Laserfiche WebLink
3 TAB SHINGLES. ROOF <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS ___1_1 <br />12 <br />5 F/ <br />3 TAB SHINGLES. ROOF _ <br />INSTALLED AS PER MANUF. <br />SPECIFICATIONS <br />18' RIDGE VENT <br />OFFRIDGE VENT�,4' OFFRIDGE <br />T 16'-7" � 6'-0 <br />---------- T.O.M. <br />7P41'-0" <br />------- HDRI <br />o <br />00 cD <br />co <br />----------------------------------- F.FL. <br />REAR ELEVATION - B1. <br />4' RIDGE VENT <br />12 12 <br />(% <br />T.O.M. — <br />HDR HGT. <br />1'-0" <br />TEXTURED <br />2'-0" 01 <br />o CEMENTITIOUS TEXTURED <br />9 _ FINISH ON C.M.U. <br />iio CEMENTITIOUS <br />co (TYP.) FINISH ON C.M.U. <br />(TYP.) <br />F.FL.- — — — — — — — — — --------------------------------------------------------------------------------------- <br />RIGHT ELEVATION - B1 <br />SCALE: 1 /4"=V-0" <br />General Notes <br />ROOF CRITERIA: <br />• 12" OVERHANG U.N.O. <br />• PLUMB CUT FASCIA ROOF <br />• PITCH PER ELEVATION <br />**G.C. VERIFY ROOF PITCH** <br />ROOF PITCH VARIES PER SUBDIVISIONS IT IS THE <br />CONTRACTORS RESPONSIBILITY TO VERIFY <br />ROOF SLOPE REQUIREMENTS WITH TRUSS <br />MANUFACTURER. <br />**ELECTRICAL SPECIFICATION NOTES** <br />ELECTRICAL CONTRACTOR MUST VERIFY WITH <br />THE SPECIFICATIONS FOR THE TYPE OF FIXTURE <br />TO BE USED. LIGHT FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />Exterior Covering <br />R703.7 Exterior plaster. <br />Installation of these materials shall be in compliance with ASTM C <br />926 and ASTM C 1063. <br />R703.7.1 Lath. <br />All Lath and lath attachments shall be of corrosion -resistant <br />materials. Attached per ASTM C 1063. <br />R703.7.2 Plaster. <br />Plastering w/ portiand cement plaster shall be not less than three <br />coats when applied over metal lath or wire lath and shall be not <br />less than two coats when applied over masonry, concrete. <br />R703.7.3 Water -Resistive Barriers. <br />Water -resistive barriers shall be installed where cement plaster <br />(stucco) is to be applied over wood -based sheathing, shall include <br />a water -resistive vapor -permeable barrier. The individual layers <br />shall be installed independently such that each layer provides a <br />separate continuous plane and any flashing intended to drain to <br />the water -resistive barrier is directed between the layers. The <br />barriers shall consist of one of the following. <br />1. Two layers of an approved water resistant barrier material in <br />accordance with R703.2. <br />2. One layer of an approved water -resistive barrier (paper <br />backed stucco lath) over an approved synthetic house wrap. <br />R703.4 Flashing. <br />Approved corrosion -resistant flashing shall be applied <br />shingle -fashion in a manner to prevent entry of water into the wall <br />cavity or penetration of water to the building structural framing <br />components. Flashing shall be installed at the following locations. <br />• Exterior window/door openings. <br />• Intersection of chimneys or other masonry constructions with <br />frame walls. <br />• Under and at the ends of masonry, wood or metal copings <br />and sills. <br />• Continuously above all projecting wood trim. <br />• Where exterior porches, decks or stairs attach to a wall or <br />floor assembly of wood -frame construction. <br />• At wall and roof intersections <br />• At Built-in gutters. <br />Coastal Flashings <br />All flashing material for coastal locations (ex: within 3,000 feet of the <br />ocean) shall be corrosion resistant material (ex: zinc and/or stainless <br />steel) and shall be selected for compatibility with adjacent wood <br />preservatives per the manufacturer's recommendations. <br /><O �J� <br />�• OF;�Io <br />ES <br />1 <br />/egp�(tijlr3Z <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained within these <br />drawings comply with the 2017 <br />Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />N <br />W <br />EE co p°�po <br />8 N N it <br />O <br />A <br />J <br />N <br />" <br />fA <br />rn�; 9,J-i <br />N � LL a <br />� w <br />Q <br />UJ <br />�mM w UJ <br />roLLiL a a <br />J -o — Z O <br />m c M O Of f <br />y= M M <br />tWll <br />Z <br />IL <br />o o_ <br />00 0 <br />rnIL <br />N m Z U 0 <br />z <br />J <br />°U ❑❑❑ <br />W <br />z N <br />o g <br />co <br />Z <br />¢N <br />� O Q <br />Q i <br />J <br />d N <br />n <br />N <br />z <br />C <br />0 <br />11 <br />4 <br />w � <br />0wo <br />�.. <br />all <br />U <br />� <br />— J E <br />— g <br />oI <br />xi <br />Zw <br />ai <br />rn <br />to, <br />N <br />44 <br />Oco <br />w <br />Z <br />M <br />Zo <br />7d <br />LJL <br />Q E <br />zo <br />oo <br />g <br />}R <br />Z� <br />Z® <br />COO <br />U <br />O E <br />0 <br />a0 <br />O <br />a= <br />Z <br />O <br />t <br />ao <br />¢o <br />wz <br />wg <br />rp <br />C <br />z <br />Y <br />U <br />m O <br />'0 LL <br />z <br />ZN� <br />u� J <br />N <br />a' <br />lolog <br />Qw <br />�z <br />z <br />az <br />N <br />U)3 <br />az <br />=3 <br />o <br />O <br />w� <br />>O <br />a <br />d' <br />z < <br />O <br />C � <br />i <br />�M <br />hi <br />o� <br />m <br />L <br />f6 <br />00 <br />O <br />CL <br />C o <br />F_ <br />�^I `` mcc <br />W <br />2 <br />O N <br />J <br />T <br />.T 1 OO <br />M 04 <br />12 <br />iti <br />Y <br />N <br />o <br />E <br />T <br />E Q <br />N <br />0 <br />Z <br />cc <br />g <br />a <br />E <br />U ° <br />Q co <br />c <br />JOB <br />NO: <br />20-4940 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />3.2 <br />