My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8027 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8027 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:40:45 AM
Creation date
2/24/2025 10:12:16 AM
Metadata
Fields
Template:
Building Plans
Street #
8027
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
917
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F� : 4 8-- •r7 <br />BACKER ROD <br />INSTALL 6' SELF -ADHERING <br />MEMBRANE PLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEry jyH= OF FLASHING TO BE, <br />1. BOTTOM. 2. SIDES. 3. TOP <br />VENT CAP IS TO BE SET N BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT IS TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF <br />NCN-MOVABLE FRAME AND STUCCO <br />ON ALL SIDDESA' CAULKING • JOINT <br />ALL AROUN <br />PER SECTION R703.7 <br />Bdeft IS t*W and pWleflrlp <br />Exterior use of portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-12A. <br />WRB LAYER 9, <br />STUCCO wQAP <br />Hoa>eD VENT <br />3 COAT CEMENT <br />PLTWIIM <br />ASTER <br />METAL LATH <br />WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER "I, STUCCO WRAP) <br />WRB LAYER "2 (FORTIFIBER ------ <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD SHEATHING <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-0S, MIN. 2.5 L55. <br />PER 50. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT* <br />TOP 4 SIDES <br />9 DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />6' SELF ADHESIVE — <br />PLASHING (INSTALL <br />PER MANUP. SPECS.) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE, N.T.S. <br />ELEC. METER FIELD <br />VERIFY LOCATION <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CUT OPENING INI <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER @I, <br />STUCCO WRAP <br />WOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />ELEC. METER FIELD <br />BELOW <br />VERIFY LOCATION <br />GUT SUCH <br />AN <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY STUCCO SCRATCH COAT <br />APPLY TO FAf <br />EDGE <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />A SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />APPLY E-Z <br />OVER 6® MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />INTERSECTIC <br />WOOD SHEATHING <br />WRS LAYER 9, <br />STUCCO WRAP <br />WRB LAYER 4, FORTIPMER <br />BUILDING PAPER <br />METAL LATH <br />O WOOD STRUCTURAL <br />• V OL, MAX <br />KTO )�' MID.WdI_L <br />WEEP SCREED <br />ADHESIVE PLASHING, CLEAN <br />MASONRY BEFORE APPLYING <br />v FMISH • 19A8ONRT <br />(toHORIZONTAL WEEP SCREED <br />FRAME TO BLOCK <br />S' <br />WRB LAYER @I, <br />STUCCO WRAP <br />CUT 'X' INTO <br />SELF -ADHERING <br />x <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED URB LAYER <br />$I <br />STEP #1 <br />STEP #2 <br />LAYER 9, <br />STU <br />STUCCO WRAP <br />APPLY 'm MIN - <br />CaRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />STEP #3 <br />® (MEMBRANE FLASHING <br />�- WRB LAYER 4, FORTIFIBER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATM OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP #& <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD, <br />LONGWOOD, FL 32750 <br />PH: 407-774.6078 <br />FAX: 407-774.4078 <br />www.abdesigngroup.com <br />AA M: 0003325 J <br />Y <br />o <br />rT <br />$VBDIV ac LOT <br />ABBOTT PARK <br />LOT #5 <br />BLK #15 <br />PROJECT* <br />04181.000-05151 <br />MODEP <br />1408" <br />"DAKOTA" <br />GARAGE BMWO: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />Dw 08/13/20 <br />9CAL.E: 1/4"=1'— 0" <br />EiHEET <br />WA2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.