My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8046 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8046 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:12:34 AM
Creation date
2/24/2025 10:06:23 AM
Metadata
Fields
Template:
Building Plans
Street #
8046
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
22546
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
26
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BACKER ROD <br />BACKER ROD <br />WRB LAYER 9, <br />AmIrl-n nRAP <br />INSTALL 6' SELF-ADWERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDE(S) AND BOTTOM <br />FLANGES OF PION -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEdlUE*CE OF FLASHNG TO BE: <br />L BOTTOM. 2- SIDES. 3. TOP <br />VENT CAP IS TO 15E SET IN BED <br />OF SEALANT AT TOP AND <br />SIDES ONLY. SEALANT 16 TO BE <br />TOOLED SO AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />VENT -APPLY SEALANT ALL <br />JOINTS AND INTERSECTIONS <br />APPLY SEALANT AT PERIMETER OF; <br />NON -MOVABLE FRAME AND STUCCO <br />FL AALLY&Ye CAULKING 4 JOINT <br />PER SECTION R7E6.7 <br />Etderler le@ na and pNderlrg <br />Exterior use of Portland cement plaster <br />shall comply with the application <br />requirements of ASTM C 926-12A. <br />Installation of exterior lathing and framing <br />shall comply With ASTM C 1063-12A. <br />HOODED VENT <br />THICK 3 COAT CEMENT <br />1, <br />PLASTER <br />METAL LATH <br />WRB LAYER -2, FORTIFI VIER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />LEGEND <br />DRAINAGE PLANE (WR5 <br />LAYER 01, STUCCO WRAP) <br />WRB LAYER a2 (FORTIFIBER - - - - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R103.1.1 / ASTM C-841-0% MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />STUCCO <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />SELF <br />FLASHING <br />UNIT <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT • <br />TOP 4 SIDES <br />F)B DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH <br />WALL <br />1 <br />6' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPEC&) <br />BUILDING PAPER — <br />UNDER 'QUICK FLASH' <br />A VENT PENETRATION <br />SCALE: N.T.S. <br />CUT OPENING IN <br />APPROVED WOUSEULIFAP <br />FOR .BOX INSTALLATION <br />AY 9 WRB LAYER <br />STUCCO WRAP <br />UIOOD SHEATHING <br />APPROVED <br />HOUSEWRAP <br />BELOW <br />ELEC. METER FIELD i H Fill <br />VERIFY LOCATION ELEC. METER FIELD <br />VERIFY LOCATION CUT SUCH TWA <br />NO MEMISRAN <br />ENTERS BOX, <br />APPLY STUCCO SCRATCH COAT APPLY TO FA. <br />EDGE <br />AND ONE (1) LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />AREA TO RECEIVE <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEND FOAM <br />)R SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />;O SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />APPLY E-Z <br />OVER 60 MI <br />GRADE 'D' <br />FELT-PROVII <br />SEALANT AT <br />JOINTS AND <br />NTERSECTIC <br />WOOD SHEATHING <br />WRS LAYER 9, <br />STUCCO WRAP <br />WES LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />METAL LATH <br />FASTEN TO WOOD STIa1CTU RAL <br />MEMCER - T' OL. MAX <br />V To)j'M®-WALL <br />WEEP lGir. <br />S' OaDE STRIP SELF <br />ADHESIVE FLAGWIWA CLEAN <br />MASONRY EEPORE APPLYING <br />V FINISH • MASONRY <br />® HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />s• <br />URB LAYER 01, <br />STUCCO UIRAP <br />CUT 'X' INTO <br />SELF-ADI ERNG <br />? <br />MEMBRANE FLASHING <br />APPLY SELF -ADHERING <br />MEMBRANE FLASHING <br />OVER BOX AND OVER <br />APPROVED UM LAYER <br />N <br />STEP #1 <br />STEP #2 <br />LAYER 01,STU <br />STUCCO WRAP <br />STEP #3 <br />APPLY 60 MIN - <br />GRADE 'D' FELT <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUBEWRAP <br />IWA <br />® R <br />R MEMBRANEASHNG <br />WRl3 LAYER 12, FORTRBER <br />BUILDING PAFER <br />STEP #4 <br />ELASTOMERIC <br />COATNCs OVER <br />STUCCO/ C.V. FN15H <br />(SEE TYPICAL WALL <br />SECTION) <br />METAL LATH <br />STEP 05 STEP #6 <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdesWngroup.wm <br />AA #: 0003325 <br />f%q <br />w- <br />a <br />t <br />IP <br />VBDIV. dBBOTT PARK <br />LOT #3 <br />BLK. #8 <br />ROJECT# <br />04181.000-03082 <br />MODEL' <br />4EBB <br />"1828-CALI" <br />GARAGE 8111 <br />RIGHT <br />1 PAGE: <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 MPH EXP. C <br />IDEC <br />D � Il/25/19 <br />SCALE 1/4'=1'-0" <br />S* EMZTT <br />VV A2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.