My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8362 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8362 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:28:58 PM
Creation date
2/24/2025 10:17:29 AM
Metadata
Fields
Template:
Building Plans
Street #
8362
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
3069
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: 44AFD156-ODDO-42C9-9CO6-36A957C723F8 <br />TRUSS TO TOP PLATE, <br />UNO: <br />• TRUSS LENGTH > 10 FT <br />W/ H8 OR H10 <br />• TRUSS LENGTH </ 10 FT <br />W/ H2.5T OR RT7AT OR <br />SDWC15600 <br />I% <br />MOISTURE BARRIER ' <br />BETWEEN MASONRY AND <br />NON -PT LUMBER BY OTHERS <br />VERT. REINFORCING TO <br />HAVE 10" STANDARD <br />HOOK INTO BOND BEAM <br />• EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />TYPICAL ROOF DECK <br />SHEATHING. SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 k" IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1. <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x— NO. SPF OR BETTER @ MAX 16" O.C. <br />BOTTOM PLT ANCHOR <br />%" THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />1/2' WEDGE BOLT W/ MIN 4%' EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />• EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />• INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />lie <br />\ >/ \\//\\\\/\� <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />TYI <br />ROOF -TO' <br />CONNEC <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />3/4" BETWEEN TOP OF WOOD PANEL <br />AND CENTER OF FASTENERS. <br />MIN 1%2' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />HEEL TRUSSES INSTALLED WITH LONG <br />DIMENSION PERPENDICULAR TO TRUSS END <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 11" <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />FOR MISLOCATIO <br />FASTEN 2x6 NO. 21 <br />TO TRUSS W/ MIN ( <br />FOR MISLOCATIOI <br />INSTALL NEW MAE <br />STRAP TO INSIDE <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />U <br />0 <br />N <br />0 <br />N <br />I - CORNERS <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOORJAMB <br />/ WINDOW TO BLOCK <br />MIN. SCREW <br />LENGTH <br />DIST. FROM DOORJAMB <br />/ WINDOW TO BLOCK <br />MIN. SCREW <br />LENGTH <br />OR 11/4" <br />PER MANUF. <br />3" <br />5" <br />11/2' <br />3/4, <br />3 46 <br />5„ <br />115/16 <br />33/4 <br />3 <br />2141 <br />3 3/4„ <br />TYPICAL DOORAMNDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) <br />O <br />O <br />N <br />u7 <br />N <br />00 <br />Ili <br />O <br />N <br />N <br />M <br />J <br />LL <br />W <br />J <br />J <br />z <br />O <br />U) <br />Y <br />U <br />0 <br />O <br />W <br />I— <br />J <br />m <br />W <br />07 <br />z <br />W <br />0 <br />W <br />W <br />O <br />O <br />O <br />CA <br />I <br />ti <br />d' <br />L0 <br />z <br />M <br />U) <br />W <br />0 <br />m <br />w <br />W <br />z <br />z <br />W <br />¢ <br />Of <br />0 <br />I.L. <br />O <br />O <br />a <br />0 <br />U <br />¢ <br />O <br />LL <br />U <br />z <br />} <br />0 <br />O <br />O <br />z <br />_ <br />U <br />W <br />I— <br />x <br />W <br />a <br />¢ <br />x <br />a <br />00 <br />W <br />O <br />O <br />i= <br />U <br />W <br />0 <br />O <br />..J <br />O <br />z <br />U <br />W <br />H <br />x <br />W <br />W <br />APEX <br />tds <br />true design studios j <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />C <br />a <br />DiRsH0190N <br />8 <br />V <br />N <br />This item has been electronically <br />signed and sealed by Justin M Lanier, <br />PE on the date and/or time stamp <br />shown using a digital signature. <br />Printed copies of this document are <br />>Mof considered signed and sealed <br />nd the signature must be verified <br />by a 3rd Party Certificate Authority <br />�n any electronic copy I _ <br />w <br />LL W <br />J Z w <br />LU O cn <br />Z> ❑ < L <br />im w o 0 <br />❑ J w Lij <br />w <br />w <br />x <br />c— <br />LL <br />Q z <br />0 <br />W <br />I— <br />z <br />LL <br />W <br />Abbott Park Q <br />U <br />rA <br />LOT 030-02 0 <br />--- _ w <br />z <br />0 <br />0 <br />PROJECT NO: W <br />2021.011077 0 <br />LL <br />O <br />DRAWN: <br />KM E o <br />O CHKD_In <br />MJP <br />W <br />J <br />U <br />%% i %N LAN <br />ENSF. z <br />♦ '• No 85166 <br />Docu3igned by: <br />¢ <br />j iDAe)Fr435.: 441: <br />i <br />0WT' 'c P.•'��� <br />N Ai I%%0``�` <br />09/16/2021 <br />w <br />REVISIONS: w <br />2 <br />No. Description Date ~ <br />--- W <br />J <br />U <br />- cn <br />I— <br />z <br />O <br />0 <br />ST=5 <br />CIA METAL CONNECTOR ENGINEERING¢ <br />
The URL can be used to link to this page
Your browser does not support the video tag.