My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2871 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2871 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 4:52:46 PM
Creation date
2/25/2025 9:35:38 AM
Metadata
Fields
Template:
Building Plans
Street #
2871
Location
Lytton Hall Dr
Contractor
Hidden River
Building Plans - Permit #
863
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SIMPSON HGAMV <br />W/ <br />(4)1/4"x1 1/2" SDS <br />SCREWS <br />TO BLOCKING & (� <br />1/4"X2 3/4" <br />TITEN TO CMU <br />SEE STRUCTURAL NOTES AND TOENAIL W/ (2) 16d NAILS BACKNAIL W/ (2) 16d NAILS SIMPSON H10A w/ (18) <br />NAILING SCHEDULE FOR <br />SHEATHING DETAIL 2"x4" OUTLOOKER7 SEE STRUCTURAL NOTES AND 10d x 1 12" AT EA. <br />TOP CHORD @ 24" O.C. SNAILING HEATHING DETAIL <br />FOR OUTLOOKER <br />BACKNAIL w/ (2)16d NAILS <br />2"x4" SEE STRUCTURAL NOTES — <br />OUTLOOKER AND NAILING SCHEDULE <br />@ 24" O.C. FOR SHEATHING DETAIL <br />BLOCKING FOR <br />FIRST FOUR <br />ROWS OF <br />45' ± <br />24 MAX. <br />TOP CORD BLOCKING <br />45°± <br />2X4 CONT"L" BRACE <br />TRUSSES @ <br />SIMPSON H1OA w/ (18) <br />FOR FIRST FOUR <br />FASTENED W/ (2)1 Od 3" <br />EDGES OF 2x4 CROS 3 BRACE <br />10d x 1 12" @ EA. <br />ROWS OF TRUSSES @ <br />AT 24" 0/C. CMID HEIGHT <br />SHEATHING APPROX. 8" FROM <br />OUTLOOKER <br />EDGES OF <br />TYPICAL @ RIDGE FASTENED AT <br />"L" BRACE TO EXTEND <br />SHEATHING TYP. <br />2X4 KICKER <br />2x8 SYP#2 "L" BRACE TO <br />EXTEND AT LEAST 90% OF <br />48" O.C. EACH JOINT W/ (3) 10d <br />MAX. & (2)10d TOE NAILS @ <br />AT LEAST 90% OF WEB <br />2x4 CROSS BRACE <br />@ 8'-0" 0/C. <br />WEB LENGTH & NOTCH AT <br />EA. END @ 48" O.C. <br />LENGTH (SEE TABLE) <br />APPROX. 8" FROM <br />BOTTOM CHORD (SEE TABLE) <br />2x6 P.T. <br />GABLE TRUSS <br />RIDGE FASTENED AT <br />SIMPSON H2.5A w/ (10) 8d <br />SILL <br />1/2" CDX PLYWOOD OR <br />EACH JOINT W/ (2) 10d <br />FROM LEDGER TO <br />' <br />7/16" OSB SHEATHING <br />& (2)1 Od TOE NAILS @ <br />BLOCKING <br />ATTACHED W/ 10d <br />EA. END <br />NAILS @ 6" O.C. EDGES <br />GYPSUM WALL BOARD <br />GABLE TRUSS <br />AND 12" O.C. FIELD <br />2"x4" PANEL BLOCKING @ 48" O.C. FOR THE FIRST <br />1OdX3" 3" O/C <br />@ <br />(4) ROWS OF TRUSSES FROM EA. END TYP. BOTTOM <br />1/2" CDX PLYWOOD OR 7/16" <br />THROUGH CHORD <br />CORD ATTACHED W/ (2)16d TOENAILS <br />OSB SHEATHING ATTACHED <br />1 Od NAILS 6" O.C. <br />A <br />w/ @ <br />INTO 74" P.T. PLATE <br />2"x4" LEDGER (MATCH BOTTOM CHORD <br />EDGES AND 12" O.C. FIELD <br />2x4 "T" ON TOP OF PANEL BLO( <br />WEEP SCREED <br />SLOPE OF ADJACENT SCISSOR TRUSS) <br />FASTEN WITH 10dx3" @ 4" O/C SPACED <br />INSTALLED PER MANUF. <br />2"x6" P.T. SILL <br />NOTCH "L" BRACE HERE <br />48" O.C. <br />MOISTURE BARRIER <br />518" x 10" "J" BOLT @ 48" O.C. <br />WEEP SCREED <br />5/8"x 10" "J" BOLT @ 32" O.C. MINIMUM 6" FROM <br />SIMPSON HETA20 w/ (8)1Odxl 1/2" NAILS AT 6'-0" <br />INSTALLED PER MANUF. <br />PLATE SPLICES W/ 3/16"x2" 0 PLATE WASHER <br />SIMPSON HETA20 w/ (8) <br />O.C. MAX w/ MIN. 4" EMBEDMENT IN KO BLOCK - <br />MOISTURE BARRIER <br />10dx1 1/2" NAILS AT EA. <br />ALTERNATE SIMPSON MSTAM24 w/ (7)1 Od NAILS <br />NOTE: IF EMBEDDED <br />TRUSS VERTICAL WEB (24" <br />& (4) 1/4"x2 1/4" TITEN @ 4'-0" O/C ALIGNED WITH <br />STRAP MISSED VERTICAL <br />SECTION <br />O.C. MAX) w/ MIN. 4" <br />EMBEDMENT IN KO BLOCK <br />GABLE WEB <br />SECTION <br />2 <br />WEB, USE MSTAM36 w/ (7) <br />1Od NAILS & (4)1/4"x2 1/4" <br />SCALE: N.T.S. <br />S5 <br />SCALE: N.T.S. <br />Srj <br />TITEN ON OUTSIDE <br />BACKNAIL W/ (2) <br />16d NAILS <br />REFER TO DETAIL J <br />_ <br />r <br />SEE STRUCTURAL <br />ON SHEET S5 FOR <br />co <br />Frr <br />NOTES AND NAILING <br />X-BRACING, AND TOP <br />r <br />N <br />SCHEDULE FOR <br />CHORD BLOCKING <br />60 00 <br />SHEATHING DETAIL <br />INFORMATION <br />1 1 1/ <br />2"x4" CROSS BRACE <br />WOOD TRUSSES <br />co - z <br />00 <br />APPROX. 8" FROM <br />RIDGE FASTENED AT <br />2X4 RAT RUN BRACING <br />1 121 1 2 <br />EACH JOINT W/ (2) <br />AT 24" O.C. ON TOP OF <br />10d & (2)10d TOE <br />BOTT. CHORD FOR 4 <br />NAILS @ EA. END <br />TRUSS SPANS <br />ATTACHED W/ 2 - 16d <br />2x4 PANEL BLOCKING <br />AT EA. TRUSS JOINT <br />(2) 2 x 4' LAMINATIONS W/ (1) ROW (3) 2" x 4" LAMINATIONS W/ (1) ROW (3) 2" x 6" LAMINATIONS W/ (2) ROWS OF <br />@ 48" O/C FOR THE <br />FIRST (4) ROWS OF <br />2x4 BLOCKING 24 <br />@" <br />OF STAGGERED 10d COMMON WIRE NAILS OF STAGGERED 30d COMMON WIRE NAILS STAGGERED 30d COMMON WIRE NAILS <br />TRUSSES FROM EA. <br />O/C w/ (2)16d <br />(D = 0.148", L = 3") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL (D = 0.207", L = 41/2") OR EQUAL <br />END TYP. TOP & <br />TOENAILS @ EA. END <br />NOTES: <br />BOTTOM ATTACHED <br />1) ADJACENT NAILS ARE DRIVEN FROM OPPOSITE SIDES 4) FOR 4-PLY, PROVIDE 1/4" DIA. x 51/2" LAG SCREWS OR EQUAL <br />w/ (2)16d TOENAILS <br />MASONRY WALL <br />OF THE COLUMN (SPACE AS SHOWN FOR 3-PLY) <br />ARCHITECTURAL FINISH <br />SIMPSON H1OA w/ (18) SIMPSON SP4 w/ (6)1 Od x <br />1Od x 1 12" AT EA. 1 12" AT EA STUD (USE <br />BACKNAIL w/ (2)16d NAILS <br />OUTLOOKER SP6 FOR 2x6 WALL, USE <br />SEE STRUCTURAL NOTES — <br />SP8 FOR 2x8 WALL) <br />AND NAILING SCHEDULE <br />FOR SHEATHING DETAIL <br />41 1-1 <br />2x4 OUTLOOKER @ 24" <br />O.C. (OPTIONAL - SEE <br />TOP CORD BLOCKING <br />FOR FIRST FOUR ROWS <br />4„ MAX <br />ELEVATIONS) <br />OF TRUSSES @ EDGES <br />OF SHEATHING TYPICAL <br />DOUBLE TOP PLATE <br />2"x4" CROSS BRACE <br />2x4 CROSS BRACE APPROX. 8" <br />APPROX. 8" FROM <br />FROM RIDGE FASTENED AT <br />RIDGE FASTENED AT <br />EACH JOINT W/ (2) 10d & (2) 10d <br />EACH JOINT W/ (2) <br />TOE NAILS @ EA. END <br />10d & (2)10d TOE <br />2x FRAME WALL (SEE WALL <br />NAILS @ EA. END <br />SECTION FOR SIZE & SPACING) <br />2x4 PANEL BLOCKING <br />1l2" CDX PLYWOOD OR 7/16" <br />@ 48" O/C FOR THE <br />OSB SHEATHING ATTACHED <br />FIRST (4) ROWS OF <br />W/ 10d NAILS @ 6" O.C. EDGES <br />TRUSSES FROM EA. <br />AND 12" Q.C. FIELD <br />END TYP. TOP & <br />(2) 16d NAILS <br />2x BLOCKING <br />BOTTOM ATTACHED <br />W/ (2) 16d TOENAILS <br />2x4 PANEL BLOCKING @ 48" <br />O.C. FOR THE FIRST (4) <br />ROWS OF TRUSSES FROM <br />2 4 "T" ON TOP OF PANEL <br />SIMPSON H1OA w/ (18) <br />1Od x 1 12" AT EA.� <br />OUTLOOKER <br />(2)16d <br />NAILS <br />2x4 OUTLOOKER <br />@ 24" OfC <br />TOP CORD <br />BLOCKING FOR <br />FIRST FOUR ROWS <br />OF TRUSSES @ <br />" MAX. EDGES OF <br />SHEATHING TYP. <br />-"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />-GABLE TRUSS <br />—1/2" CDX PLYWOOD OR <br />7/16" OSB SHEATHING <br />ATTACHED w/ 10d NAILS <br />@ 6" O.C. EDGES AND 12" <br />O.C. FIELD <br />-2x4 "T" ON TOP OF PANEL <br />3 BLOCKING, FASTEN WITH <br />1Odx3" @ 4" O/C <br />x SIMPSON HGAI OKT w/ (4) 1/4"xl 1/2" <br />EA. END TYP. TOP & BLOCKING, FASTEN WITH SDS SCREWS TO TRUSS & (4)1f4"x3" <br />BOTTOM ATTACHED w/ (2) 1 Odx3" @ 4" O/C SDS SCREWS TO PLATES AT 36" O.C. SIMPSON SP2 w/ (12)1 Od <br />16d TOENAILS 2x4 LEDGER MATCH BOTTOM DBL. TOP PLATE ( NAILS AT EACH STUD <br />CHORD SLOPE OF ADJACENT STUD WALL SEE TYP. SEC.) <br />TRUSS) <br />SECTION 3 SECTION 4 <br />SCALE: N.T.S. S5 SCALE: N.T.S. 15 <br />SIMPSON H10A w/ (18) <br />1 Od x 1 12" AT EA. 2x4 OUTLOOKER <br />OUTLOOKER @ 24"NX O/C <br />TOP CORD <br />BLOCKING FOR <br />FIRST FOUR ROWS <br />OF TRUSSES @ <br />24" MAX. EDGES OF <br />SHEATHING TYP. <br />"L" BRACE TO EXTEND <br />AT LEAST 90% OF WEB <br />LENGTH (SEE TABLE) <br />GABLE TRUSS <br />1/2" CDX PLYWOOD OR 7/16" <br />• (2) 16d NAILS OSB SHEATHING ATTACHED <br />W/ 10d NAILS @ 6" O.C. <br />ED AND 12" O.C. FIELD <br />JACK TRUSS <br />SEE PLAN FOR <br />CONNECTION <br />2) ALL NAILS PENETRATE AT LEAST 314 OF THE THICKNESS 5) FOR 5-PLY, PROVIDE 1/4 DIA. x 7 LAG SCREWS OR EQUAL 2x4 "T" ON TOP OF PANEL-' LL <br />OF THE LAST LAMINATION (SPACE AS SHOWN FOR 3-PLY) BLOCKING, FASTEN WITH L 2x4 BLOCKING W/ <br />3) EACH 30d COMMON NAIL MAY BE REPLACED W/ (2)16d 6) REFER TO NDS SECTION 15.3 FOR ADDITIONAL INFORMATION 1Odx3" @ 4" O/C (2)12d TOENAILS <br />EXT. WALL CONN. COMMON NAILS. (ONE INTO EACH OUTSIDE FACE OF <br />NON -LOAD BEARING LOCATION B.U.C. SAME NUMBER OF ROWS SAME SPACING <br />D ) SECTION <br />SEETYP.WALLSECTIONFOR SCALE:3/4"=1'-o'I S5 TYPICAL NAILING SCHEDULES FOR BUILT-UP COLUMNS 8 K, 9 <br />ADDITIONAL INFORMATION. SCALE: N.T.S. S5 SCALE: N.T.S. S5 <br />2"x4" OUTLOOKER @ 24" O.C. W/ (2)1 Od PER JOINT <br />1INIMUM 2x <br />'ROSS BRACING _ <br />SEE PLAN FOR <br />OCATIONS) 10dx3" O/C <br />TOENAIL 6" O/C <br />W/ (2)16d TYPICAL <br />(2)16d PER NAILS <br />JOINT <br />�- CONTINUOUS BOTTOM CORD BRACING 2"x4" MIN. SEE M/S5 <br />CROSS BRACING DETAIL ri <br />12 <br />6.9 MAX. <br />SCALE: N.T.S. <br />ALTERNATE NON -DROP <br />GABLE END DETAIL <br />SCALE: N.T.S. <br />ri <br />GABLE TRUSS <br />"L" BRACE W/ 10d @ 4" O.C. <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />\-CONT. BEARING <br />GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION SCALE: N.T.S. <br />PRE-ENGINEERED <br />WOOD TRUSSES <br />OVERLAP TRUSS BRACING <br />AT LEAST TWO TRUSS SPACES 6" OVERLAP <br />`MINIMUM (2) 16d PER JOINT \-MINIMUM 2x4 TRUSS BRACING <br />TRUSS BRACING OVERLAP DETAIL M <br />SCALE: N.T.S. Srj <br />"L" BRACE W/ 10d @ 4" O/C <br />(SEE SCHEDULE FOR SIZE <br />AND LOCATION) <br />8d @ 6"O/C 2 x 4 BLOCKING w/ (2)1 Od <br />WOOD TRUSSES TOE NAILS AT EACH END @ <br />24" O/C (TYP) <br />BRACING w/ (3)10d x 3" AT <br />• EACH CONN. @ 24" O/C <br />SIMPSON HGAM10KTAw/ (4) MOISTURE BARRIER <br />1/4"x1 1/2" SDS SCREWS TO <br />BLOCKING & (4)1/4"X2 3/4" BOND BEAM <br />TITEN TO CMU <br />Pl:� MASONRY WALL <br />ARCHITECTURAL FINISH <br />EXT. WALL CONN. NON -LOAD <br />BEARING LOCATIO (UNEVEN CLG.) <br />SEE TYP. WALL SECTION FOR <br />ADDITIONAL INFORMATION. <br />SCALE: N.T.S. <br />"L" BRACING REQUIREMENTS <br />STUD <br />SPACING <br />NO <br />"L" BRACE <br />(1) 2"x4" (U.N.O.) <br />L BRACE <br />2"x6" (U.N.O.) <br />L BRACE <br />24" <br />0'0" - T-0" <br />T-0" - 6'-0" <br />6'-0" & GREATER <br />SCISSOR GABLE - (1) 2"x8" #2 S.P.F. @ EACH VERTICAL AND <br />(2) 2"x8" FULL HEIGHT @ DIAPHRAGM BLOCKING <br />NOTE: <br />1) "L" BRACE MUST EXTEND AT LEAST 90% OF WEB LENGTH EXCEPT, SCISSOR GABLE WHICH REQUIRES <br />BRACE TO EXTEND FULL HEIGHT OF GABLE. <br />2) "L" BRACE TO BE FASTENED TO GABLE STUD WITH 10dx3" NAILS @ 4" 0/C. <br />3) SEE 6/S5 FOR MORE INFO. <br />SIMPSON HGA10KT w/ (4) 1/4"x1 1/2" SDS <br />—VI.JIV I . DCFIRIIVl7 <br />GABLE END BRACING DETAIL SCALE:3/4"=1'-0" <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />SIMPSON SP2 W/ (12) <br />10d NAILS AT EACH <br />STUD <br />END JACK <br />1 V-0" MAX. <br />q0'F <br />o <br />CORNERJACK <br />U <br />1 <br />U <br />, <br />Q <br />LU <br />Z <br />O <br />U <br />HIP FRAMING REFERENCE PLAN <br />2x4 BLOCKING 2x4 "T" BLOCKING <br />@ 48" O.C. 16d NAIL <br />"L" BRACE <br />ATTACHED W/ <br />1Od NAILS @ 4" <br />O.C. TYPICAL <br />GABLE TRUSS WEB <br />DOUBLE "L" BRACING DETAIL 5 <br />SCALE: N.T.S. S5 <br />2x4 "T" BLOCKING <br />2x4 BLOCKING @ <br />48" O.C. <br />"L" BRACE ATTACHED 16d NAIL <br />W/ 1Od NAILS @ 4" 0.C� <br />TYPICAL <br />GABLE TRUSS WEB <br />SINGLE "L" BRACING DETAIL/ 6 <br />SCALE: N.T.S. <br />DIAPHRAGM <br />BLOCKING @ <br />48" O/C GABLE TRUSS <br />TRUSS VERTICAL <br />(2) 2"x8" "L" BRACE J <br />FASTENED WITH (3) <br />16d PER SIDE <br />SCISSOR GABLE "T" BRACE <br />AS PER HIB 91 SCALE: N.T.S. S5 <br />20'-0" MAX 20'-0" MAX <br />"X" BRACE SEE DET. J/S5 , CONTINUOUS BOTTOM CHORD BRACING 2X4 MIN. <br />� <br />---- <br />---- <br />---- <br />---- <br />LU <br />4 <br />o <br />O <br />4 <br />Z O <br />W d <br />W <br />m o <br />0 ' <br />o <br />, <br />� <br />0 <br />d <br />W <br />Q <br />o <br />� <br />�, <br />CDQ <br />X <br />I <br />o <br />� <br />W <br />NOTE: <br />1) SEE TRUSS MANUFACTURER'S TRUSS ENGINEERING <br />CUT SHEETS FOR ADDITIONAL PERMANENT BRACING <br />THAT MY BE REQUIRED <br />2) "T" BRACING MAY BE USED IN PLACE OF PERMANENT <br />BRACING PROVIDED IT EXTENDS OVER AT LEAST 90% OF THE WEB. <br />REQUIRED MINIMUM PERMANENT TRUSS BRACING PLAN <br />AS PER BCSI 1-13 <br />SCISSOR TRUSS <br />SCISSOR TRUSS <br />W/ DROP CEILING BRACING DETAIL <br />/TOP & BOTTOM CHORD <br />GABLE END BRACING @ <br />4'-0" O.C. MAX. FOR <br />FIRST (4) ROWS