Laserfiche WebLink
)ocuSign Envelope ID: 4210BE37-OE63-44AD-A2D4-OAF711104AC9 <br />TRUSS TO TOP PLATE, MOISTURE BARRIER-J <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/H8ORH10 <br />• TRUSS LENGTH </ 10 FT VERT. REINFORCING TO --/ <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 k" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x— NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />W THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />W WEDGE BOLT W/ MIN 4'/z' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />/ <br />/i,`�1///�1//i i/ <br />BOTTOM PLATE ANCHOR NOTES <br />• EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />• INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />ROOF-] <br />CONP <br />U <br />0 <br />2x NO 2 SYP BLOCKING TO FIT TIGHT .- <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ N <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" — — . — — — <br />FOR MISLOCATION 18"<X<1k" — <br />3/4" BETWEEN TOP OF WOOD PANEL FASTEN 2x6 NO. 2 SYP SHIM #5 CONT. <br />AND CENTER OF FASTENERS. TO TRUSS W/ MIN (10) 10d <br />(1) #5 BAR CONT. I <br />MIN 1%2" EXPOSURE 1 PLYWOOD RIM @ RAISED FOR MISLOCATION 1 k " <X <br />HEEL TRUSSES INSTALLED WITH LONG INSTALL NEW MASONRY TWIST a <br />DIMENSION PERPENDICULAR TO TRUSS END STRAP TO INSIDE FACE <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL-. <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />POURED CELL w #5 BAR CONT <br />FROM BEAM TO FOOTING <br />STEP DOWN TIE -BEAM <br />DIST FROM DOOR JAMB <br />MIN. SCREW <br />DIST. FROM DOOR JAMB <br />MIN. SCREW <br />/ WINDOW TO BLOCK <br />LENGTH <br />/ WINDOW TO BLOCK <br />LENGTH <br />OR 1%4" <br />PER MANUF. <br />3" <br />5" <br />11/y <br />3 4" <br />3 7� s <br />5" <br />11 5/16 <br />3 /4 , <br />3 3/4 - <br />6„ <br />2 %4" <br />33/4" <br />TITEN OR TAPCONS SCREWS SEE TABLE <br />ABOVE FOR LENGTH: <br />• (2) ROWS ''YV DIA. @ 30" O.C. STAGGERED <br />• (2) ROWS %fi' DIA. @ 24" O.C. STAGGERED <br />DOOR JAMB OR WINDOW ATTACH TO <br />1x- PER MANUFACTURER'S DETAILS <br />t-T <br />DISTANCE FROM BLOCK TO DOOR <br />JAMB OR WINDOW, SEE TABLE <br />o <br />ABOVE (SHIM AS NEEDED TO <br />PLUMB JAMB, DO NOT EXCEED 'W) <br />1x_ PT NAILER <br />BUILT UP 2x ATTACHED TO MASONRY, (1) PLY <br />1x_ OR �g OSB MATERIAL MAY ATTACH TO WALL <br />DRYWALL <br />8" CMU WALL <br />TYPICAL DOORMINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />ti <br />LLO <br />r- <br />O <br />z <br />cn <br />w <br />z <br />m <br />w <br />w <br />z <br />(D <br />z <br />w <br />O <br />J <br />LL <br />O <br />O <br />0 <br />12- <br />0 <br />O <br />J <br />LL <br />a <br />U <br />z <br />0 <br />O <br />-i <br />z <br />TZ <br />w <br />H <br />x <br />w <br />a. <br />m <br />O <br />a <br />U) <br />O <br />U <br />a <br />0 <br />J <br />O <br />z <br />2 <br />U <br />w <br />x <br />w <br />a <br />a <br />O <br />U <br />i7 <br />APEX 0 <br />O <br />t d ci <br />S -6 <br />true design studios N <br />9000 REGENCY SQUARE BLVD. N <br />SUITE 100, JACKSONVILLE, FL 32211 <br />904.821.5200 cn <br />0 <br />N <br />041HOMON' <br />K" <br />w <br />Q <br />W <br />W <br />a <br />cn <br />z <br />Q <br />Q <br />2 <br />m <br />aW <br />W <br />J <br />� <br />III <br />M w <br />� o <br />Q L.L w <br />r- <br />x <br />z <br />O <br />0 <br />w <br />H <br />z <br />Abbott Park cr- <br />0- <br />LL <br />LOT 016-02 w <br />U <br />0 <br />w <br />PROJECT NO F- <br />2021.006635 z <br />DRAWN: <br />JAR w <br />0 <br />CHKD: MJ P LL <br />O <br />0 <br />0 <br />LO <br />`,`���►�iirrrrr,r�� cn <br />♦♦♦♦ �s, (\N LqMii, w <br />♦ •.•9 J <br />U <br />No 85166 <br />Z r <br />r <br />U) <br />Do*jSigned by: /}. UI <br />r�• •�i i z <br />TA OF <br />Q •• ob <br />SS 0NA E`% 0 <br />rrri�t � <br />05-18-2021 O <br />z <br />REVISIONS: <br />No. FIDlescription Date cl <br />-- -- w <br />_ w <br />w <br />ST <br />z =5 O <br />0 <br />CMU/METAL CONNECTOR ENGINEERING <br />