HVAC NOTES <br />I. ALL MECHANICAL EQUIPMENT SHALL. BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />M1FG. REQUIREMENTS. <br />2. ALL DUCT SYSTEMS INSTALLED IN NON -CONDITIONED AREAS SHALL BE CONSTRUCTED OP A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION (2011) MECHANICAL 15LM CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NPPA WA 2-3.1 <br />4. PM814 AIR INTAKES SHALL NOT BE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />S. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALV. METAL. <br />OR OTHER MATERIALS AS PER RICO 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRICTED IN ACCORDANCE TO FEC 6TH EDITION <br />(2011) MECHANICAL CODE 603J <br />1. BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />* ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/SMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATICN AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION (2011) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH OBF BOOSTER PAN OR EQUAL. <br />FANTECH DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DIFFUSER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />BALANCING DAMPER OR OW <br />O <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUTSIDE AIR <br />8 <br />THERMOSTAT <br />m <br />PASS-THRI AIR GRILL <br />NOTE, <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />SECURE STRAP TO CONC. CONDENSER <br />ATTIC <br />W/ (2)-3/16'X2' TAP'GONS UNIT <br />SIMPSON WS ROLL STRAP <br />OR EQUAL <br />CEILING <br />O O <br />EXTERIOR WALL <br />PLENUM <br />T y <br />AIR RETURN <br />4' CONCRETE SLAB <br />SECURE STRAP TO UNIT W/ (2) <br />•8XI 1/4' BHT. MTL. SCREWS <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />y <br />REFRIGERANT LINES <br />CONDENSER <br />UNIT <br />AIR HANDLER <br />y <br />CONNECTION <br />TO PAD <br />EXTERIOR WALL <br />y <br />3/4' PVC CONDENSATE DRAIN LINE <br />NOTE, MAIN COND. DRAIN 3/4' DIA. <br />OVER HEAD • 12' FROM STRUCTURE <br />EVAP. TRAY <br />y <br />PVC SLEEVE TO LINES BELOW SLAB <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />TRAP DRAIN LINE AND TERMINATE <br />IN AN APROVED DRAIN, AS PER <br />FBCR 6TH EDITION (2011) <br />MECHANICAL BLOC. CODE <br />SECTION 3012A <br />HVAC <br />DRAINS <br />SCORIATED NICKEL <br />BRONZE FL. PL. <br />FIN. FLOOR <br />OR WALL <br />COON CO.PL LUG <br />A. PLUG <br />I <br />—* <br />� SEE SPEC. <br />�—FITTING OR EXTENSION TO <br />SOIL OR WASTE AS <br />REQUIRED <br />WADE 6240-K J06AM 560M <br />INSIDE SERIES NICKEL BRASS TOP <br />CAULK P.V.G Of-Ti/SPEC <br />OFLOOR SLAB CLEAN -OUT (T <br />FIN. GRADE <br />OR PAVING <br />PITTING OR <br />EXTENSION TO SOIL <br />OR WASTE AS <br />REQUIRED <br />NEXT. GROUND CLEAN -OUT (TYPN <br />■ <br />NOTE, <br />ALL MECHANICAL EQUIPMENT <br />SHALL BE INSTALLED AT OR <br />ABOVE F.P.E. ELEVATION <br />MECHANICAL PLAN <br />SCALE, 1/4 - P-0' <br />1441 N. RONALD REAGAN BLVD, <br />LONGMOD, FL 32760 <br />PH: 407-774.6078 <br />FAX- 407-7744078 <br />www.abdosigngroup.com <br />AA M: 0003325 A <br />: <br />y <br />R <br />R <br />q <br />O <br />:kka <br />6 <br />:kko <br />6 <br />5 <br />IP <br />BtMDIV. ae LOT: <br />BBOTT PARK <br />LOT #3 <br />BLK #15 <br />ROJECT <br />04181.006-03151 <br />1LODEII <br />4EBB <br />"1828-CALI" <br />GARAGE BMIMG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />160 MPH EXP. C <br />