My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8034 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8034 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 2:57:01 AM
Creation date
2/24/2025 9:52:47 AM
Metadata
Fields
Template:
Building Plans
Street #
8034
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
22576
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MOTEI <br />APPROVED BULLDNG WRAP <br />PIEFOR'ED GONTROI. JOINT <br />RANGE Q CONTROI- JOINTS T <br />BE WIRED TIED TO LATH R 9' <br />O.C. MAX (VERT.1 W7_ DO <br />NOT FASTEN CONTROL JONT TO <br />WALL EVEN F STUD EXISTS <br />BEYOND EXCEPT STAPLES YV <br />V LEG MAY BE USED TO TEMIP. <br />SECURE CONTROL JOINT <br />DURING INSTALLATION <br />BRT— <br />•S1EImXTOVEEPD� <br />I' THICK 3 COAT CEMENT <br />PLASTER <br />WRB LAYER •2. FORTFIBER <br />BUILDING PAPER <br />APPROVED METAL LATH <br />FASTENED .1' (VERTU OL. MAX <br />AT SUPPORTS <br />URB LAYER At <br />STUCCO WRAP <br />IIICOD SHEATMUNG <br />L <br />LATH 6NALL NOT <br />Yrol• <br />t-aP TM <br />LX D.�NiNS ro <br />ro <br />TMR7UC4.1 CONTROL <br />JOINTS BUT <br />_ <br />BC PP STOED MID <br />TIED AT EACH SIDE. <br />PROV1E 2X4 SLOCKM4 <br />PER ASTM 0063 <br />PLACED RAT MAX. W TO V <br />1J0J4 <br />\ <br />FROM OCKTROL JOINT 04EN <br />NOTEI <br />CONTROL JOINT FALLS ON <br />/ <br />L FASTENERS FOR LATH TO BE NAILS O e I <br />i STRUCTURAL STUD <br />STAPLES N COMPLIANCE IS/ ASTM CW63 <br />2. WIRE TEES TO BE (INC. 0) 0043' MRE / <br />3. BLOCKING SNOUN MAY BE N APOFT17 \ <br />TO WALL STUDS REOSRED PER PLAN <br />OLTgLD NYAIO •rt.A <br />®Fa-o <br />OL FOLD INIINID • <br />rt. w <br />T. OEAM • rt. e <br />s aEAM • rt. c <br />OL MCI.D R!♦1MO • R. A <br />2. CREAM - IR. D <br />Fan <br />® L Fa.D RRIPIO • R. A <br />2. CIW-46E•R.D <br />3 CFDAM . Pr. C <br />A AXO M. C OVER PIT. <br />e TILL. R. C TOUCAN <br />e01TO" RJNOE <br />M <br />OORQ1 <br />^'� eH.TEe noNT <br />swA PCLD. OQ <br />Waco. <br />3 COAT CEMENT <br />(PPAUA H• a CNT <br />EUUL RPM PAPER 4R,Y'E OHI.Yl <br />Ulm LATER It <br />STUCCO URAP(r1eR'e ONLY) <br />KWK-CIR M1A614114P, (RIM <br />CUTIU <br />INSTAu KHCIPOIII <br />AT DORQ"1 ON ROOF . <br />NIURIIGTION! <br />64ALL BE LAPPED A MINIMUM OF <br />6' • VERTICAL LAPS (ROLL <br />ENDS) 4 6' • MORRONTAL LAPS. <br />ALL SEAMS NEED TO BE TAPED <br />WITH FORTIBER SIEATMINCs TAPE <br />i \ <br />LATH VERTICAL LAP TO BE 1• <br />4'K4. SELF-ADFIERNf M R41� y <br />RASNNG [COMIPATIBLIS UY HOUSE 7\ <br />YIRAP MATERIAL) OVER <br />APPROVED HOUSE URAP. <br />BASHING r0 ExroD ONTO PIPE <br />r oR LE86 PIPE <br />/ \ <br />PENETRATION <br />/ r 1•RL LM . tETK LATH \ <br />fC X <br />X X X <br />CUT AND OVERLAP ONE 61DE OR / <br />METAL LATH <br />SELF -ADHERING MEYERANE J <br />FLASNNG <br />STEP 01 <br />LURE, LAYER Al, <br />it THICK 3 COAT CEMENT <br />STUCCO WRAP <br />I <br />PLASTER <br />`• nN LAP Y <br />METAL LATH <br />URB LAYER 4, FOR'TFIOEIU <br />PAPER <br />BUILDINGSIRE, <br />UM LAYER 4, FORTFULER <br />BUILDING PAPER <br />LAYER -L <br />fflr <br />INSTALL FASTENERS, (CLIPS, <br />YROOD BFEATNR/G <br />STRAPS. <br />RECURRED TO 6EOSE <br />ECUREG <br />1 <br />/7 ` <br />PIPE) WHET TO <br />2 SCALE, I VW -I' -a <br />® KIC KO UT <br />DETAIL <br />valor thaw REAL (DBD OR <br />ROLOEP: cn NOT = <br />pj <br />VERTICAL LATH <br />& PAPER DETAIL <br />NOTE, <br />SIDE LAPS OF METAL <br />PLASTER BASES SMALL <br />BE 6ECUREO TO <br />FRAMING MEMBERS. <br />THEY SMALL BE TIED <br />ISETUMEN SUPPORTS <br />UInW 00415-N. (121-M1) <br />MRE AT INTERVALS NOT <br />MORN THAN 9• (229-M7J. <br />AS PER ASTM CI063 <br />IAL <br />FOR REPAIR OF TEARS <br />N UPm LAYERS, TEARS <br />MAY BE PATCHED <br />UUMOUBE WRAP TAPE <br />PER SPEC OR <br />PEEL 4 STICK <br />U1000 <br />BMEATI <br />BWLDI <br />PAPEP <br />6TUCG <br />s[":4v*61a 13m�10C <br />AN <br />MR <br />WOOD SHEATHING OR CMU <br />WRI3 LAYER 01, <br />STUCCO WRAP (FRAME ONLY) <br />J' THICK, 3 COAT CEMENT <br />PLASTER (FRAME), 1/1' 2 COAT <br />CEMENT PLASTER (CMU) <br />METAL LATH (FRAME ONLY) <br />LAP WRB 4 TAPE OVER <br />ROOF/WALL SCREED <br />5'X5' 'L' TYPE CONTINUOUS <br />Z GALV. METAL FLASHING <br />(NAIL TO ROOF DECK, NOT <br />WALL SHEATHING) <br />CAP SHINGLE - DO NOT NAIL, <br />INSTALL WITH ROOF CEMENT <br />ROOF PER ELEVATIONS <br />O"L" FLASHING- <br />N.T.S. <br />PIPE <br />1.I T c. <br />6 <br />4• <br />W.W SELF -ADHERING MEMBRANE <br />FLASMRYa (CQIPATIBLE W/ MOUSE <br />MAP MATERIAL) OVER 4•A4• <br />SELF-ADHERNG MEMIBRME <br />FLA614NG OVER APPROVED <br />MOUSE WRAF! <br />FLASIING TO EXTEND ONTO PIPE <br />` CUT AND OVERLAP ONE SIDE OF <br />STEP <br />n SELF-ADMIERNIM MEMBRANE <br />UIRB LAYER -L <br />STUCCO URAP <br />URB LAYER 4. FORrFIBER <br />M ULDNG PARR <br />METAL LATH <br />66N6' SELF -ADHERING MEMBRANE <br />RASMNG OVER 4'w4' <br />SELF-ADHERNCs MEMUSPIA E <br />FLASHING OVER APPROVED <br />HOUSE URAP. <br />FLASFNNG TD EXTEND OMO PIPE <br />4'A4' SELF -ADHERING MEMBRANE <br />R.ASWM OVER APPROVED <br />MOUSE )RAP. <br />FLA611NG i0 EXTEND ONTO PIPE <br />W COAT. BEAD OF SEALANT <br />INSTALL APPROVED HOUSES RAP AIR <br />INFILTRATION SAIRIRER OVER <br />ELA6TO'ERIC COATING OVER STUCCO/ <br />GV. FINISH (SEE TYP SALL SECTION) <br />SECTION PER SECTION RTU&7 <br />F)OSU WIRe 41W RLISIS <br />ExlExterioruse of Portlandnd <br />cemant plaBief <br />shall ranply with Ufa.M-tion <br />ragWremants o1 ASTM C 926-12A <br />h M."Wi.n of elcier.I.thhg and lramklg <br />Mh shalt amply IASTM C 106312A. <br />TRATI <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER *2 (FORTIFIBER ...... <br />- - - <br />BUILD ING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING - - - - - - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R"103.11 / ASTM C-S4-i-09, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdeslgngroup.com <br />AA S: 0003325 <br />RIM <br />o <br />tj <br />O <br />14 <br />StMDIV. de LOT <br />ABBOTT PARK <br />LOT #4 <br />BLK #8 <br />PROJECT* <br />04181.000-04083 <br />Ii "1408" <br />"DAKOTA" <br />GARAGE 8TrMG: <br />LEFT <br />PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />D � 11/25/19 <br />SCALE: 1/4"=1'-0" <br />SHEET <br />WA1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.