OR FLUID I- <br />1/2 (MIN) STUCCO 1 APPLIED PAN FLASHING (CLEAN CMU WALL W/ <br />�8" STUCCO FINISH CMU LINTEL 1/2" MIN STUCCO FINISH <br />FINISH TEXTURED MASONRY BEFORE APPLYING) (MIN) U_ <br />(RE: STRUCTURAL) (RE: STRUCTURAL) (RE: STRUCTURAL) <br />PER COMMUNITY _ I. EXTEND UP AT JAMBS (4" MIN) <br />tiz PRE -SHAPED STUCCO BAND 1,,, , GYP BIRD OVER "GYP BIRD OVER - - - ILL U <br />SPECIFICATIONS �� GYP BIRD OVER GYP BIRD OVER I/ I PRE -SHAPED STUCCO BAND Z Ur <br />I, 1x2 TREATED 1x2 TREATED Q z <br />. ... ..:�-t 1x2 TREATED W/ SLIP TOP INSTALLED PER 1x2 TREATED W/ INSTALLED PER MFR FURRING STRIPS <br />FU <br />RRING STRIPS <br />FURRING STRIPS MFR WRITTEN SPECS (RE: FURRING STRIPS WRITTEN SPECS (RE: ELEV) - <br />at CMU WALL (TYP) t ELEV at CMU WALL (TYP) PRECAST CONCRETE SILL at CMU WALL (TYP) CONTINUOUS BEAD at CMU WALL (TYP) CONTINUOUS BEAD <br />FLANGE CASING l� ) OF SEALANT OF SEALANT > REVISIONS: <br />Q <br />BEAD SELF ADHESIVE OR FLUID SELF ADHESIVE -OR FLUID PT 1x4 Cri <br />APPLIED FLASHING CLEAN WOOD BLOCKINGAPPLIED FLASHING CLEAN 6. a$" BACKER ROD W/ SEALANT PT 1x4 <br />( ( SELF ADHESIVE -OR SELF ADHESIVE OR O NO. Descri tion Date o <br />I:: Q PT 2x4 FRAME J p <br />MASONRY BEFORE APPLYING) MASONRY BEFORE APPLYING) VINYL FLANGE CASING BEAD FLUID APPLIED FLUID APPLIED <br />PT 1x WOOD BUCK PT ix WOOD BUCK-- Z" GYP BIRD OVER ........ [:. PT 2x4 FRAME ANCHOR FLASHING (CLEAN FLASHING (CLEAN W <br />INSTALLED PER MFR ANCHOR I O <br />VINYL FLANGE CASING BEAD VINYL FLANGE CASING BEAD 1x2 TREATED I WRITTEN SPECS (TYP) SHIM AS NEEDED MASONRY BEFORE Z U <br />SHIM AS NEEDED INSTALLED PER MFR SHIM AS NEEDED INSTALLED PER MFR AAPPPPLLYY NGl SHIM AS NEEDED AAMppAppSLLOYYNNRGY�BEFORE LLI <br />WRITTEN SPECS (TYP) WRITTEN SPECS (TYP) FURRING STRIPS CMU STEMWALL W/ METALI DOOR FRAME METALI DOOR FRAME U - _ <br />at CMU WALL (TYP) <� <br />`?a" STUCCO FINISH W W <br />TV, I VIL, <br />q8" BACKER ROD W/ SEALANT �a" BACKER ROD W/ SEALANT (RE. STRUCTURAL) INTERIOR EXTERIOR INTERIOR EXTERIOR I- J <br />INTERIOR EXTERIOR INTERIOR EXTERIOR INTERIOR EXTERIOR XW Q <br />0- - U <br />CASING BEAD at WN WINDOW HEAD at CMU WINDOW JAMB at CMU WINDOW SILL at CMU DOOR HEAD at CMU DOOR JAMB at CU a o <br />M <br />SCALE: N.T.S. SCALE: 1 1/2" = 1'-0" SCALE- 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE: 1 1/2" = 1'-0" SCALE' 1 1/2" = 1'-0" z <br />A501 O <br />0 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.