Laserfiche WebLink
)ocuSign Envelope ID: C1 150073-72El 4C6A-B7I3F-94DA94F65BB3 <br />L <br />1/2" (MIN) STUCCO <br />FINISH TEXTURED <br />PER COMMUNITY <br />SPECIFCATIONS <br />FLANGE CASING <br />BEAD <br />CASING BEAD at WN <br />SCALE N.T S. <br />5/8" CEMENT PLASTER <br />12" WIDE SELF-ADHESIVE <br />FLASHING CENTERED UNDER <br />CONTROL JOINT (CLEAN <br />MASONRY BEFORE APPLYING) <br />PRE -FORMED CONTROL <br />JOINT W/ STRIP LATH <br />8" CMU <br />ht <br />C, ONTROL JOINT - HORIZ - CMU <br />SCALE: N.T.S. <br />VINYL ANGLED <br />CASING BEAD <br />> <br />(AM66-ANGLED-1 250) <br />Vq <br />Z <br />z LD <br />m Uj <br />W <br />LULD _l <br />LU LU <br />LL <br />< <br />> <br />)K' <br />x <br />X. <br />VINYL CASING <br />BEAD (AM66-1250) <br />1/2" (MIN) TEXTURED <br />FINISH at MASONRY <br />1"AISED BAND at BLOCK <br />SCALE: N.T.S. <br />E) uVER <br />PRE -SHAPED STUCCO BAND <br />�LD <br />W/ SLP TOP INSTALLED PER <br />p1[ STRIPS <br />MFR WRITTEN SPECS (RE: <br />N"I "Al'! ijyp) <br />EL EV) <br />SELF ADHESIVE -OR- FLUID <br />APPLIED FLASHING (CLEAN <br />MASONRY BEFORE APPLYING) <br />A)!) BUCK—/ <br />VINYL FLANGE CASING BEAD <br />r. if FI)ED—/ <br />INSTALLED PER MFR <br />WRITTEN SPECS (TYP) <br />%" BACKER ROD W/ SEALANT <br />;-RIOR <br />EXTERIOR <br />HEAD <br />at CMU <br />SCALE: 1 ti2" = 1'-0" <br />PRE -FORMED CONTROL 5/8" CEMENT PLASTER <br />JOINT W/ STRIP LATH <br />12" WIDE SELF-ADHESIVE <br />FLASHING CENTERED UNDER <br />CONTROL JOINT (CLEAN <br />MASONRY BEFORE APPLYING) <br />CONTROL JOINT - VERTICAL - CMU <br />I SCALE: N.T.S. <br />CORNER BEAD <br />(FASTENER & <br />SPACING at 7"O.C,) <br />CMU <br />1/2" (MIN) STUCCO FINISH <br />. TEXTURED PER COMMUNITY <br />-A <br />SPECIFCATIONS <br />CORNER BEAD at BLOCK <br />SCALE: N.T.S. <br />CMU WALL W/ <br />48" STUCCO FINISH <br />RE. STRUCTURAL) <br />GYP BRD OVER <br />PRE -SHAPED STUCCO BAND <br />1x2 TREATED <br />W/ INSTALLED PER MFR <br />FURRING STRIPS <br />WRITTEN SPECS (RE: ELEV) <br />at CMU WALL (TYP) <br />WOOD BLOCKIN <br />SELF ADHESIVE -OR- FLUID <br />APPLIED FLASHING (CLEAN <br />MASONRY BEFORE APPLYING) <br />PT 1 x WOOD BUCK <br />VINYL FLANGE CASING BEAD <br />SHIM AS NEEDED <br />INSTALLED PER MFR <br />WRITTEN SPECS (TYP) <br />48" BACKER ROD W/ SEALANT <br />INTERIOR <br />EXTERIOR <br />WINDOW JAMB <br />at CMU <br />SCALE: 1 �2" = 1'-101" <br />STUCCO FINISH <br />6" SELF ADHESIVE <br />OVER TOP & SIDES <br />SELF FLASHING <br />UNIT <br />PREMANUF. <br />DRYER VENT CAP <br />(SET IN CONT. <br />SEALANT) <br />SEALANT at <br />TOP & SIDES <br />DRYER VENT (BLOCK) <br />SCALE: N.T.S. <br />6" SELF -ADHERING <br />FLASHING <br />WEATHER RESISTIVE <br />BARRIER #1 <br />WEATHER RESISTIVE <br />BARRIER #2 <br />6" SELF -ADHERING <br />FLASHING <br />GALVD MI <br />"Z" FLASI <br />r)n NOT (,8 <br />—.1 — <br />SEAL OPENING <br />1 1/4"X6" SIMULATED <br />WOOD TRIM MEMBER <br />Cr:Al r'-AD %A// CAULKING <br />OR APPROVED SEALANT <br />STUCCO CASING BEAD <br />SIDING TO STUCCO <br />FRAME TO BLOCK <br />SELF ADHESIVE -OR- FLUID <br />APPLIED PAN FLASHING (CLEAN <br />MASONRY BEFORE APPLYING) <br />EXTEND UP AT JAMBS (4"MIN) <br />PRECAST CONCRETE SILL <br />BACKER ROD W/ SEALANT <br />VINYL FLANGE CASING BEAD <br />GYP BRD OVER INSTALLED PER MFR <br />1x2 TREATED WRITTEN SPECS (TYP) <br />FURRING STRIPS CMU STEMWALL W/ <br />at CMU WALL (TYP) %" STUCCO FINISH <br />(RE: STRUCTURAL) <br />INTERIOR EXTERIOR <br />WINDOW SILL at CMU <br />SCALE: 1 ti2" = 1'-0" <br />ELECTRIC METER — <br />FIELD VERIFY <br />LOCATION <br />AREA TO RECEIVL .-j <br />STUCCO SCRA 1-CH COZ;' I <br />& 1 COAT OF PAINT WI <br />BACK -ROLL PRIOR TO <br />ELECTRIC METER <br />INSTALLATION <br />{X <br />ELECTRIC METER <br />FIELD VERIFY LOCATION <br />APPLY STUCCO SCRATCHCOAT AND ONE (1) <br />LA,'ER OF PAINT PRIOR TO INSTALLING ELECTRIC <br />i"OETCR <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLYBLEN <br />FOAM ('GREAT STUFF" OR <br />ELECTRICAL CONDUIT PENETRATION <br />WOOD CONST BEYOND <br />WOOD SHEATHING <br />WEATHER RESISTIVE <br />BARRIER #1 <br />WEATHER RESISTIVE <br />BARRIER #2 <br />5/16" X 7 1/4" LAP <br />SIDING W/ 6 REVEAL <br />STARTER STRIP <br />DO NOT CAULK OR <br />SEAL OPENING <br />GALV'D METAL "Z" <br />FLASHING <br />1 1/4" X 6" SIMULATED <br />WOOD TRIM MEMBER <br />STUCCO <br />CASING BEAD <br />SCALE: N.T.S. <br />0llVllL^m) <br />APPLY A SILICON BASE <br />SEALANT AT POINT THAT <br />ELEC WIRE PENETRATES <br />PROVIDE STUCCO <br />SCRATCH COAT LARGER <br />THAN THE ELECTRIC <br />METER CAN OR METER <br />CAN COMBO OR METER <br />CAN AND DISCONNECT <br />SCALE: N.T.S <br />FIBERCEMENI -OR- VINYL LAP <br />SIDING OVER APPROVED <br />HOUSE -WRAP INSTALLED PER <br />FIN131-1 CX)/k'FlNG OVER MFR WRITTEN SPECIFICATIONS <br />S 31_!1)(_:(-,0 FlNlz'�`l EXTEND HOUSEWRAP <br />f',ALV I'A I L I /""TI i OVER NAILING FLANGE <br />WD SHEATHING J II cwi__R1 , A FFLIF OVER , <br />(RE: STRUCT) 'I VA 1I.:A] I iING <br />[:-Az, I LN i <br />MTL DRIP FLASHING W/ <br />HEMMED EDGE SET IN CONT <br />BEAD OF SEALANT <br />TRIM (RE: ELEVATION) <br />< <br />EXTEND 12' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />WINDOW FLANGE SET IN CONT <br />f'­\PJIFJE STRIP SELF ADHESIVE BEAD OF SEALANT <br />fLASHING, CLEAN MASONRY <br />VINYL FLANGE CASING BEAD <br />BEFOR'r APPLYING -2 <br />INSTALLED PER MFR <br />1/2" r Nift �, I'L)CCO FINISH WRITTEN SPECS (TYP) <br />x �Yj <br />TLXTUED RPER (,OMI\AUNI_!`Y <br />SPCCIF(1'A710N5 1/2" (MIN) STUCCO FINISH <br />X <br />TEXTURED PER COMMUNITY <br />�xn <br />SPECIFCATIONS <br />�'_+_ JV <br />STUCCO, SIDING. <br />HORIZONTAL MATE R1A,L__1_RANS ITION (FRAME TO BLOCK) <br />SCALE: N.T.S. <br />ivii IN <br />(RE. SJRUCFORAI.; <br />12" GYP BRD OVER <br />1x2 TREATED <br />FURRING STRIPS <br />at CMU WALL (TYP) PF;,j_' <br />C), 'LAN - <br />PT 1 x4 <br />PT 2x4 FRAME ANCHOR <br />SHIM AS NEEDED NEEDED <br />V <br />INTERIOR (-)H, <br />DOOR HEAD at CMU <br />SCALE: 1 = 1:-0" <br />CMU WALL W/ <br />1/2" (MIN) STUCCO FINISH <br />(RE: STRUCTURAL) <br />GYP BRD OVER <br />"'MU! TYP) <br />CONTINUOUS BEAD <br />OF SEALANT <br />PT 9y I <br />SELF ADHESIVE -OR- <br />FLUID FLUID APPLIED <br />FLASHING (CLEAN <br />MASONRY BEFORE <br />A <br />APEYATI MO R FRAME <br />V <br />INTERIOR <br />EXTERIOR <br />DOOR JAMB at CMU <br />SCALE: 1 ti2" = 1'-0" <br />E <br />0 <br />LO <br />r1_ >: <br />a <br />b 0 <br />0 <br />z c <br />APEX <br />m <br />w I <br />LU <br />LLI <br />Z_ <br />0 <br />z <br />LLI tds <br />< true design studios4) <br />0 <br />j 9000 REGENCY SQUARE BLVD. 4) <br />Z SUITE 100, JACKSONVILLE, FL 32211 "; <br />cn <br />904.821.6200 0 <br />0 <br />0 <br />11H MON <br />0 <br />IF 4- <br />< # <br />0 <br />LL <br />< <br />0 <br />z <br />0 <br />_j <br />0 <br />Z <br />Lij <br />F_ <br />x <br />LLI <br />0- <br />< U) <br />x w LU <br />z Lu <br />W <br />0 <br />Z <br />U) <br />3: <br />0 <br />wi>J Q 0 <br />z w <br />oI W <br />W W <br />I-_ < <br />00 � 0 <br />0 LL LU <br />U_ <br />< <br />U) x <br />0 <br />o 0z <br />j <br />0 0 <br />Z w <br />m I-_ <br />0 z <br />w <br />Abbott Park <br />w U- <br />LOT 006-02 w <br />U) <br />0 <br />w <br />PROJECT NO: <br />2020.004116 z <br />DRAWN: U) <br />DO w <br />0 <br />CHKD: U_ <br />JAC 0 <br />O <br />LO <br />cn <br />w <br />U) <br />Z_ <br />0 <br />06-08-2020 <br />z <br />REVISIONS: <br />No. Description Date WI <br />U) <br />LLI <br />LIJ <br />_j <br />< <br />0 <br />U) <br />0 <br />z <br />A501 0 <br />0 <br />