My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
Abbott Park
Zephyrhills
>
Building Department
>
Building Plans
>
Abbott Park
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2025 6:13:07 PM
Creation date
2/24/2025 10:03:47 AM
Metadata
Fields
Template:
Building Plans
Location
Abbott Park
Contractor
D R Horton
Building Plans - Permit #
Unknown
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALL b' SELF -ADHERING <br />MEMBRANE FLASHING OVER <br />TOP, SIDES) AND BOTTOM <br />FLANGES OF NON -MOVABLE <br />FRAME OF THE EXHAUST. <br />SEQUENCE OF FLASHING TO ISE, <br />I. BOTTOM, 2. SIDES. 3. TOP <br />X: VENT CAP 18 TO BE SET IN SEP <br />OF SEALANT AT TOP AND <br />81DEB ONLY. SEALANT 18 TO SE <br />TOOLED 80 AS TO DEFLECT <br />WATER AWAY FROM JOINTS. <br />E-Z BEAD ALL AROUND <br />I <br />� VENT -APPLY SEALANT ALL <br />1 <br />JOINTS AND INTERSECTIONS <br />I <br />APPLY SEALANT AT PER METER OF <br />SACKER ROD <br />NON -MOVABLE FRAME AND STUCCO <br />ON ALL 81DES, V CAULKING • JOINT <br />ALL AROUND <br />R SECTION R703.7 <br />Extador lathing and plaaterlrig <br />BACKER ROD <br />Exterior use of portlend cement plaster <br />shall comply with the application <br />I <br />.X. <br />requirements of ASTM C 926-18b. <br />1- <br />Installation of exterior lathing and framing <br />shall comply with ASTM C 1063-19a, <br />or ASTM 1787. <br />WRS LAYER'(, <br />STUCCO WRAP <br />HOODED VENT <br />. <br />i' THICK, 3 COAT CEMENT <br />PLASTER <br />METAL LATH <br />WRS LAYER 4, FORTIFISER <br />BUILDING PAPER <br />WOOD SHEATHING <br />DRYER <br />VENT (FRAME) <br />r <br />SHEATHING <br />A WAYER4, FORTIFIBER <br />IN6 PAPER <br />uIDOD <br />cGNaTIICTiaN� <br />—METAL LATH <br />a' CMU VINYL CASING DEAD <br />yW RAISED BAND <br />WEEP aCREED <br />b' WDE STRIP SELF <br />ADHESIVE FLASHING, GLEAN <br />MASONRY BEFORE APPLYING <br />Z PLASHING <br />STONE VENEER <br />OVER SCRATCH COAT <br />7 HORIZONTAL WEEP SCREED <br />W/STONE VENEER <br />(FRAME TO BLOCK( <br />LEGEND <br />DRAINAGE PLANE (WRB <br />LAYER •I, STUCCO WRAP) <br />WRB LAYER 02 (FORTIFIBER - • - - • - - <br />BUILDING PAPER) <br />METAL LATH x—x—x—x <br />STUCCO <br />WOOD OR 1/16' ZIP WALL <br />SHEATHING <br />SELF-ADHESIVE FLASHING - — — — - <br />NOTE: <br />METAL LATH: LATH TO BE PER SECTION <br />R-103.1.1 / ASTM C-641-14a, MIN. 2.5 LBS. <br />PER SQ. YARD (UTILITY OR NOMINAL <br />LATH DOES NOT MEET SPECIFICATIONS) <br />FINISH <br />6' SELF ADHESIVE <br />OVER TOP 4 SIDES <br />PREMANUF. DRYER <br />VENT CAP (SET IN <br />CONT. SEALANT) <br />SEALANT <br />TOP 4 SIDES <br />FjB DRYER VENT (BLOCK) <br />BUILDING PAPER <br />OVER 'QUICK <br />FLASH' <br />PIPE THROUGH / <br />WALL <br />I <br />b' SELF ADHESIVE — <br />FLASHING (INSTALL <br />PER MANUF. SPECS.) <br />SUILDING PAPE <br />UNDER 'QUICK FLASI <br />A VENT PENETRATION <br />11 SCALE: NT.B. <br />ELEC. METEF <br />VERIFY LO <br />STUCCO SCRATCH COAT <br />4 1 COAT OF PAINT W/BACK- <br />ROLL PRIOR TO <br />ELEC. METER INSTALLATION <br />`ELEC. METER FIELD <br />VERIFY LOCATION <br />CONSTRUCTION <br />WOOD SHEATHING <br />WRB LAYER 01, <br />STUCCO WRAP <br />WRB LAYER 02, FORTIFIBER <br />BUILDING PAPER <br />j' THICK, 3 COAT CEMENT <br />PLASTER <br />`—K' TO Y*' MID -WALL <br />WEEP SCREED <br />WOOD <br />C"TIOICTION <br />6' SELF-ADHESIVE <br />FLASHING ecru <br />WOOD FRAMED <br />WALL <br />HORIZONTAL WEEP SCREED <br />( FRAME TO FRAME) <br />APPLY STUCCO SCRATCH COAT <br />AND ONE (U LAYER OF PAINT <br />PRIOR TO INSTALLING ELEC. <br />METER <br />CAVITY TO BE FILLED <br />WITH RIGID POLYMERIC <br />ISOCYANOTE-POLY15LEND FOAM <br />-('GREAT STUFF' OR SIMILAR) <br />APPLY A SILICON <br />BASE SEALANT AT POINT <br />THAT ELEC. WIRE PENETRATES <br />PROVIDE STUCCO SCRATCH <br />COAT LARGER THAN THE ELEC. <br />METER CAN OR METER CAN <br />COMBO OR METER CAN AND <br />DISCONNECT <br />O ELECTRICAL CONDUIT <br />PENETRATION <br />CUT OPENING IN <br />APPROVED HOUSEWRAP <br />FOR BOX INSTALLATION <br />WRB LAYER el, <br />STUCCO WRAP <br />WOOD SHEATHING <br />HOUSEWRAP <br />BELOW <br />CUT SUCH THAT <br />NO MEMBRANE <br />ENTERS BOX, <br />APPLY TO FACE <br />EDGE <br />APPLY E-Z BEAD <br />OVER b® MIN <br />GRADE 'D' <br />FELT-PROvIDE <br />SEALANT AT ALL <br />JOINTS AND <br />INTERSECTIONS <br />WOOD SHEATHING <br />,—WRS LAYER -1, <br />STUCCO WRAP <br />1—WRD LAYER -2, FORTIFIBER <br />BUILDING PAPER <br />/—METAL LATH <br />/—I/a' TEXTURED <br />FINISH • WOOD <br />FASTEN TO OD STRZTURAL <br />�WO <br />MEMCER • 1' = MAX <br />N1' TOY/' MID -WALL <br />WCEP SCREED <br />"—b' WIDE STRIP SELF <br />ADHESIVE FLASNING, CLEAN <br />MASONRY BEFORE APPLYING <br />(�4 HORIZONTAL WEEP SCREED <br />(FRAME TO BLOCK) <br />STEP #1 <br />STEP #3 <br />8' <br />WRB LAYER 44, <br />STUCCO WRAP <br />WIRZ LAYER h, <br />STUCCO UIRAP <br />6 APPLY bm MIN <br />ING <br />GRADE '0' FELT <br />® MEMBRANE FLASHING <br />MEMBRANE FLASHING <br />OVER <br />SELF -ADHERING <br />FLASHING OVER <br />APROVED <br />HOUSEWRAP <br />WIRE LAYER 02, FORTIP15ER <br />BUILDING PAPER <br />STEP #4 <br />ELASTOMERIC <br />COATING OVER <br />STUCCO/ G.V. FINISH <br />(SEE TYPICAL WALL <br />SECTION) <br />'FETAL LATH <br />STEP S STEP #6 <br />OELECTRICAL RECEPTACLE <br />1441 N. RONALD REAGAN BLVD. <br />LONGWOOD, FL32750 <br />PH: 407-774-6078 <br />FAX: 407-7744078 <br />www.abdesigngroup.com <br />AA #: 0003325 <br />km <br />6 <br />io <br />d><Jm At L01! <br />ABBOTT PARK <br />LOT #24 <br />BLK. #11 <br />PMJZCT# <br />04181.000-2 112 <br />uoa� <br />4EBB <br />"1828-CALI" <br />OARAGS OWWO: <br />RIGHT <br />PALM <br />WALL <br />ASSEMBLY <br />DETAILS <br />160 EXP. C <br />
The URL can be used to link to this page
Your browser does not support the video tag.