My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
2871 Lytton Hall Dr
Zephyrhills
>
Building Department
>
Building Plans
>
2871 Lytton Hall Dr
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/3/2025 4:52:46 PM
Creation date
2/25/2025 9:35:38 AM
Metadata
Fields
Template:
Building Plans
Street #
2871
Location
Lytton Hall Dr
Contractor
Hidden River
Building Plans - Permit #
863
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
23
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
> <br />J9 <br />ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />POWER CO. FEED <br />INTERSYSTEM <br />BONDING <br />TERMINATION PER <br />NEC 14, 250.94 J <br />200A INDOOR PANEL <br />CENTER <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />apper to lights & outlets <br />apper to 20 amp ckts <br />copper to WH <br />copper to Dryer <br />t Alu <br />GENERAL ELECTRICAL NOTES: Typical 150-200 Amp Electrical Riser Diagram (Updated 7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />FF <br />DUPLEX OUTLET ABOVE COUNTER <br />I <br />WEATHERPROOF DUPLEX OUTLET <br />GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />$ <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />OQ <br />RECESSED LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />WP GFI DISC. <br />H.B. <br />DEDICATED RECEPTACLE <br />FOR MICROWAVE RANGE <br />Unnn n17171 c+nrrr+c <br />Q <br />EXHAUST FAN <br />-- <br />j <br />W.H. VERIFY LOCATION <br />GFI <br />_ _ _ _ _ <br />_ _ _ _ _ <br />J <br />ELECTRICAL PANEL <br />rot <br />EXHAUST FAN/LIGHT COMBINATION <br />h_Q <br />L4 <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />RECEPT. ill <br />CH <br />CHIMES (OPTIONAL) <br />FOR ALARM VERIFY METER <br />Pt3 <br />PUSH BUTTON SWITCH (OPTIONAL) <br />SYSTEM LOCATION WITH <br />BUILDER <br />I [D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />0 <br />TELEVISION (OPTIONAL) <br />©2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />n_ <br />ELECTRIC PANEL <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />L T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />ENTRY <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4"=V-0" <br />0 <br />N <br />O <br />CV <br />rn <br />0 <br />To the best of the Engineers knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and <br />seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineers signature and seal. <br />UL) <br />r <br />Q <br />co p <br />U <br />(00 <br />o r- <br />N N ik <br />C <br />N N <br />2r- Cc <br />� N <br />un W LJL <br />H <br />T <br />Ui r „O <br />M M <br />J W <br />LL —1 a <br />H <br />V <br />a j <br />a U. W <br />W <br />W a <br />Z <br />C6�L=_ <br />caC <br />0=o <br />G: <br />@ N (p <br />m m m <br />W <br />W <br />o <br />rn <br />¢ : ¢ <br />a <br />J DOD <br />O <br />N Cl) <br />0 en <br />0 O <br />= <br />Q <br />O U <br />El 0' 0 <br />W <br />z N <br />o g <br />N <br />z o � <br />� <br /><c <br />U) <br />J <br />a <br />M <br />yQ)j <br />o.2 <br />6 <br />W <br />Q 9 <br />V <br />�po <br />0 <br />W O <br />to <br />y <br />Rig <br />r— rn <br />U <br />W J <br />r— — E <br />m $ <br />¢ <br />z <br />S <br />I <br />0 <br />c o <br />®0 <br />Q W 0 <br />N O <br />�o <br />w <br />M <br />M <br />Z <br />o S <br />z <br />Q E <br />E <br />w= <br />�s <br />Z® <br />oa <br />o <br />to <br />O <br />X U <br />¢Q <br />¢z <br />Qo <br />O� <br />wz <br />CV t <br />o <br />t <br />ru <br />� <br />r� CU <br />N <br />o <br />ZK <br />ty <br />to J <br />m <br />a <br />Q W <br />z <br />a`Ni 3 <br />Q <br />8� <br />w� <br />go <br />a z <br />nw <br />W <br />T <br />U <br />E <br />�o <br />= <br />ti <br />o <br />w <br />�o <br />O <br />z< <br />I <br />UU a rz- <br />�N <br />0 <br />= <br />> d' <br />L <br />1 <br />0 <br />� <br />N <br />0 <br />03 <br />ICU <br />O <br />.� <br />� N <br />r <br />CDT <br />n N <br />T <br />r <br />Ew <br />ca <br />T <br />N <br />i6 0 <br />o <br />Z <br />Z <br />E O <br />E0 <br />U J <br />Q 0 <br />c <br />CD <br />J <br />JOB <br />NO: <br />20-6576 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />ntsWnn wnrnreesmrwwlr��s�..t� <br />
The URL can be used to link to this page
Your browser does not support the video tag.