Laserfiche WebLink
ELECTRICAL SPECIFICATION <br />NOTES: <br />ELECTRICAL CONTRACTOR <br />MUST VERIFY WITH THE <br />SPECIFICATIONS FOR THE TYPE <br />OF FIXTURE TO BE USED. LIGHT <br />FIXTURES SHOWN ARE FOR <br />LOCATION PURPOSES. <br />200A INDOOR PANEL <br />CENTER <br />#14 copper to lights & outlets <br />1 <br />200 #12 copper to 20 amp ckts <br />00 AMP <br />#10-2 copper to WH <br />#10-3 copper to Dryer <br />MAIN <br />'y- <br />O <br />200 amp <br />Y2/0or4/0SERAJu <br />150 amp <br />Disconnect <br />POWER CO. FEED <br />INTERSYSTEM <br />4 Bare Cu Ground <br />BONDING <br />#4 GROUNDING WIRE <br />TERMINATION PER <br />WITH CODE APPROVED <br />NEC 14, 250.94 <br />CLAMP PER 250.50 AND <br />250.52 OF THE 2014 NEC. <br />GENERAL ELECTRICAL NOTES. Typical 150-200 Amp Electrical Riser Diagram (Updated7-1-14) <br />NOTE: ELECTRICAL MATERIAL AND INSTALLATIONS SHALL COMPLY WITH APPLICABLE <br />Notes: unless otherwise noted, PROVISIONS OF THE NFPA 70 - 2014, LOCAL CODES AND THE LOCAL POWER CO. <br />1. Electrical outlet heights as measured from finished floor to centered line of the box to be: 16" AFF <br />(general). In a Flood Zone, all electrical equipment to be at or above DFE. <br />kitchen 44" AFF <br />bathroom 39" AFF <br />laundry room 36" AFF <br />exterior waterproof 12" AFF <br />garage general purpose 44" AFF <br />range 2" AFF <br />2. All trim plates & devices to be ganged, where possible. <br />3. Electrical switches to be at 42" centerline above finished floor. <br />4. Electrical plan is intended for bid purposes only. All work shall be done in strict accordance with the <br />national electric code, latest edition, by a licensed electrical contractor who shall be responsible for the <br />installation & sizing of all electrical, wiring & accessories. <br />5. Smoke detectors shall be in accordance with R314.1 and listed in accordance with UL 217. <br />6. Provide AFCI's (Arc -Fault Circuit Interrupters) combination type installed to provide protection of the <br />branch circuits in all dwelling units per NFPA 70 and the 2014 NEC. <br />7. Provide Tamper Resistant Receptacles as required by the 2014 NEC. <br />8. Carbon Monoxide Protection: carbon monoxide alarms or detectors shall be installed in all dwelling <br />units in accordance with FBC R315 and NFPA 70. Such devices shall be listed by the appropriate <br />standard, either ANSI/UL 2034, standard for single and multiple station co alarms or UL 2075, gas and <br />vapor detector sensor, according to the installation. <br />9. R315.1.2 Combination Alarms: combination smoke/carbon monoxide alarms shall be listed and <br />labeled by a Nationally Recognized Testing Laboratory. <br />10. Keep all smoke detectors minimum of 36" from bathroom doors <br />11. In new construction, smoke detectors shall be hardwired into an A/C electrical power source and <br />shall be equipped with a monitored battery backup. <br />12. Bathroom exhaust fans must vent to the exterior of the building, ventilation to attic space and soffits <br />is not acceptable. <br />13. All doors