In <br />CONCRETE SLAB w/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />° <br />° 4 <br />n /, <br />VAPOR BARRIER <br />3 BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. SEE ARCH <br />��- b.- -- - - - -- (MAX 20" <br />DEEP) <br />4" EXT�E��NSSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />BEARING CURB STEP SECTION <br />CONCRETE SLAB W/ <br />6x6 W1.4 x W1.4 WWF <br />OR FIBER MESH <br />8" CMU CHAIR <br />TOP OF SLAB BLOCK W/ (1) #4 OR #5 CONT. <br />Y v) <br />w <br />o' CO <br />J <br />w � O <br />VAPOR BARRIER / i UJ o <br />#4 OR #5 VERT REINFORCING //\\//��/ ` <br />UP TO 3 COURSES: 72" O.C. <br />4 TO 5 COURSES: 48" O.C.\\//� / /\/ j �/ - <br />\j/ <br />FOOTING TO BEAR ON FIRM //� / ADDITIONAL #4 OR#5 IN BRICK LEDGE <br />UNDISTURBED SOIL <br />VERTICAL REINFORCEMENT — 4" OPT BRICK LEDGE <br />TO HAVE 6" BEND AT BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />2 STEMWALL SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />U-0" A.F.F. <br />(BEYOND) <br />FLOATING CONCRETE - - w_ <br />SLAB W/ 6x6 W1.4xW1.4 <br />WWF OR FIBERMESH > <br />#4 OR #5 VERT REINFORCING - - -- / <br />UP TO 3 COURSES: 72" O.C. j <br />4 TO 5 COURSES: 48" O.C. - - <br />I <br />FOOTING TO BEAR ON FIRM --/ - - ADDITIONAL #4 OR <br />UNDISTURBED SOIL <br />#5 IN BRICK LEDGE <br />VERT REINFORCEMENT TO - 4" OPT BRICK LEDGE <br />HAVE 6" BEND @ BOTTOM NOTED ON FND PLAN <br />CAST -IN -PLACE FOOTING SPECS - <br />1-STORY: 8" x 16" W/(2) #4 OR (2)#5 CONT <br />2-STORY: 10" x 20" W/(3) #4 OR (2) #5 CONT <br />7 STEMWALL CURB SECTION <br />1. SPECIAL CARE SHOULD BE EXERCISED BY CONTRACTOR WHEN BACK <br />FILLING BEHIND A STEM WALL, PARTICULARLY WHEN IT IS OVER 4 <br />COURSES HIGH. SHOULD THIS CONDITION EXIST, RECOMMENDATIONS <br />MAY BE OBTAINED FROM THE ENGINEER OF RECORD. <br />2. SCREW IN ANCHORS ALLOWED IN MONOLITHIC FOOTINGS ONLY. EPDXY <br />ANCHORS MUST BE USED IN STEMWALL FOUNDATIONS. <br />U-BLOCK W/ <br />J <br />(1)#4OR#5 <br />Q <br />CONT <br />LU w <br />w � <br />FINISH <br />_ O <br />GRADE <br />(1) #4 OR #5 CONT. <br />36" MAX "VARIES PER <br />ARCH PLANS <br />12" MIN <br />MINIMUM 24" <br />a <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR FIBERMESH <br />(1) #4 OR #5 90" BEND @ 48" O.C. <br />VAPOR BARRIER <br />FOOTING TO BEAR ON FIRM <br />UNDISTURBED SOIL <br />6" OPT. EXTENSION <br />IN BRICK LOCATIONS <br />ON FND PLAN <br />12" UNDER 1 STORY WALL w/ <br />ADDITIONAL NO.4 OR NO. 5 (2) #5 OR (2) #4 CONTINUOUS <br />BAR IN BRICK LEDGE - - - - <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS <br />1 MONOLOTHIC FOOTING SECTION - 36" MAX DEPTH <br />*NOTE*: IT IS ACCEPTABLE TO SUBSTITUTE THIS "1A" FTG DETAIL FOR THE <br />"I" FTG DETAIL SPECIFIED ON THE FDN PLAN @ ANY LOCATIONS THAT THE FTG <br />DEPTH EXCEEDS 28". <br />IF GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY FROM STRUCTURE <br />STEEPER THAN 1'-0" VERTICALLY PER X-0" HORIZONTALLY, CONTRACTOR HAS <br />TWO CHOICES: <br />1. PRIOR TO CONSTRUCTION, SEEK GUIDANCE OF FOR TO PREVENT EROSION <br />OF SOIL. <br />2. USE STEMWALL FOOTING <br />CONCRETE SLAB W16x6 <br />W1.4 x W1 4 WWF OR <br />FIBERMESH <br />//; <br />VAPOR BARRIER / <br />FOOTING TO BEAR ON 6" OPT. EXTENSION IN BRICK <br />FIRM UNDISTURBED LOCATIONS ON FND PLAN <br />SOIL <br />12" UNDER 1 STORY WALL w/ <br />(2) #5 OR (2) #4 CONTINUOUS <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS J <br />1 MONOLITHIC FOOTING SECTION - <br />CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />FROM STRUCTURE STEEPER THAN V-0" VERTICALLY <br />PER T-0" HORIZONTALLWO PREVENT EROSION OF SOIL. <br />CONCRETE SLAB w/ 6x6 <br />(2) #4 OR (2) #5 CONTINUOUS W1.4 x W1.4 WWF OR <br />FIBERMESH <br />- - - - - - - 4 <br />:X <br />/ VAPOR BARRIER <br />16" <br />ADDITIONAL NO. 4 OR NO. 5 <br />BAR IN BRICK LEDGE <br />3 BEARING WALL FOOTING SECTION <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0'-0" A.F.F. <br />0 <br />8"x8" THICKENED 8" I <br />FTG AT <br />STEP-DOWN, SEE <br />PLAN <br />�4 <br />- SEE ARCH <br />_ DETAILS <br />8" MIN <br />VAPOR BARRIER <br />CURB STEP SECTION <br />8" UNDER MASONRY WALL <br />f- - -i <br />CONCRETE SLAB W/ 6" UNDER WOOD WALL - <br />6x6 W1.4 x W1.4 WWF <br />OR FIBERMESH r ° <br />VARIES t SEE ARCH <br />I— - -- n-•- —-----r-•----- -- --'—�a <br />(MAX 16") <br />� 12" MIN % \,/ <br />VAPOR BARRIER <br />6" OPT. EXTENSION IN BRICK <br />LOCATIONS ON FND PLAN <br />12" UNDER 1 STORY WALL w! 1 <br />(2) #5 OR (2) #4 CONTINUOUS ADDITIONAL NO. 4 OR NO. 5 <br />-- BAR IN BRICK LEDGE <br />16" UNDER 2 STORY WALL w/ <br />(2) #5 OR (3) #4 CONTINUOUS <br />1 � '\,-GARAGE EXT WALL CURB SECTION__- <br />/i CONTACT FOR PRIOR TO CONSTRUCTION IF ANY OF THE <br />FOLLOWING OCCUR: <br />• OVERALL DEPTH OF MONOLITHIC POUR EXCEEDS 28" <br />• GROUND ADJACENT TO FTG SLOPES DOWN AND AWAY <br />FROM STRUCTURE STEEPER THAN 1'-0" VERTICALLY <br />PER S-0" HORIZONTALLWO PREVENT EROSION OF SOIL. <br />CONCRETE SLAB W/ 6x6 <br />W1.4 x W1.4 WWF OR <br />FIBERMESH <br />0' _0" A.F.F. SEE ARCH <br />-< --- — — — -- -- — (MAX 20" <br />e <br />DEEP) <br />°-r----- -- <br />4" EXTENSION <br />UNDER BRICK VENEER <br />12" UNDER 1 STORY WALL <br />w/ (2) #4 OR (2) #5 CONT _ VAPOR BARRIER <br />16" UNDER 2 STORY WALL <br />W/ (3) 44 OR (2) #5 CONT J <br />i BEARING CURB STEP SECTION <br />�I <br />TYPICAL REINFORCING <br />BARS AT THICKENED <br />FOOTING, SEE PLAN <br />i l li I <br />MIN 24" LUNG #4 OR #5 <br />BAR SET AT MID -DEPTH <br />OF SLAB, TYP ALL <br />RE-ENTRANT CORNERS <br />HOUSE SLAB <br />RE-ENTRANT CORNER DETAIL <br />(RECOMMENDED) <br />PLAN VIEW, DETAIL TYPICAL @ ALL <br />RE-ENTRANT CORNERS <br />U <br />0 <br />rn <br />N L0 Q <br />r` <br />O ° <br />APEX <br />w <br />m <br />W y <br />W <br />z <br />(D d t S <br />W <br />Q true design studios Q <br />0 <br />-1 9000 REGENCY SQUARE BLVD. N <br />W SUITE 100, JACKSONVILLE, FL 32211 <br />z co <br />0 904.821.5200 p <br />Q cn <br />0 <br />� 11HOMON' <br />(1) <br />U <br />0 # N �• <br />0 <br />J <br />LL <br />U <br />z <br />O <br />O <br />z <br />2 <br />U <br />W <br />X <br />W � ♦♦ ^^ <br />Q VJ <br />O M W <br />� W <br />m <br />p Z W <br />W cl) 0 U) <br />a - O <br />W Q 0 <br />2 <br />z m > o <br />0 J W <br />a <br />M W NW a <br />I— 0L p <br />U LL W <br />LL <br />Q ti <br />x <br />O 0 <br />Z W = <br />U z <br />Z <br />I-- Abbott Park <br />X CL <br />a LOT 002-02-A w <br />Q J <br />Q <br />U <br />W <br />PROJECT NO: i- <br />2020.001719 z <br />DRAWN: <br />S LC L�LI <br />p <br />CHKD. EAF LL <br />O <br />LA <br />V) <br />♦�.� J IN• w <br />LAN�� <br />ENs ••9 <br />CU <br />51 6 •• <br />0 <br />Z <br />• . <br />ST E OF � <br />,0�• <br />U) <br />02-26-2020 O <br />Z_ <br />REVISIONS: <br />No. Description Date p <br />W <br />W <br />J <br />- -- --- V <br />U) <br />ST <br />z =2 ■ D O <br />p <br />CMU/METAL CONNECTOR ENGINEERING <br />