OF TRUSSES <br />SCALE: N.T.S. <br />2X4 BRACING @ 48" O.C. CONTINUOUS TO <br />FIXED LOCATION ATTACHED W/ (2)1 Od AT <br />EA. TRUSS (NOTE: BRACING MAY BE <br />PLACED ON EITHER TOP OR BOTTOM OF <br />THE BOTTOM CORD) <br />COSMETIC DROP CEILING FRAMING <br />MEAN ROOF HEIGHT UP TO 30'-0" SCALE: NTS <br />SEE STRUCTURAL NOTES FOR WIND SPEED SPECIFICATION <br />WOOD FRAMED GABLE END BRACING DETAIL <br />MEAN WALL HEIGHT UP TO 30'-0" - SEE STRUCTURAL NOTES SCALE: N.T.S. <br />FOR WIND SPEED SPECIFICATION <br />�i��gEtliitll9tdfl,!/�� <br />c r <br />1` i •�r 1�1 J l • 4, <br />• <br />\� <br />F0-111 <br />5� �4 • <br />�. <br />ca <br />FL <br />�f%.�QF <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions <br />of the drawing pages bearing <br />Engineer's signature and seal. <br />W <br />4/ <br />M <br />� 8 co c0 W <br />N W <br />(0 O <br />C # m1 LL <br />W <br />di <br />n r-- d <br />M <br />'i <br />(6�k ' IW <br />LU LU <br />W LL <br />zJ', <br />�o � <br />L m o� M, RE O <br />W <br />m <br />og'rn ¢W CO a <br />z <br />0 <br />co CIJ Z <br />coQ O � <br />a`n <br />z <br />N Q U H <br />° V ❑❑❑ <br />W <br />63 <br />t2 <br />Z N M <br />o <br />z <br />N <br />s� <br />Q v <br />drumm <br />llL IV <br />N <br />N <br />z o <br />C: <br />0 <br />a--+ <br />u, <br />Q A <br />U <br />_ <br />0 <br />1zN <br />W s <br />U w <br />(a <br />v <br />LU <br />~ <br />J <br />i— — E <br />= s <br />I <br />=ems <br />w <br />10 us <br />c (n M <br />N o, <br />■ <br />®Q <br />s m <br />o <br />MC <br />z <br />o <br />w <br />Z <br />Z4 <br />Q E <br />2 <br />wO <br />Z <br />} N <br />Z <br />Z® <br />oa <br />Ca <br />tCa r <br />O E <br />KO <br />oa <br />ao <br />�00 <br />0< <br />az <br />N <br />a0 <br />¢ <br />rw <br />L <br />cj c <br />m 0 <br />a <br />oLL <br />CI) J <br />�� <br />�Z <br />N <br />0 <br />Q <br />rl <br />.F <br />CTj <br />ao <br />�� <br />CD <br />q¢ <br />< <br />�3 <br />>° <br />o <br />O <br />rl <br />w <br />Z. <br />ar <br />� 3 <br />�N <br />0 <br />= <br />J <br />co <br />W <br />m <br />U <br />L <br />L <br />A \ m <br />T <br />s— <br />■ <br />>' N <br />JLO <br />T <br />T <br />r <br />ni <br />m <br />w fto <br />T <br />N T <br />v; 0) <br />o <br />Z <br />Z <br />E 0 <br />c <br />E <br />v N <br />JOB <br />NO : <br />20-6576 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />S5 <br />: <br />
The URL can be used to link to this page
Your browser does not support the video tag.