My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
8378 Wheat Stone Dr
Zephyrhills
>
Building Department
>
Building Plans
>
8378 Wheat Stone Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 5:38:32 PM
Creation date
2/24/2025 10:17:40 AM
Metadata
Fields
Template:
Building Plans
Street #
8378
Location
Wheat Stone Dr
Contractor
D R Horton
Building Plans - Permit #
3071
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
17
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID: A9D5FC77-63E6-4898-AFC9-7585D96187ED <br />TRUSS TO TOP PLATE, MOISTURE BARRIER -/ <br />UNO: BETWEEN MASONRY AND <br />• TRUSS LENGTH > 10 FT NON -PT LUMBER BY OTHERS <br />W/ H8 OR H10 <br />. TRUSS LENGTH </ 10 FT VERT. REINFORCING TO <br />W/ H2.5T OR RT7AT OR HAVE 10" STANDARD <br />SDWC15600 HOOK INTO BOND BEAM <br />. EVERY OTHER STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 - <br />MAX 32" O.C. <br />• EVERY KING STUD TO TOP PLATE <br />W/ SP2 OR SPT24 OR SDWC15600 <br />IC <br />TYPICAL ROOF DECK <br />SHEATHING, SEE TABLE 2: <br />WOOD STRUCTURAL PANEL <br />SHEATHING REQUIREMENTS <br />ON SHEET ST-1 <br />TRUSS OR RAFTER TO BOND <br />BEAM W/ META12 OR HTA16-18 <br />W/ MIN (7) 10d x 1 ti " IN TRUSS <br />(NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, <br />ATTACH TRUSS TO BOND <br />BEAM W/ HTSM20 OR HTWM20) <br />FASCIA (SEE <br />ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED <br />SOFFIT MATERIAL <br />CONTINUOUS @ PERIMETER. <br />SEE TABLE 1: COMPONENT <br />AND CLADDING DESIGN <br />PRESSURES ON SHEET ST-1 <br />(1) COURSE CMU BOND <br />BEAM W/ #5 CONTINUOUS <br />WALL SECTION AT ROOF (COMMON HEEL CONDITION) <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />• EVERY OTHER STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />• EVERY KING STUD TO BOTTOM PLATE <br />W/ SP1 OR SPT22 OR SDWC15450 <br />2x_ NO. SPF OR BETTER @ MAX 16" O.C. <br />W THREADED ROD ANCHOR W/ MIN 4" <br />EMBED W/ NUT & WASHER IN SIMPSON <br />ACRYLIC -TIE OR EQUIVALENT <br />ADHESIVE @ MAX 48" O.C. <br />OR <br />'/z' WEDGE BOLT W/ MIN 4%" EMBED W/ <br />WASHER @ MAX 48" O.C. <br />BOTTOM PLATE ANCHOR NOTES <br />'EACH SILL PLATE SHALL HAVE A MIN. <br />OF (2) BOTTOM PLATE ANCHORS. <br />■ INSTALL ANCHORS WITHIN 12" OF EACH <br />END OF SEGMENT (BUTT JOINTS). <br />INTERIOR LOAD BEARING WALL <br />EXTERIOR WALL <br />TYPICAL WALL SECTION AT FOUNDATION <br />(THIS SECTION IS TYPICAL FOR ONE AND TWO STORY APPLICATIONS) <br />8" PARTIALLY GROUTED <br />EXTERIOR CMU WALL W/ <br />VERTICAL WALL REINFORCING <br />PER STRUCTURAL PLAN, <br />SHEET ST-3 <br />OR ST-2A (IF APPLICABLE) <br />PROVIDE DOWELS TO MATCH <br />VERTICAL_ WALL <br />REINFORCING W/ MIN 30" LAP <br />(IF DOWEL IS OMITTED OR <br />IMPROPERLY INSTALLED, <br />DRILL AND EPDXY DOWEL OF <br />EQUAL SIZE W/ MIN. 6" <br />EMBEDMENT IN MONOLITHIC, <br />12" EMBEDMENT IN <br />MASONRY) <br />ROOF-7 <br />CONP <br />U <br />0 <br />2x NO 2 SYP BLOCKING TO FIT TIGHT <br />BETWEEN TRUSSES, (3)10d TOE -NAIL @ <br />N <br />EACH END, BLOCKING MAY BE OMITTED <br />FOR HEEL HEIGHTS < 9" <br />FOR MISLOCATION Y "8 <X<1 Y <br />3/4" BETWEEN TOP OF WOOD PANEL <br />FASTEN 2x6 NO. 2 SYP SHIM <br />#5 CONT. <br />AND CENTER OF FASTENERS. <br />TO TRUSS W/ MIN (10) 10d <br />(1) #5 BAR CONT. <br />MIN 1%2' EXPOSURE 1 PLYWOOD RIM @ RAISED <br />FOR MISLOCATION 1 k " <X <br />HEEL TRUSSES INSTALLED WITH LONG <br />INSTALL NEW MASONRY TWIST <br />a <br />DIMENSION PERPENDICULAR TO TRUSS END <br />STRAP TO INSIDE FACE <br />" <br />. _ <br />g <br />VERTICALS, ATTACH TO TRUSSES AND <br />BLOCKING W/ 10d @ 3" O.C. <br />FASCIA (SEE ARCHITECTURAL) <br />PROPERLY WIND LOAD RATED SOFFIT <br />MATERIAL CONTINUOUS @ PERIMETER. <br />SEE DESIGN CRITERIA AND LOADS: C&C <br />DESIGN PRESSURES ON SHEET ST-1. <br />TRUSS OR RAFTER TO BOND BEAM W/ <br />META12 OR HTA16-18 W/ MIN (7) 10d x 1 <br />IN TRUSS (NOTE: IF META12 OR HTA16-18 <br />IS IMPROPERLY INSTALLED, ATTACH <br />TRUSS TO BOND BEAM W/ HTSM20 OR <br />HTWM20) <br />WALL SECTION AT ROOF (RAISED HEEL CONDITION) <br />THIS DETAIL IS APPLICABLE FOR BOTH 1 & 2 STORY APPLICATIONS <br />GENERAL NOTES APPLICABLE TO ALL: <br />MISLOCATED TRUSS ANCHORS <br />BLOCKING NOT SHOWN FOR CLARITY <br />(1) #4 OR #5 BAR AT CORNERS <br />WITH MIN. 25" LAP <br />8" CMU BOND BEAM <br />BOND BEAM REINFORCING <br />AT CORNERS <br />ALTERNATE WALL SECTIONS & TYPICAL DETAILS <br />1. ALL TOP PLATES ARE TO BE BUILT WITH (2)2x_ NO. 2 SYP FASTENED W/ (2) ROWS 10d @ 8" O.C. STAGGERED (UNO). MINIMUM 48" LAP W/ MINIMUM <br />(20)10d IN LAP. ADJUST TYPICAL NAIL SPACING AS NEEDED. <br />2. ALL EXTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />3. ALL INTERIOR BOTTOM PLATES ARE TO BE 2x_ NO 2 SYP PT. <br />4. ALL INTERIOR LOAD BEARING WALL STUDS ARE TO BE MINIMUM 2X4 NO 2 SPF AT 16" O.C. UNLESS NOTED OTHERWISE ON FRAMING PLAN. <br />5. FOR SHEATHING SIZE AND FASTENING REFER TO TABLE 2: WOOD STRUCTURAL PANEL SHEATHING REQUIREMENTS ON SHEET ST-1. <br />6. FOR EXTERIOR WALL STUD SIZE AND SPACING, REFER TO TABLE 3: MAXIMUM EXTERIOR WALL STUD SIZES ON SHEET ST-1. <br />7. FOR EXTERIOR CMU WALL VERTICAL WALL REINFORCING, REFER TO DOWEL PLACEMENT PLAN ON SHEET ST-2A <br />8. FOUNDATION INFORMATION ON THIS PAGE IS FOR GRAPHICAL DEPICTION ONLY. REFER TO FOUNDATION PLAN AND SECTIONS FOR FOUNDATION INFORMATION. <br />9. WALL SECTION AT FOUNDATION AND WALL SECTION AT ROOF ARE TYPICAL FOR ONE AND TWO STORY APPLICATIONS. <br />STEP DOWN TIE -BEAM <br />DIST. FROM DOORJAMB <br />/ WINDOW TO BLOCK <br />MIN. SCREW <br />LENGTH <br />DIST. FROM DOORJAMB <br />/ WINDOW TO BLOCK <br />MIN. SCREW <br />LENGTH <br />3/' OR 1%4' <br />PER MANUF. <br />3" <br />5" <br />11/y <br />3 /4 <br />3 7 6 <br />5„ <br />1 5/16 <br />33/4' <br />3 <br />6„ <br />2 %4" <br />33/4" <br />TYPICAL DOOR/WINDOW JAMB TO BLOCK <br />(TYPICAL FOR ALL MASONRY OPENINGS, UNO) - <br />O <br />O <br />N <br />Ln <br />N <br />It <br />O <br />N <br />N <br />M <br />J <br />LL <br />W <br />J <br />J <br />z <br />O <br />W <br />U <br />0 <br />O <br />W <br />F— <br />U) <br />J <br />17] <br />w <br />Q <br />C) <br />z <br />W <br />0 <br />W <br />W <br />O <br />O <br />O <br />0) <br />i <br />i` <br />ll� <br />O <br />z <br />W <br />W <br />W <br />00 <br />W <br />W <br />z <br />z <br />w <br />IY <br />O <br />LL <br />z <br />O <br />H <br />Q <br />O <br />a <br />0 <br />U <br />Cif <br />O <br />J <br />LL <br />a <br />U <br />z <br />0 <br />O <br />J <br />O <br />z <br />w <br />x <br />w <br />d <br />Q <br />x <br />Q <br />00 <br />ILLI <br />O <br />W <br />a <br />W <br />Z) <br />O <br />H <br />F_ <br />ILL <br />} <br />0 <br />O <br />J <br />O <br />z <br />U <br />w <br />F- <br />x <br />w <br />a <br />O <br />U <br />9 <br />0 <br />APEX 0 O <br />U <br />N <br />(Q <br />tds <br />true design studios N <br />9000 REGENCY SQUARE BLVD. <br />SUITE 100, JACKSONVILLE, FL 32211 <br />O <br />3 <br />CA <br />C <br />C3 <br />ulftioffffi, <br />N <br />This item has been electronically <br />signed and sealed by Justin M Lanier, <br />PE on the date and/or time stamp <br />shown using a digital signature. <br />Printed copies of this document are <br />>W�of considered signed and sealed <br />nd the signature must be verified <br />by a 3rd Party Certificate Authority <br />n any electronic copy y <br />W <br />.I z W <br />W <br />LLJ o v) <br />Q <br />>o <br />m <br />Lu <br />o <br />in <br />J <br />w <br />W <br />w <br />W <br />L.L <br />x <br />QLL <br />z <br />O <br />0 <br />F_ <br />z <br />11 <br />LL <br />w <br />Abbott Park Q <br />U <br />LOT 032-02 ❑ <br />w <br />z <br />0 <br />W <br />PROJECT NO: W <br />2021.011078 ❑ <br />LL <br />- O <br />DRAWN: <br />JAR o <br />CHKD: L0 <br />MJP W <br />w <br />J <br />Q <br />U <br />%. �CIN LA <br />CN , c,7 <br />JJ�� �E N S �F9 '., C� <br />�c' z_ <br />No 85166 <br />� r <br />* ; DocuSigned by: <br />❑ <br />.0 ACG�P35 <br />b. <br />�i C? <br />At- <br />Q <br />09-16-2021 0 <br />w <br />REVISIONS: LILI <br />No. Description Date ~ <br />-- w <br />J <br />U <br />----- - U) <br />I- <br />-- O <br />z <br />ST=5 <br />O <br />CMUIMETAL CONNECTOR ENGINEERINGa <br />
The URL can be used to link to this page
Your browser does not support the video tag.