My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8054 Broad Pointe Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8054 Broad Pointe Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2025 3:27:32 AM
Creation date
2/24/2025 10:04:13 AM
Metadata
Fields
Template:
Building Plans
Street #
8054
Location
Broad Pointe Dr
Contractor
D R Horton
Building Plans - Permit #
22253
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
HVAC NOTES <br />1. ALL MECHANICAL EQUIPMENT &HALL BE PROVIDED WITH PROPER CLEARANCE, FOR SERVICING, PER <br />MFG. REGUIREMEENTS, <br />T. ALL DUCT SYSTEMS INSTALLED IN NON-CONDITICNED AREAS SHALL BE CONSTRUCTED OF A VALUE <br />OF NO LESS THEN R-6 RATING. ALL SEAMS SHALL BE SEALED WITH GLASS FAB 4 MASTIC. AND <br />INSTALLED AS PER FBC 6TH EDITION 12011) MECHANICAL 81-Ca CODE SECTION 603. <br />3. ALL FLEX DUCTS SHALL BE APPROVED UL 181 CLASS I AIR DUCT AS PER NFPA SCA 2-3.1 <br />4. FRESH AIR INTAKES SHALL NOT DE LOCATED CLOSER THAN 10 FT. FROM ANY CHIMNEY OR VENT <br />OUTLET, OR SANITARY SEWER VENT OUTLET <br />D. ALL EXHAUST AND OUTSIDE AIR INLET DUCTS, SHALL BE CONSTRUCTED OF SMOOTH GALv. METAL. <br />OR OTHER MATERIALS AS PER FBC 6TH EDITION (2011) MECHANICAL CODE SECTION 603 <br />6. ENCLOSED SUPPORT PLATFORMS SHALL BE CONSTRUCTED IN ACCORDANCE TO FBC 6TH EDITION <br />(2011) MECHANICAL CODE 603.1 <br />1. BATHROOMS CONTAINING BATHTUBS, SWOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE <br />MECHANICALLY VENTED IN ACCORDANCE WITH FBC 6TH EDITION (2011) MECHANICAL CODE SECTION <br />403. <br />8. ALL EXHAUSTED BATH ROOMS, SHALL HAVE UNDER -CUT DOORS FOR MAKE-UP AIR TO BE <br />RETURNED, TO EQUAL AIR EXHAUSTED. <br />* ALL FIRE RATED CEILINGS AND WALLS SHALL HAVE AN APPROVED FIRE OR FIRE/BMOKE <br />DAMPER'S LOCATED AT CEILING OR WALL PENETRATION AND BE SLEEVED WITH ACCESS DOORS TO <br />RESET DAMPER. ALL DAMPERS SHALL BE INSTALLED TO MFG. RECOMMENDATIONS AND FBC 6TH <br />EDITION 120rl) MECHANICAL CODE SECTION 601. <br />10. GRILLES AND DIFFUSERS SHALL BE PROVIDED WITH BALANCING DAMPERS. <br />11. DRYER BOOSTER TO BE A FANTECH GBF BOOSTER FAN OR EQUAL. <br />PANTEC4 DBF 110 DRYER BOOSTER CAPACITY 60 LINEAR FEET WITH MAX. SIX ELBOWS. <br />LEGEND <br />® <br />SUPPLY AIR DIFFUSER <br />RETURN AIR GRILL <br />® <br />SIDE -WALL OR I WAY DFR46ER <br />— <br />SOLID LINE- SUPPLY TRUNK <br />— <br />BROKEN LINE- RETURN TRUNK <br />l <br />BALANCING DAMPER OR OBD <br />0 <br />CEILING EXHAUST FAN <br />CEILING EXHAUST FAN 4 LIGHT <br />O/A <br />OUT8IDE AIR <br />® <br />THERMOSTAT <br />m <br />PASS-THRU AIR GRILL <br />NOTE <br />ALL HVAC TO HAVE PROPER <br />PANS W/ DRAINS <br />ATTIC <br />CEILING <br />O O <br />EXTERIOR WALL <br />SECURE STRAP TO GONC. CONDENSER <br />PLENUM <br />1 <br />AIR RETURN W/ (2)-3A6'X2' TAPCONS SIMPSON WB ROLL STRAP <br />OR EQUAL <br />SUCTION AND LIQUID <br />AIR SUPPLY <br />1 <br />REFRIGERANT LINES <br />d <br />STRAP UNIT (T) <br />AIR HANDLER <br />EXTERIOR WALL <br />4' CONCRETE SLAB 4SX11� 6HT. MTLO <br />3/4' PVC CONDENSATE DRAIN LINE <br />CONDENSER UNIT <br />EVAP. TRAY <br />1 <br />PVC SLEEVE TO LINES BELOW SLAB <br />CONNECTION TO PAD <br />T <br />REFRIGERANT LINES TO <br />PLATFORM <br />RETURN <br />CONDENSING UNIT <br />NOTE, MAIN COND. DRAIN 3/4' DIA <br />TRAP DRAIN LINE AND TERMINATE <br />OVER HEAD • 121 FROM STRUCTURE <br />IN AN APROVED DRAIN, AS PER <br />POOR 6TH EDITION (2011) <br />MECHANICAL DLOG. CODE <br />SECTION 301.2.4 <br />HVAC <br />DRAINS <br />SCORIATED NICKEL FIN. FLOOR COUNTERSUNK <br />BRONZE PL. PL. OR WALL CA. PLUG <br />SEE SPEC. <br />a <br />BRASS PLUG I'-8'XB' CONC. <br />IrL <br />FIN. GRADEOR EXTENSION TO OR PAVING <br />R WASTE AS FITTING OR <br />EDEXTENSION TO 601L <br />240-K J08AM 56000 OR WASTE AS <br />INSIDENICKEL BRASS TOP REQUIRED <br />CAULKPTI/SPEC <br />N �INv. <br />I—�-TE P� AIJ <br />FLOOR SLAB CLEAN -OUT (TYPN. NEXT. GROUND CLEAN -OUT (TYPN) <br />■ <br />MECHANICAL PLAN <br />SCALE, 1/4 . 1'-0' <br />1441 N. RONALD REAGAN BLVD <br />LONGWOOD, FL 32750 <br />PH: 407-774-6078 <br />FAX: 407-774-4078 <br />www.abdeslgngroup.com <br />AA #: 0003325 <br />P <br />[tl <br />> <br />J <br />ass <br />11TI.L. <br />J <br />etMDIV. do L07 <br />ABBOTT PARK <br />LOT #2 <br />BLK #8 <br />PROJ=Tp <br />04181.000-02081 <br />moDzu <br />4EAB <br />"1672- ARIA" <br />GARAGE 8WMG: <br />LEFT <br />PAGE: <br />MECHANICAL <br />PLAN <br />%160 MPH EXP. C <br />DATIC: 09/12/19 <br />scAlc: 1/4"=1'-0" <br />oliEET <br />M1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.