and windows providing direct access from the home to the pool shall be equipped with an <br />exit alarm complying with UL 2014 that has a minimum sound pressure rating of 85 DBA at 10 feet, and <br />either hardwired or of the plug-in type. The exit alarm shall produce a continuous audible warning <br />when the door or window are opened.. <br />14. Add GFCI protection to receptacles in laundry rooms and utility rooms of dwellings where installed <br />within 6' of the outside edge of a sink. This would include the receptacle installed for a washing <br />machine. Receptacles outlets shall not be required on a wall directly behind a range or sink to fulfill the <br />requirement for an outlet every 24". The width of the sink or range is not to be included in the spacing <br />of the outlets unless the distance from the sink or range is greater the 12" for straight counter tops and <br />18" for sinks and ranges installed in corner counters. <br />ELECTRICAL KEY <br />DUPLEX CONVENIENCE OUTLET <br />PEPP <br />DUPLEX OUTLET ABOVE COUNTER <br />WP <br />WEATHERPROOF DUPLEX OUTLET <br />I&GFI <br />GROUND FAULT INTERRUPTER DUPLEX OUTLET <br />HALF -SWITCHED DUPLEX OUTLET <br />SPECIAL PURPOSE OUTLET <br />DUPLEX OUTLET IN FLOOR <br />220 VOLT OUTLET <br />WALL SWITCH <br />$3 <br />THREE-WAY SWITCH <br />?4 <br />FOUR-WAY SWITCH <br />$R <br />RHEOSTAT SWITCH <br />CEILING MOUNTED LIGHT FIXTURE <br />LED <br />LED CEILING MOUNTED LIGHT FIXTURE <br />WALL MOUNTED LIGHT FIXTURE <br />ORECESSED <br />LIGHT FIXTURE <br />+PC <br />LIGHT FIXTURE WITH PULL CHAIN IN ATTIC ACCESS <br />TRACK LIGHT <br />FLUORESCENT LIGHT FIXTURE <br />O <br />EXHAUST FAN <br />EXHAUST FAN/LIGHT COMBINATION <br />®D <br />ELECTRIC DOOR OPERATOR (OPTIONAL) <br />CH <br />CHIMES (OPTIONAL) <br />lfg <br />PUSH BUTTON SWITCH (OPTIONAL) <br />�D <br />PUSH BUTTON SWITCH - DOOR BELL <br />SD <br />SMOKE DETECTOR <br />CO <br />CARBON MONOXIDE DETECTOR <br />CM <br />SMOKE/CARBON MONOXIDE DETECTOR (COMBO UNIT) <br />a <br />TELEPHONE (OPTIONAL) <br />USB <br />TELEPHONE/USB (OPTIONAL) <br />© <br />TELEVISION (OPTIONAL) <br />© 2 <br />(2) TELEVISION (OPTIONAL) (1)@ STD. HT. & (1)@ 60" A.F.F. <br />O <br />THERMOSTAT <br />ELECTRIC METER <br />ELECTRIC PANEL <br />_ I <br />DISCONNECT SWITCH <br />ROUGH -IN FOR OPT. CEILING FAN <br />CEILING MOUNTED LIGHT FIXTURE W/ ROUGH -IN FOR <br />G T J <br />OPT. CEILING FAN <br />W <br />(1) PHONE LINE, (1) DATA PORT <br />S.D <br />C.M <br />OWNER'S Sl'T� ITE <br />1 <br />/ ROUGH -IN FOR / <br />/ OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />_ u r, <br />i <br />PA CAFE <br />`\ <br />I / <br />I <br />I <br />I <br />I <br />I <br />I <br />I ` <br />I )` <br />FAMILY R M <br />/ <br />I G <br />ROUGH -IN FOR <br />I <br />OPT. CLG. FAN/ <br />LIGHT PRE -WIRE <br />I <br />U.C. OUTLET <br />I FOR DW <br />I <br />U.C. OUTLET <br />I +� <br />I <br />I —GFI <br />GFI C—---------- GF!! <br />i I I O <br />I D.W. I <br />i IL — — —J <br />INK / DIS <br />-ENDANT AS <br />■ ■ <br />11■ � � <br />_SPECS <br />I i mm Rm no 1 <br />1-,� ■ <br />��11111111111111111111111111111111111111111111E1111111111111111111� <br />RECEPT. <br />FOR ALARM <br />SYSTEM <br />■ <br />VERIFY METER <br />LOCATION WITH <br />BUILDER H. <br />IRRIGATION <br />VERIFY LOCATION GFI @ 44" A.F.F. <br />W H ELECTRICAL PANEL <br />O I <br />I <br />I <br />I <br />2 CAR GARAGE <br />I <br />I <br />GFI FOR <br />GAR. DOOM <br />GFI I <br />GFI @ 44" <br />A.F.F. <br />I <br />I <br />I h I <br />I <br />I <br />I <br />IlI 11 1 <br />L--------- <br />GFI @ 44" <br />A.F.F. <br />1 <br />111 �� ��� JIIIIIIIIIIIIIIIIIIIIIIIIIII <br />S.D. ---�"� _ S.D. <br />M <br />G <br />I <br />OPT. I <br />REF I ,i NN � FI <br />BEDROOM 2 �Z S.D. -- - <br />/�/ BEDROOM 3 1 \ BEDROOM 4 <br />BATH <br />GFI /� I ' <br />ROUGH -IN FOR <br />OUGH-IN FOR �/ I I — — ` \ OPT. CLG. FAN/ <br />I OPT. CLG. FAN/ I <br />LIGHT PRE -WIRE I — \ LIGHT PRE -WIRE <br />ROUGH -IN FOR I <br />OPT. CLG. FAN/ I \ <br />/ LIGHT PRE-WIREEl <br />\ ` <br />ELECTRICAL PLAN - ELEV-Al <br />SCALE: %4'=1'-0" <br />0 <br />N <br />0 <br />CV <br />0 <br />0 <br />To the best of the Engineer's knowledge, information and belief, <br />the structural plans and specifications contained <br />within these <br />drawings comply with the 2017 Florida Building Code - <br />Residential 6th Edition. Engineer's signature and seal is only for <br />the structural engineering portions of the drawing pages bearing <br />Engineer's signature and seal. <br />[- <br />Q <br />oo N (O <br />m <br />Vq <br />MN N <br />NN2Sz <br />LO <br />0 LLYY <br />VHa <br />(h�— <br />LLM <br />LL Jdz <br />as <br />Iff <br />rma <br />- <br />oZ0Wa)0 <br />00 <br />NpM <br />Co <br />W <br />ZNU❑❑❑Q <br />ET <br />a <br />a <br />M Z <br />NO$ <br />��CLL <br />W <br />� <br />z o <br />cc o <br />cc QQ(0 <br />izz <br />z O Q <br />Q� <br />J � <br />d N <br />M <br />N <br />rC <br />z <br />o <br />Q) <br />t` <br />4C+ <br />T Cn Y <br />fQ w 0 <br />n <br />U <br />0 <br />N <br />LJJ � <br />c <br />�N <br />� <br />� <br />� o <br />v <br />W <br />all <br />` e <br />o g <br />_ :F: <br />U ) N <br />e <br />Q � o <br />o <br />w <br />M. <br />cop <br />J <br />Z <br />Z <br />6 <br />1 <br />LL <br />Q E <br />o <br />K <br />z o <br />oa <br />NONE <br />S< <br />O E <br />N <br />az <br />w o <br />Q <br />aZ <br />r w <br />L <br />(� <br />N <br />o <br />OI U <br />m <br />F O <br />O <br />Z <br />- <br />J <br />Nm <br />¢w <br />2. <br />ONE <br />to > <br />on <br />N 7 <br />Q <br />Q <br />p� <br /><0 <br />Z Z <br />ao <br />�w <br />G <br />Q; <br />;o <br />o <br />CO <br />ct <br />z¢ <br />a �- <br />0� <br />c M <br />0 <br />N <br />L <br />� <br />m <br />m <br />^, <br />W <br />co <br />c� <br />N <br />.! <br />C:) <br />11 <br />C o <br />a <br />m <br />2 <br />I� <br />O N <br />N <br />r <br />J <br />Ln <br />r <br />2 N <br />r <br />N <br />o <br />Z <br />CU <br />Z <br />E O <br />cE <br />0 cc <br />� <br />a <br />U <br />Q O <br />-� <br />JOB <br />NO: <br />20-3566 <br />SCALE : <br />AS NOTED <br />SHEET NO. <br />4 <br />